Pos.
Life phases
Description of hazard
Risk
assessment
Measures to reduce risk
PL
4
Operation
Pacemakers may be
affected by permanent
magnets.
S = S2
F = F1
O = O1
A = A1
Erg = 3
With the safeguard, a
safety distance of
0.2 m from the
pacemaker must be
guaranteed
--
5
Operation
Risks of limb crushing,
bruising and broken
bones due to accessing
the travel range of the
moving device.
S = S2
F = F2
O = O2
A = A1
Erg = 4
Operation of the device
behind a
safeguard to ensure
that access to the
travel range is denied.
S = S2
F = F1
P = P1
PL = c
6
Operation,
Maintenance
Repairs
Burning of the skin due
to surface temperatures
of up to 60°C.
S = S1
F = F1
O = O2
A = A1
Erg = 1
1.
Avoid direct contact
when the device is in
operation.
2.
Allow the device to cool
down before carrying
out maintenance work,
or protect the skin
accordingly (gloves,
long clothing...)
--