o

 

lack of signal MAIN or lowering of the level of the same below the threshold 
THR reference for a time over one established.

 

o

 

detection of a level of the 19 KHz pilot signal which differs by a value greater 
than or less than ± 1 dB than the set value

 

o

 

absence of RDS signal or inconsistent data of the it

 

o

 

detection of a PI code in the RDS signal, different from that set.

 

 

o

 

Restoring the MAIN signal input or its level above the threshold THR, or one of the 
checks listed above, for the minimum time edited, the output will switch on the input 
MAIN. in this mode is the primary external command applied via contact ST IN port 
Logic I/O through which one can impose the switching input SUB regardless of the 
level of the signal MAIN.

 

o

 

STUDI

: The input signal at the output is determined by the state of the contact ST 

IN port Logic I/O, open contact = MAIN, SUB = closed contact. The control of the 
signal level, in this case, is applied to the SUB, in case of no signal or less than the 
predetermined threshold THR, the end of the observation time imposed, the output is 
switched to the MAIN regardless of the state contact ST IN

.

 

o

 

MAIN; 

manual setting and fixed input MAIN output, control the level of the signal 

shows the status of the alarm contact output port Logic I/O but does not cause 
switching. The switch from MAIN to SUB can not be activated by contact of dedicated 
Logic I/O port.

 

o

 

SUB; 

manual setting and fixed input SUB output, control the level of the signal 

shows the status of the alarm contact output port Logic I/O but does not cause 
switching. Switching from SUB MAIN can not be activated by contact of dedicated 
Logic I/O port.

 

 
STE DELAY to SUB

; pressing the jog wheel, at this entry, to access setting of the observation 

time signal MAIN, beyond which, in SUPERVISOR mode (SUPER), with allame active, the output is 
switched on the SUB. The available range is from 0 to 255 seconds 

 
STE DELAY to MAIN; 

pressing the jog wheel, at this entry, to access setting of the observation 

time of the signal level SUB, beyond which, in STUDIES mode, the output is switched on MAIN. The 
available range is from 0 to 255 seconds. 

 

STE BLANK THR; 

pressing the jog wheel, at this entry, to access setting the threshold level of 

Stereo. The available range varies from -18 to -4 dB; OFF control is disabled. 

 

MPX DELAY to SUB; 

pressing the jog wheel, at this entry, to access setting of the observation 

time signal MAIN, beyond which, in SUPERVISOR mode (SUPER), compared with alarm, the output 
is switched on the SUB. The available range is from 0 to 255 seconds 

 
MPX DELAY to MAIN; 

pressing the jog wheel, at this entry, to access setting of the observation 

time of the signal level SUB, beyond which, in STUDIES mode, the output is switched on MAIN. The 
available range is from 0 to 255 seconds. 

 

MPX BLANK THR;

 pressing the jog dial, at this entry, to access setting the threshold level of the 

stereo signal; . The available range varies from -18 to -4 dB; OFF control is disabled.

 

 

MPX PILOT LEV

;

 

pressing the jog wheel, at this entry, to access setting the threshold level of the 

pilot signal 19 KHz. The available range varies from -26 to -14 dB; OFF control is disabled. 


 

MPX RDS ALARM; 

pressing the jog wheel, at this item, you can then select the type of control 

activated the RDS signal : 

 

o

 

RDS S, 

Control of the RDS signal, data consistency in the RDS signal

 

o

 

PI CHK, 

Control of the PI code contained in the RDS signal

 

o

 

OFF, 

Disabling the control signal RDS

 

 

Содержание Dual Switch

Страница 1: ...AEV Dual Audio Switcer AEV Broadcast Srl via della Tecnica 33 40050 Argelato Bologna ITALY www aev eu mail info aev eu 1 Programable Audio Switcher...

Страница 2: ...arefully read this paragraph as it contains important instructions concerning operator safety and directions regarding the installation operation and maintenance of the equipment Failure to observe th...

Страница 3: ...lf The fuses must be replaced by qualified and authorised persons It is advisable to call your nearest dealer Call your dealer for any repairs and be certain original spare parts are used Failure to o...

Страница 4: ...nents Guarantee 2 Technical support 2 Service 2 Shipping instructions 2 Warnings 2 Contents 4 Introduction 5 General details 6 Description 6 Front panel 6 Rear panel 6 Display functions 7 Stereo secti...

Страница 5: ...d a network of bridges terrestrial radio by managing alarms and performing switching of emergency General details Dual Switch is extremely easy to program using the display and the encoder on the fron...

Страница 6: ...and output Monitor section monitor BNC connector MPX and pair RCA Dual Switch in the model Stereo allows to enable a control that provides an output OUT the same audio level of the selected input MAIN...

Страница 7: ...ing from the top downwards are displayed audio signal present at the output MAIN or SUB Management mode output SUPER STUDIO MAIN SUB Time to wait before switching from MAIN to SUB Contact status which...

Страница 8: ...e of lack of signal MAIN or lowering of the level of the same below the threshold THR reference for a time over one established Restoring the MAIN signal input or its level above the threshold THR for...

Страница 9: ...use switching Switching from SUB MAIN can not be activated by contact of dedicated Logic I O port STE DELAY to SUB pressing the jog wheel at this entry to access setting of the observation time signal...

Страница 10: ...turning the knob you select the character and with an additional press of the jog proceed the storage and the selection will move to the next character Logic I O port Pin 2 9 Opto 1 IN switching cont...

Страница 11: ...AEV Dual Audio Switcer AEV Broadcast Srl via della Tecnica 33 40050 Argelato Bologna ITALY www aev eu mail info aev eu 11 Block diagram...

Страница 12: ...onitor Stereo Output Output configuration Unbalanced Output level As Input Level Output Impedance 100 Connectors PIN RCA Monitor MPX Output Output configuration Unbalanced Output level As Input Level...

Отзывы: