AFi RR-915C-SL Скачать руководство пользователя страница 4

 

4

DATA INPUT / OUTPUT CONNECTIONS 

Data input and output connections are made via the top (DATA 1) terminal block on the back of the 
unit. See the drawings below for proper orientation of input and output connections. Please note that 
the far right pin on each connection drawing corresponds with the far right pin when looking at the 
terminal block from the back of the unit. 

 

TYPICAL SYSTEM DATA CONNECTIONS 

The RS422 or RS485 four wire interconnection between the RR-915C-SL and the copper device to 
which it is attached is based on industry standard EIA terminology for the transmission of electronic 
data signals. Using this terminology, the driver of an electronic signal is labeled TX or Data Out. 
Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard, 
the Data Out of the copper device is connected to the Data In of the RR-915C-SL. The plus terminal of 
the copper device is connected to the plus terminal of the RR-915C-SL and the minus is connected to 
the minus. The reverse flow of data from the RR-915C-SL to the copper device follows the same 
pattern. Not all manufactures follow standard EIA terminology. Consult the installation instructions for 
your copper device if you are unsure which two wires are the drive (data out) wires and which two wires 
are the receive (data in) wires.  

 
CONTACT CLOSURE INPUT / OUTPUT CONNECTIONS 

Contact Closure input and output connections are made via the bottom (DATA 2) terminal block on the 
back of the unit. See the drawing below for proper orientation of input and output connections. Please 
note that the far right pin on the connection drawing corresponds with the far right pin when looking at 
the terminal block from the back of the unit. 

 

DATA CONFIGURATION 

NOTE: This unit is shipped in the following default configuration.  
 

Channel 1: RS485 (4 wire) data 
Channel 2: Contact Closure (dry) 

For other configurations of channel 1, please refer to the drawing below for changes to the default 
switch settings. These configuration switches are located on the bottom of the unit and can be modified 
without opening the unit.  

 

Содержание RR-915C-SL

Страница 1: ...Copyright 2011 American Fibertek Inc 0812JPK Instruction Manual RR 915C SL Video Receiver With Bi directional Multi Protocol Data And Bi directional Contact Closure...

Страница 2: ...nsmitter with bi directional data over one multimode fiber optic cable The RR 915C SL multiplexes up to two data signals into a high speed serial data stream This serial data stream modulates a laser...

Страница 3: ...lane connector The RR 915C SL can be inserted into the subrack or removed from the subrack with power applied to the backplane FIBER CONNECTION The fiber optic connection is made via a ST connector lo...

Страница 4: ...rminal of the RR 915C SL and the minus is connected to the minus The reverse flow of data from the RR 915C SL to the copper device follows the same pattern Not all manufactures follow standard EIA ter...

Страница 5: ...ws multiple receiver devices to reside on the same wire pair The software must dictate a protocol that allows only one device to transmit at any one time to prevent data crashes In many cases the syst...

Страница 6: ...ata Flow Not Detected DATA 1 RX A green LED indicator is provided to monitor the data coming in from the fiber through the RR 915C SL and out onto the electrical interface The intensity of this indica...

Страница 7: ...SL or the RT 915C SL DC power and optical input status associated with this LED are summarized below Optical Level Indicator DC Power Status Optical Status Green On Proper Optical Input Power Present...

Страница 8: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...

Отзывы: