background image

 

7

 

RR-94845SL 

VIDEO INPUT / OUTPUT CONNECTIONS 

Video input and output connections are located on the rear of the 980 series units. A BNC 
connector is provided for each channel. The video inputs are connected to an appropriate 75

 

baseband video source such as a camera or a video recorder output. The 75

 video outputs 

can be looped through typical baseband video inputs of switchers, recorders and other 
equipment as required. For proper operation, the outputs must be terminated with 75

. For 

optimum performance the video cables should be the shortest length of coax practical. 

 

The location of a video input to the RT-94845SL will be mirrored as a video output at the RR-
94845SL. For example, the Channel 2 video input on the RT-980-1550 will become the Channel 
2 video output on the RR-980-1550 after traveling across the fiber infrastructure. 

 
ETHERNET  DATA INPUT / OUTPUT CONNECTIONS 

A RJ45 connector is used to connect UTP Ethernet data to the 45 series units. 

 
MDI / MDIX Switch 

All Ethernet equipment is designed with a MDI interface port or a MDIX interface port. The terms 
MDI and MDIX refer to a specific orientation of the transmit data signal and the receive data 
signal on the RJ45 connection to the unit. Some units have a switch built into them that allows 
you to choose the port to be either MDI or MDIX. Other units can auto-configure to either speed. 
Typically, a computer or terminal is wired as an MDI port connection and a network hub or 
switch is wired as an MDIX connection. The MDI configured device is connected to the MDIX 
device with a straight through Ethernet patch cable. Whenever a connection from one MDI 
device to another MDI device is required, the use of a crossover cable is required to reorient the 
signals, making the first device appear as if it was configured as MDIX. The RTX-45-1490 and 
RRX-45-1490 are shipped in the MDI configuration. Therefore, when connecting to a MDI 
configured device a crossover cable should be used. In the event the proper cable is not 
available, an external switch is provided at the rear of the 45 series unit for reconfiguring the 
unit as a MDIX port. 

If the 45 series unit is connected to an auto-configure device, it is not 

necessary to change the MDI / MDIX switch.

 

Содержание RR-94845SL

Страница 1: ... Copyright 2007 American Fibertek Inc 0411JD Instruction Manual RT 94845SL RR 94845SL Forty Eight Channel Video Multiplexer With Bi directional Ethernet Data ...

Страница 2: ... Components 5 Power Connections 6 Fiber Connections 6 Video Input Output Connections 7 Ethernet Data Connections 7 RT 980 Series Status LED Indicators 8 RTX 45 1490 Status LED Indicators 9 RR 980 Series Status LED Indicators 10 RRX 45 1470 Status LED Indicators 11 Warranty Service Information 12 ...

Страница 3: ...multiplexes each group into a high speed serial data stream The first group s serial data stream modulates a laser at 1510nm wavelength The second group s serial data stream modulates a laser at 1530nm wavelength This pattern is repeated for group s three through six using wavelengths 1550nm through 1610nm respectively A Course Wave Division Multiplexer CWDM combines these six wavelengths along wi...

Страница 4: ...k panel next to the PSR 2 power supply followed by the RTX 45 1490 data card The lowest wavelength video card the RT 980 1510 continues the configuration which ends with the highest wavelength card the RT 980 1610 at the left side of the rack Following this configuration allows the fiber port on the back of the 980 series card to best line up with its associated port on the CDWM unit Use a small s...

Страница 5: ...ed MRX CWDM 8 Mounting procedures and recommendations should follow those used for the RT 94845SL RR 94845SL POWER SOURCE Power to the 980 series and 45 series rack cards is supplied by the subrack Please refer to the SR 20 and PSR 2 instructions for further details The CDWM unit is a passive device which does not require any power source POWER CONNECTION Power is supplied to the individual 980 se...

Страница 6: ...on the 980 series unit to which that port is attached The top port of the RTX 45 1490 connects to the 1470nm port on the CWDM The bottom port of the RTX 45 1490 connects to the 1490nm port on the CWDM Follow the drawing below for the proper connections of the fiber patchcords RT 94845SL RR 94845SL FIBER CONNECTIONS The fiber optic connections on the RR 94845SL are similar to those for the RT 94845...

Страница 7: ... with a MDI interface port or a MDIX interface port The terms MDI and MDIX refer to a specific orientation of the transmit data signal and the receive data signal on the RJ45 connection to the unit Some units have a switch built into them that allows you to choose the port to be either MDI or MDIX Other units can auto configure to either speed Typically a computer or terminal is wired as an MDI po...

Страница 8: ...id in installation and troubleshooting VIDEO 1 THROUGH VIDEO 8 A bi color LED indicator is provided for the each of the eight video inputs to the RT 980 series transmitters Video status associated with each of these LED s is summarized below Video Presence LED Video Status Green Proper Input Video Present Red Input Video Not Detected ...

Страница 9: ...uplex Off Data Packets Not Detected POWER A green LED indicator monitors the presence of DC voltage into the RTX 45 1490 from the subrack DC voltage status associated with this LED is summarized below Power Indicator DC Input Voltage Status Green DC Voltage Present Off Check Subrack Power Supply FIBER ACTIVITY A green LED indicator monitors the presence of any data signals into the RTX 45 1490 fro...

Страница 10: ...nal that is being received at the RR 980 series unit from video channels one through eight of its corresponding RT 980 series unit AC power and optical input status associated with this LED are summarized below Optical Level Indicator AC Power Status Optical Status Green On Proper Optical Input Power Present Red On Optical Input Not Detected Off Off Check Power Supply Input SYNC A bi color LED ind...

Страница 11: ...uplex Off Data Packets Not Detected POWER A green LED indicator monitors the presence of DC voltage into the RRX 45 1470 from the subrack DC voltage status associated with this LED is summarized below Power Indicator DC Input Voltage Status Green DC Voltage Present Off Check Subrack Power Supply FIBER ACTIVITY A green LED indicator monitors the presence of any data signals into the RRX 45 1470 fro...

Страница 12: ...R THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty...

Отзывы: