AFi MT-915D Скачать руководство пользователя страница 7

 

7

VLI 

A bi-color LED indicator is provided for the video input to the MT-915D. DC power and video status 
associated with this LED is summarized below. 
 

Video Presence LED 

DC Power Status 

Video Status 

Green 

On  

Proper Input Video Present 

Red 

On 

Input Video Not Detected 

Off 

Off 

Check Power Supply 

 
OLI 

A bi-color LED indicator monitors the optical input power of the data signal that is being received at the 
MT-915D from the MR-915D or the RR-915D. DC power and optical input status associated with this 
LED are summarized below. 
 

Optical Level Indicator 

DC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply 

 
SYNC 

A bi-color LED indicator is provided to monitor the proper serialization of the electrical data stream 
through the MT-915D and out onto the fiber. DC power and sync status associated with this LED is 
summarized below. 
 

Sync LED 

DC Power Status 

Sync Status 

Green 

On  

Proper Data Stream Serialization Present 

Red 

On 

Data Stream Serialization Not Detected 

Off 

Off 

Check Power Supply 

 
RANGE 

A bi-color LED indicator is provided to monitor the maximum video input level to the 
MT-915D. DC power and video status associated with this LED is summarized below. 
 

Range LED 

DC Power Status 

Video Status 

Green 

On  

Input Video Maximum < 1.4Vpp 

Red 

On 

Input Video Maximum > 1.4Vpp 

Off 

Off 

Check Power Supply 

 

Содержание MT-915D

Страница 1: ...Copyright 2005 American Fibertek Inc 1109JD Instruction Manual MT 915D Video Transmitter With Bi directional Multi Protocol Data Bi directional Contact Closure And Remote Diagnostic Interface...

Страница 2: ...i directional data over one multimode fiber optic cable The MT 915D multiplexes a single video input signal along with up to two data signals into a high speed serial data stream This serial data stre...

Страница 3: ...SUPPLY ONLY This unit requires a 12VDC power source with a current rating of 1 25 amps for proper operation The DC input is diode protected In the USA and in Canada an American Fibertek PS 12D is supp...

Страница 4: ...ignals Using this terminology the driver of an electronic signal is labeled TX or Data Out Correspondingly the receiver of an electronic signal is labeled RX or Data In Following this standard the Dat...

Страница 5: ...transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to transmit at any one time to prevent data crashes In many cases the system head...

Страница 6: ...Data Flow Not Detected DATA 1 RX A green LED indicator is provided to monitor the data coming in from the fiber through the MT 915D and out onto the electrical interface The intensity of this indicat...

Страница 7: ...n Proper Optical Input Power Present Red On Optical Input Not Detected Off Off Check Power Supply SYNC A bi color LED indicator is provided to monitor the proper serialization of the electrical data s...

Страница 8: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...

Отзывы: