AFRISO VA-ALERT Скачать руководство пользователя страница 2

AFRISO EMA AB

 • Kilvägen 2, SE-232 37 Arlöv • Phone +46-(0)40-92 20 50 • [email protected] • www.afriso.se

2

VA-ALERT

 

Full Tank Alarm for sewage tanks • Installation instructions

  Subject to design modifications..

VA-ALERT

      Alarm unit must 
not be disposed with 
household garbage,
but should be handled as
electronic waste.

   

Safety /

   

important to consider

•  Carefully read the installation manual 

 

 

before assembly

•  Alarm Device may only be installed in dry  

 

  indoor areas.
•  The equipment may only be used for indica-   
  tion of high level alarms in sewage tanks or    
  water tanks.
•  Can not be used in connection with oil or  

 

  petrol! Nor in hazardous areas!
•  If the tank is to be below ground, be sure  
  that the sensor can be accessed simply by  
  installing a manhole, etc. This is to avoid 
   having to dig to access the sensor for any    
  future sensor replacement.
•  The sensor is available with 2 or 10 m cable.  
  If sensor cable needs to be extended: Use    
  RKK 2 x 0.75 mm

2

. Do not use multiconductor 

  cable (for pump control signals or the like).    
 

See more in ”Splicing” on page 3.

Function Description

VA-ALERT for sewage tanks is a unit with 
conductive probe that use AC technology 
for the sensor. The unit is designed to be 
mounted directly onto a wall indoors and is 
powered by 3 AA batteries with a life expec-
tancy of at least 3 years.

VA-ALERT has an internal relay which allows 
connection to alarm lamp or SMS-alarm unit.

VA-ALERT is used for cisterns / tanks con-
taining electrically conductive liquids. Alarm 
is given when the contents of the tank has 
reached to the two electrodes of the sensors 
lower part. The unit has built-in warning for 
low battery voltage, which warns of battery 
replacement in due time before the battery is 
exhausted (about 3-6 months before).

Components parts

VA-sensor

VA-ALERT

ALARM

NORMAL

+

!

Содержание VA-ALERT

Страница 1: ...friso se VA ALERT ALARM NORMAL CONTENT Function Description 2 Component Parts 2 Safety regulations 2 Installation 3 Function Testing 4 Operation 5 Troubleshooting 6 Specifications 7 Options accessories 7 Declaration 8 Keep this manual for future use VA ALERT Full Tank Alarm for sewage tanks ...

Страница 2: ... for any future sensor replacement The sensor is available with 2 or 10 m cable If sensor cable needs to be extended Use RKK 2 x 0 75 mm2 Do not use multiconductor cable for pump control signals or the like See more in Splicing on page 3 Function Description VA ALERT for sewage tanks is a unit with conductive probe that use AC technology for the sensor The unit is designed to be mounted directly o...

Страница 3: ...75 mm2 to an appropriate location for the alarm device The interconnection of the signal line and the sensor is made using the supplied coupling piece Do not connect the signal line in a multiconductor cable together with other signals 230 V pump control etc Fix the joint location with electrical tape insulating tape or equivalent Protect the power cord in the ground with conduit or the like NOTE ...

Страница 4: ... the battery holder calculated life span about 3 5 years Back side of the front to the VA ALERT Wiring on terminal When using external power no batteries should be used Mains batt ery eliminator 12 VAC or 12 VDC is optional Insert the batteries into the holder and verify that the polarization is correct see symbols in the battery holder The unit will now give a quick flash about every two seconds ...

Страница 5: ...eration no alarm Normal operation no action Green LED Normal flashes faster in network operation Tank full Order emptying of the tank The built in buzzer will sound and the red LED Alarm flashes every second To reset press the Mute button Low Battery Voltage on battery Replace batteries with new AA The built in buzzer sounds the red batteries 3 pcs of alkaline type LED Alarm and the green LED Norm...

Страница 6: ...rm the red LED Check that the sensor is properly Alarm does not flash connected and that there is no cable break If necessary short circuit with a cable stub or cable clamp and alarm shall be given Sensor in air but the unit gives an alarm Check that no moisture has entered red LED in the the cable joint Alarm flashes and the buzzer sounds If necessary disconnect the sensor cable from terminals 3 ...

Страница 7: ...iple Conductive Power Supply 3 x AA batteries alt mains adapter transformer 12 VAC or 12 VDC Life expectancy when on battery At least 3 years Measurements 62x112x32 mm WxHxD Weight Approx 100 g Approx 165 g incl batteries Temperature range 0 40 C in operation 25 50 C during storage Relay contacts Voltage free Um 50 VAC 75 VDC Im 2 A Degree of protection IP 42 Mains battery eliminator 12 VAC or 12 ...

Страница 8: ...facturer Afriso Ema AB Kilvägen 2 SE 232 37 Arlöv Product Full Tank Alarm for sewage tanks of the type VA ALERT Technical Details DC 4 5 V IP42 The above mentioned product is in accordance to the following European directives and standards Directive for electromagnetic compatibility EN 61000 6 4 2007 EN 61000 6 1 2007 Low Voltage Directive EN 61010 1 2010 Sign Urban Nilsson Technical Manager Date ...

Отзывы: