3.4
Power supply
WARNING
▪
Any work performed on the electrical supply may only be
performed by trained, authorised, qualified personnel!
▪
The power supply must be protected by an FI switch (pro-
vided by the customer).
▪
The linear feeder may only be operated with the power sup-
ply specified on the name plate.
The control device IRG1-S is used for the activation of the linear feeder. The MSG801 or
MSG802 can also be used. Please note that an additional CEE connector plug is re-
quired for the MSG controllers (Order number: 11006982)
Installation of the plug is only to be carried out by technically qualified personnel.
Figure 8:
End of the wire for additional plug
4
Operating instructions
The first step in adjusting the linear feeders is always to balance the masses and then to
adjust the natural frequency.
4.1
Linear tracks
The linear tracks must be unyielding so that the transport pulses generated by the unit
are fully transferred to the work pieces and no superimposed natural vibration can ad-
versely affect the transport process. This requirement has priority over mass reduction
measures. The preferred material for linear tracks is tool steel (e.g. 1.2842, 90MnCrV8).
Linear track design should adhere to the useful masses specified in chapter 2 Table 1
and/or chapter 4.2 Table 4: Recommended values for useful and counter masses with
mass difference.
The following linear track cross sectional dimension ratio is recommended:
𝑊𝑒𝑖𝑔ℎ𝑡
𝑊𝑖𝑑𝑡ℎ
=
2