background image

 

Specifications 

 

 

 

 

 

 

Fuses:  
 

External fuse (in IEC power connector) 

 

2 amp slow blow (117v) 
1 amp slow blow (230v) 

Spare fuse included in IEC power connector. 

 

Tubes: 
 

V1 & V2 

12AX7LP 

V3 & V4 

12AX7WB 

V5  

6922 

(6DJ8) 

 

Power Consumption: 

 

Standby: 20 

watts 

Active:  

100  watts 

 

Dimensions: 
 

18" Width x 17 5/8" Depth x 4 3/8" Height 

 

Shipping Weight:  
 

39 lbs (17.5Kg) 

 

8

Содержание Rhea

Страница 1: ...Rhea PHONO STAGE Aesthetix Audio Corporation 5144 N Commerce Ave Suite A Moorpark Ca 93021 Phone 805 529 9901 Fax 805 529 9902 ...

Страница 2: ...ssive power supply consists of a high voltage transformer heater transformer and high voltage choke All of the magnetics are shielded by a stainless steel transformer cover that also performs double duty as the structural truss The high voltage power supply is regulated with a discrete transistor based regulator The low voltage solid state power supplies are discretely regulated Only the highest q...

Страница 3: ...ed to the unit by pressing on the left side of the power switch when viewed from the front of the unit When Rhea has power applied for the first time it will first display the installed software version on the LED display for two seconds then automatically enter the standby mode While in standby power is applied to all circuits except the vacuum tube heaters The high voltage supply is reduced to a...

Страница 4: ... own gain adjustment To adjust the gain for a different input press the gain button again to exit the gain adjust setting Select the desired input then re enter the gain setting mode The selected gains are stored in non volatile memory and will therefore not be lost even if the power is disconnected The mute button is active while in the gain adjustment mode The below chart shows the recommended g...

Страница 5: ...ge When the demagnetizing cycle is complete the demag light will extinguish and normal operation will return No buttons are active while demagnetizing Cartridges should be demagnetized weekly or anytime a muddiness or lack of clarity becomes apparent To demagnetize a different input simply select the desired input and then activate the demagnetizer When not in use the demagnetizer is fully deactiv...

Страница 6: ...ow two numbers in the range 00 15 one on the left display and one on the right display The left number indicates the light level that the sensor is reporting 0 is darkest and 15 is brightest The rightmost number indicates the display brightness setting for that light level 0 is darkest and 15 is brightest LED 2 will be lit which indicates that pressing the up or down buttons will adjust the displa...

Страница 7: ...h changes in ambient light level in the room Restoration of the factory default settings To restore the factory settings for all display settings first press and hold the display button then concurrently press 3 button This can only be done from the front panel LEDs 1 5 will light indicating that the unit has restored the factory settings Maintenance Do not under any condition remove the top cover...

Страница 8: ...mp slow blow 117v 1 amp slow blow 230v Spare fuse included in IEC power connector Tubes V1 V2 12AX7LP V3 V4 12AX7WB V5 6922 6DJ8 Power Consumption Standby 20 watts Active 100 watts Dimensions 18 Width x 17 5 8 Depth x 4 3 8 Height Shipping Weight 39 lbs 17 5Kg 8 ...

Страница 9: ...f any product without obligation to purchasers of previously manufactured products and to change the prices or specifications of any product without notice or obligation to any person 3 REMEDY In the event the above product fails to meet the warranty and the above conditions have been met the purchaser s sole remedy under the limited warranty shall be to return the product to Aesthetix where the d...

Отзывы: