AFi RR-913 Скачать руководство пользователя страница 7

 

7

RR-913 STATUS INDICATORS 

The RR-913 receiver provides the following LED status indicators to aid in installation and 
troubleshooting: 

 
DATA TX/RX INDICATORS 

DATA TX and DATA RX indicators are provided to monitor each of the three available data channels. 
DATA 1 TX and DATA 1 RX correspond with DATA CH 1 input/output. Indicators for Channel 2 and 
Channel 3 are also provided. An explanation follows for these DATA TX and DATA RX indicators.

 

 

DATA TX 

A green LED indicator is provided to monitor the data coming in from the electrical interface, through 
the RR-913, and out onto the fiber. The intensity of this indicator will vary with input data patterns, 
however in typical applications it will cycle on and off as data is transmitted. Data transmitted status 
associated with this LED is summarized below. 
 

DATA TX LED 

Data Status  

Green 

Data Flow Present  

Off 

Data Flow Not Detected 

 
DATA RX 

A green LED indicator is provided to monitor the data coming in from the fiber, through the RR-913, and 
out onto the electrical interface. The intensity of this indicator will vary with input data patterns, however 
in typical applications it will cycle on and off as data is received. Data received status associated with 
this LED is summarized below. 
 

DATA RX LED 

Data Status  

Green 

Data Flow Present  

Off 

Data Flow Not Detected 

 
VLI 

A bi-color LED indicator is provided for the video output from the RR-913. DC power and video status 
associated with this LED is summarized below. 
 

Video Presence LED 

DC Power Status 

Video Status 

Green 

On  

Proper Output Video Present 

Red 

On 

Output Video Not Detected 

Off 

Off 

Check Power Supply 

 
OLI 

A bi-color LED indicator monitors the optical input power of the data signal that is being received at the 
RR-913 from the MT-913 or the RT-913. DC power and optical input status associated with this LED 
are summarized below. 
 

Optical Level Indicator 

DC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply 

 

Содержание RR-913

Страница 1: ...Copyright 2005 American Fibertek Inc 0824JD Instruction Manual RR 913 Video Receiver With Bi directional Multi Protocol Data...

Страница 2: ...Source 4 Power Connection 4 Fiber Connection 4 Video Input Connection 4 Data Input Output Connections 5 Typical System Data Connections 5 Data Configuration 5 RS485 Data Signals 6 Offset Bias RS485 6...

Страница 3: ...section for changes to the default switch settings Channel 1 RS422 data Channel 2 RS485 4 wire or Manchester data Channel 3 RS232 data The RR 913 is designed to operate with the MT 913 or RT 913 video...

Страница 4: ...kplane connector The RR 913 can be inserted into the subrack or removed from the subrack with power applied to the backplane FIBER CONNECTION The fiber optic connection is made via a ST connector loca...

Страница 5: ...Data Out of the copper device is connected to the Data In of the RR 913 The plus terminal of the copper device is connected to the plus terminal of the RR 913 and the minus is connected to the minus T...

Страница 6: ...mitter devices to go into a high impedance Hi Z state This allows multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to trans...

Страница 7: ...indicator is provided to monitor the data coming in from the fiber through the RR 913 and out onto the electrical interface The intensity of this indicator will vary with input data patterns however...

Страница 8: ...ts have been tampered with This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract EXCEPT FOR THE FOREGOING...

Отзывы: