• Place the feeder tube with filter deep inside the full fluid tank (Figure 1-D). Use definitely water
based liquid of good quality;
• Plug mains power cord from the faze machine into appropriate power supply socket. Wait about
75 seconds for heating element to heat up;
• Use LCD display for operating control, or connect DMX controller for setting; or firmly attach the
remote control mechanism to socket (Figure 1-K) on the rear of the unit.
• Refer to your controller manual for operation details (Appendix A)
.
DMX CONNECTOR PIN ASSIGNMENT
The machine provides a 3- or 5-pin XLR connector for DMX connection. The diagram below indi-
cates pin assignment information.
5 pin XLR
3 pin XLR
1. Ground
1. Ground
1. Ground
1. Ground
2. Cold
2. Cold
2. Cold
2. Cold
3. Hot
3. Hot
3. Hot
3. Hot
4. N/A
4. N/A
5. N/A
5. N/A
XLR Pin Configuration
Pin 1= Ground
Pin 2= Data Compliment
(negative)
Pin 3= Data True (positive)
Pin 4= No use
Pin 5= No use
XLR Pin Configuration
Pin 1= Ground
Pin 2= Data Compliment
(negative)
Pin 3= Data True (positive)
FUNCTIONS OF THE BUTTONS
MENU: Function switching button; then have the numerical value changed by using the UP and
DOWN buttons.
A.xxx: Setting of DMX address. Range of address value: address=001~512. Press ”UP” or “Down”
1.5 seconds can change value continuously and fast, press UP/DOWN at the same time to set the
value back to 1.
P.xxx: Setting output of timing fogging and continuous Fogging (Puff Volume=5~100%).
F.xxx: Setting fan speed of timing fogging and Continuous Fogging (Fan=5~100%).
t.oFF/t. on: Setting Timer ON/OF, switching by UP and DOWN buttons