background image

INSTRUCTIONS - Model 5621SD -  20 TON LOW PROFILE AIR/HYDRAULIC BOTTLE JACK

 

 

 

 

 

2.5  For best performance and longest life, replace the complete jack oil at least once per year: W ith the ram 

fully lowered, remove the oil filler plug, lay the jack on its side and drain the oil into a suitable container, then 
fill with high quality hydraulic jack oil as described in 2.4, reinstall the filler plug. 

NOTE: 

Dispose of hydraulic oil in accordance with local regulations. 

2.6 It is recommended that an annual inspection be done by qualified technicians. 

 

 

 
 
 
 

3.TROUBLESHOOTING

 

Symptom 

Possible Causes 

Corrective Action 

Jack will not lift load 

Release valve not tightly closed 
Overload condition 
Air supply inadequate 
Air trapped in system 

Close release valve firmly 
Remedy overload condition 
Ensure adequate air supply 
Purge away air from system 

Jack will lift, but will not maintain 
pressure 

Release valve not tightly closed 
Overload condition 
Hydraulic unit malfunction 

Close release valve firmly 
Remedy overload condition 
Contact your local service center 

Will not lower after unloading 

Reservoir overfilled 
Linkages binding 

Drain oil to proper level 
Clean and lubricate moving parts 

Poor lift performance 

Hydraulic oil level low 
Air trapped in system 

Add oil to proper level 
Purge away air from system 

Will not lift to max height 

Hydraulic oil level low 

Add oil to proper level 

 
 

Capacity 

Min Height 

Ram Travel 

Screw Adj. 

Max Height 

Air Pressure 

Air Inlet Fitting 

20ton 

7.01” 

3.35” 

2.40” 

12.76” 

110-120 Psi 

1/4" NPT 

Содержание 5621SD

Страница 1: ...r owner or his designee making sure that the operator comprehends their contents A copy of these instructions warnings shall be retained for future reference INSPECTION Visual inspection shall be made before each use of this equipment checking for abnormal conditions such as cracked welds leaks damaged loose or missing parts This equipment shall be removed immediately from service if it is believe...

Страница 2: ...ower the load by turning the release valve counterclockwise use the slotted end of the handle in extremely small increments then lower the extension screw by turning it clockwise as needed and remove the jack WARNING Dangerous dynamic shock loads are created by quick opening and closing the release valve when the load is being lowered The resulting overload may cause hydraulic system failure which...

Страница 3: ...closed Overload condition Air supply inadequate Air trapped in system Close release valve firmly Remedy overload condition Ensure adequate air supply Purge away air from system Jack will lift but will not maintain pressure Release valve not tightly closed Overload condition Hydraulic unit malfunction Close release valve firmly Remedy overload condition Contact your local service center Will not lo...

Страница 4: ...damaged by accident overload misuse or abuse nor does it apply to any product which has been modified altered or used with special attachments other than those expressly recommended by AFF There are no other warranties express or implied and Seller specifically disclaims any warranty of merchantability or of fitness for any particular purpose The Seller s sole obligation which shall represent the ...

Отзывы: