MOUNTING 

Orientation 

This fixture may be mounted in any position, provided there is adequate room for ventilation 

It is important never to obstruct the fan or vents pathway.   

When selecting installation location, take into consideration lamp replacement access and routine maintenance.   

Safety cables must always be used. 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or 

restricted ventilation. 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer 

or his service agent or a similar qualified person in order to avoid a hazard. 

Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the 

light will not fall from the truss, use the safety cable go through the truss and bracket of the light as a supporting, to 

avoid the light to fall down. There is no entrance to the work area during mounting. Periodically check if the safety 

cable has fretted away or clamp is loosened. We will not take any responsibility for damages caused by a  badly 

installed unit. 

 

Power Supply and Signal Cable Connection 

1. Mains Power connection 

The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage 

and frequency are accordance with the power supply. The required input voltage and frequency are: 100-240Vac – 

50-60Hz 

We suggest that every light has an independent switch so that you can turn on or turn off the light randomly. 

Note: the ground wire (yellow/green double-color wire) must be safely connected, the electrical installation must be 

in accordance with the related standards

 

CAUTION

: When installing the device, make sure there is no highly inflammable material within a distance of 

min.5m! 

 

2. Connection of Signal Cable 

You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light. 

Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to 

the IN socket of the next light. Ordinal to connect all the lights as below: 

IN

O U T

IN

O U T

O U T

IN

1

2

3

D

M

X

  IN

DM
X  O

UT

 

The connection between the output of master and input of product, it’s available to use the 3 pins XLR cable which 

provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, 

and connect to the DMX input of second slave light from the DMX output of the first master light, analogously, till 

connected all the slave lights, and insert the last connector to the output of the final light. (Notice: the diameter of 

core of every cable should be 0.5mm at least, double core shelter cable should be used).The signal connecting must 

use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each 

other or connect to the connector. 

 

A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with a 

120Ω resistor between the pin 2 and pin 3 of the XLR connector 

 

 

 

Содержание 15-1878

Страница 1: ...R RE E D DM MX X C CO OM MB BI IN NE E A A L LE ED D W WA AS SH H L LA AS SE ER R R RO OU UG GE E V VE ER RT T D DM MX X G GE ES ST TE EU UE ER RT TE ER R K KO OM MB BI IN NI IE ER RT TE ER R L LE ED...

Страница 2: ...suffer a life threatening electric shock when touching live wired 2 Never look directly into the light source as sensitive persons may suffer an epileptic shock 3 Please be aware that damages caused...

Страница 3: ...We suggest that every light has an independent switch so that you can turn on or turn off the light randomly Note the ground wire yellow green double color wire must be safely connected the electrical...

Страница 4: ...5 Auto program 5 Au 6 Auto program 6 Au 7 Auto program 7 Sound So 1 Sound program 1 So 2 Sound program 2 So 3 Sound program 3 So 4 Sound program 4 So 5 Sound program 5 So 6 Sound program 6 So 7 Sound...

Страница 5: ...0 255 Rainbow Group effect with strobe From slow to fast CH2 0 9 No function 10 19 Red 20 29 Green 30 39 Blue 40 49 White 50 59 Amber 60 69 UV 70 79 Red Green 80 89 Red Blue 90 99 Green Blue 100 109 G...

Страница 6: ...9 No function 10 19 Red 20 29 Green 30 39 Blue 40 49 White 50 59 Amber 60 69 UV 70 79 Red Green 80 89 Red Blue 90 99 Green Blue 100 109 Green Amber 110 119 Blue Amber 120 129 Green White UV 130 139 R...

Страница 7: ...19 Auto DMX From slow to fast 120 255 Sound DMX From slow to fast IR CONTROLLER BLACK OUT Mode 1 Press BLACK OUT to switch out the lights in the current mode Press again to return to the last mode AUT...

Страница 8: ...ested to use the high quality professional glass detergent and soft cloth to clean the light It s not allowed to use alcohol or chemical solvent When the light doesn t work please check if the fuse is...

Страница 9: ...e commutateur doit rester facilement accessible Des protections lentilles ou crans ultraviolets doivent tre remplac s lorsqu ils sont visiblement endommag s au point qu ils perdent leur efficacit p ex...

Страница 10: ...s la structure et l trier Personne ne doit se trouver en dessous de la zone de travail pendant l installation Nous d clinons toute responsabilit pour des dommages et blessures survenus suite une chute...

Страница 11: ...n 2 So 3 Programme activ par le son 3 So 4 Programme activ par le son 4 So 5 Programme activ par le son 5 So 6 Programme activ par le son 6 So 7 Programme activ par le son 7 Speed SP 1 SP9 R glage de...

Страница 12: ...10 255 Effet groupe arc en ciel avec strobo lent rapide CH2 0 9 Pas de fonction 10 19 Rouge 20 29 Vert 30 39 Bleu 40 49 Blanc 50 59 Ambre 60 69 UV 70 79 Rouge Vert 80 89 Rouge Bleu 90 99 Vert Bleu 100...

Страница 13: ...19 Rouge 20 29 Vert 30 39 Bleu 40 49 Blanc 50 59 Ambre 60 69 UV 70 79 Rouge Vert 80 89 Rouge Bleu 90 99 Vert Bleu 100 109 Vert Ambre 110 119 Bleu Ambre 120 129 Vert Blanc UV 130 139 Rouge Ambre UV 14...

Страница 14: ...Pressez BLACK OUT pour couper la lumi re du mode en cours Pressez une seconde fois BLACK OUT pour revenir au mode en cours Mode AUTO Le bouton AUTO permet de lancer l un des programmes auto interne 1...

Страница 15: ...ar an au moyen d un aspirateur Si la lampe ne fonctionne pas v rifiez si le fusible a saut Si c est le cas remplacez le fusible par un neuf qui pr sente exactement les m mes caract ristiques technique...

Страница 16: ...esch digt sind dass ihre Wirksamkeit nicht mehr gegeben ist z B durch Br che oder tiefe Kratzer Die Lampe muss ausgewechselt werden wenn sie besch digt oder durch die Hitze verformt ist ACHTUNG 1 Seie...

Страница 17: ...age darf sich niemand unter dem Montageplatz aufhalten Pr fen Sie regelm ig ob das Sicherheitskabel noch gut fest sitzt und sich keine Schraube gel st hat Wir bernehmen keine Haftung f r Personen und...

Страница 18: ...langaktiviertes Programm 3 So 4 Klangaktiviertes Programm 4 So 5 Klangaktiviertes Programm 5 So 6 Klangaktiviertes Programm 6 So 7 Klangaktiviertes Programm 7 Speed SP 1 SP9 Geschwindigkeitsregelung f...

Страница 19: ...210 255 Rainbow Gruppeneffekt mit Stroboskop von langsam schnell CH2 0 9 Unbelegt 10 19 Rot 20 29 Gr n 30 39 Blau 40 49 Weiss 50 59 Amber 60 69 UV 70 79 Rot Gr n 80 89 Rot Blau 90 99 Gr n Blau 100 10...

Страница 20: ...elegt 10 19 Rot 20 29 Gr n 30 39 Blau 40 49 Weiss 50 59 Amber 60 69 UV 70 79 Rot Gr n 80 89 Rot Blau 90 99 Gr n Blau 100 109 Gr n Amber 110 119 Blau Amber 120 129 Gr n Weiss UV 130 139 Rot Amber UV 14...

Страница 21: ...er Motors von langsam schnell CH14 0 9 Unbelegt 10 119 Auto DMX von langsam schnell 120 255 Sound DMX von langsam schnell IR FERNBEDIENUNG BLACKOUT Licht ein Aus in der gew hlten Betriebsart AUTO W hl...

Страница 22: ...rung Die Sicherung nur durch eine gleichwertige Sicherung ersetzen und das Ger t erneut einschalten Bitte beachten Sie dass alle Reparaturen nur von einem Fachmann vorgenommen werden d rfen TECHNISCHE...

Отзывы: