LEDs
PoE
Yellow ON
PoE: Power port is connected to PD
LAN
Green flash
LAN: Data is being transmitted or received.
OFF
No connection
PWR
Yellow ON
Power is supplied
LINK
Green ON
Rx and Tx EPoC adapter is connected.
Distance/Power Chart
NOTE:
1. The numberts comply using RG6 coaxial cables.
2. The length of network cable for camera connection is 1m CAT5e cable.
3. The power delivery will vary on the quality of coaxial cable due to
resistance.
AETEK INC.
3F, No.192, Lien-Cheng Rd., Chung-Ho, New Taipei City, 235, Taiwan, R.O.C.
|
T
:
+886-2-82452822
|
W
:
www.aetektec.com
|
E
:
All specifications are subject to change without noice.
Copyright © 2020 AETEK INC. All rights reserved.
To disconnect a LAN cable, loosen the cable
gland and pull the cable against the socket
wall towards the side of the locking tab.
Outdoor LAN Port
IMPORTANT -
1. Fit a BNC plug to the coaxial cable
2. Thread the coaxial cable through the cap(A) & grip(B)
3. Split rubber(C), rubber have two sizes for meet 4.5~6.5mm or 6~8mm
coaxial cable.
4. Fit the split rubber(C) over the coaxial cable
5. Thread the coaxial cable through the body(D)
6. Fit the washer(E) to the XE62-120-TX connector
7. Plug the BNC connector on the coaxial cable into the XE62-120-TX
8. Hold XE62-120-TX and then screw the body(D) onto the XE62-120-TX
connector tighten firmly
9. Push rubber(C) in the grip(B) and screw the cap tighten firmly. The coaxial
cable is sealed when the rubber(C) & grip(B) bulges to the edge of the
cap(A). The BNC Male connector needs <38mm form coaxial cable.
Outdoor EPoC LINK Port Connector Assembly
Washer (E)
Body (D)
Rubber (C)
Grip (B)
Cap (A)
Rubber (C)
Rubber (C)
Split
Length of Coaxial Cable
300m
34.72W
500m
25.2W
800m
13.11W
1000m
10W
1200m
9.66W
1200m ~ 2400m
Data only (100Mbps)
NOTE:
The XE62-120-TX Outdoor EPoC Adapter must be
grounded using a ground wire between the
ground screw
and earth ground.
IMPORTANT:
Ground screw
* Make sure the grouning
resistance is lower than
0.5
Ω.
XE62-120-TX
Reset to default 15 seconds
Mode/Reset Button
Join Button
• Press the Join button for 1-3 seconds on both Local and Remote Extenders to Link them.
• Press the Join button on the Remote Extender for 5-8 seconds to disconnect the Link between the Extenders
• Press the Join button for 10~15 seconds to reset the Extender to default.