13
Decommissioning, disposal
EN
KSG Magnum
8
Decommissioning, disposal
Dispose of the product in compliance with all applicable directives, standards
and safety regulations.
1. Dismount the product (see chapter "Mounting", reverse sequence of
steps).
2. Dispose of the product.
9
Returning the device
Get in touch with us before returning your product.
10
Warranty
See our terms and conditions at www.afriso.com or your purchase contract
for information on warranty.
Problem
Possible reason
Repair
Pointer of pressure
gauge below green
range
System pressure too
low
Fill liquid into the system
until the pointer of the
pressure gauge is in the
green range
Pointer of the pressure
gauge again below
green range after filling
of the system
Leak in system
Check the system for
leaks
Other malfunctions
-
Contact the AFRISO
service hotline