IR (Infrared) 

 

The factory default is Metis. 
 
From the Main menu, to set whether the Metis responds to a default Metis or Calypso remote, press the Left 
knob and turn it until the display reads SETUP GEN*.  Press the Right knob to enter this sub menu.  Turn the 
Left knob until IR: XX is displayed, and then turn the right knob to METIS or CALYPSO.  Pressing the Left knob 
will exit this sub menu. 

 

     

     

     

     

 

 

 

Set Up Display (Advanced Display Functionality) 

 

Note:  If edited via the front panel, the user’s hand or body could shadow the path of the ambient room light level 

that the Metis light sensor reads.  Therefore it is recommended to view/edit this feature via the hand held 
remote. 

 
 

The Metis is able to sense the ambient light level in the room and adjust its LED brightness accordingly.  While 
the factory settings will work for most situations, there may be times when adjustment to the settings is useful. 

 

Should it be desired to edit these settings, from the main menu, press the Left knob and turn it until the display 
reads SETUP GEN*.  Press the Right knob to enter this sub menu.  Turn the Left knob until SETUP DISP is 
shown, and then press the Right knob to enter this sub menu. 

 

     

     

     

     

 

 

The display will read RM:YY  LED:ZZ.  YY = the room brightness and ZZ = the LED brightness for that room light 
level.  Each has a range between 0 and 15, where 0 is the darkest and 15 the brightest. 

 

To make adjustments, turn the Left knob to the desired ambient room light level setting and then turn the Right 
knob to adjust the LED brightness for that room light level.    Pressing the Left knob once will revert to the 
Display Setup menu, twice to get to the General Setup menu, and once more to get to the Main menu. 

 

     

 

 

Note:

 Setting all brightness levels to the same value, for all light levels, will result in no change of LED brightness 

with changes in ambient light level in the room. 

 
 

Restoring the Factory Settings 

 

From the Main menu, to restore the Metis factory settings, press the Left knob and turn it until the display reads 
SETUP GEN*.  Press the Right knob to select this sub menu.  Turn the Left knob until RESTORE: is displayed.  
Turn the right knob to YES (or NO to abort).  At YES, press the Right knob.  Pressing the Left knob will exit this 
sub menu. 

     

     

     

    

     

 

 

Содержание METIS Linestage

Страница 1: ...Aesthetix Audio Corporation 5220 Gabbert Rd Suite A Moorpark CA 93021 Phone 805 529 9901 M E T I S Linestage Owner s Manual ...

Страница 2: ...ateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE CAUTION TO PREVENT ELECTRIC SHOCK DO NOT USE THE AC POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADE...

Страница 3: ...transformers The Metis has an internal floating power supply which is isolated from the chassis when placed on a stand The only contact with the rest of the unit is the transformer wires connected the power supply circuit board PLACEMENT The Metis should be located away from possible sources of hum such as power cords power transformers and the like It should not be located near any other heat sou...

Страница 4: ...Metis to protect it from overheating as well as the continued functionality of any equipment near and around it WARNING United States law prohibits disposition of these commodities to Libya Laos North Korea Cambodia Syria or Cuba unless otherwise authorized by the United States AFTER MARKET and THIRD PARTY MODIFICATIONS Please note that any aftermarket and or third party modifications will void th...

Страница 5: ... EACH SIDE OF THE UNIT ALSO ALLOW AT LEAST 3 INCHES OF VENTILATION SPACE ABOVE THE UNIT IMPROPER VENTILATION OF THE UNIT MAY CAUSE OVERHEATING WHICH MAY DAMAGE THE UNIT AND CAUSE A FIRE PLACE THE UNIT ON A SOLID SURFACE ONLY I E NOT ON CARPET ETC DO NOT PLACE THE METIS NEAR HEAT SOURCES SUCH AS DIRECT SUNLIGHT STOVES HEAT REGISTERS RADIATORS OR OTHER HEAT PRODUCING EQUIPMENT IF REPLACEMENT OF THE ...

Страница 6: ...andby 10 Introduction to the User Interface 11 OPERATION 12 Main Menu 12 Tape In 12 Phase 12 Balance 12 Display 12 Setup 12 Setup General 13 Tape Out 14 Start Level 14 Max Level 14 Trigger 14 IR Infrared 15 Set Up Display Advanced Display Functionality 15 Restoring the Factory Settings 15 Setup Input 16 Input On Off 16 Input Level 16 Home Theater Bypass 17 Input Name 17 RS232 17 Appendix A Trouble...

Страница 7: ...n Menu Press to enter sub menus and turn to change sub menus as outlined in this manual 2 STANDBY button After the rear panel Main Power switch is turned on press the illuminated front panel Standby button in the center of the logo to exit the standby mode Pressing this button again will put the Metis into Standby and illuminate the button LEDs 3 LED Display All menus sub menus are displayed in Ap...

Страница 8: ...ono input jacks and ground connector Optional 9 Right channel balanced and single ended Main Output jacks 10 IR extender input jack Connect external IR receiver to this input 11 DB9 RS232 connector Used for connecting a system control device to the Metis to control and monitor its functions 12 Remote Trigger jack When set to do so as the Standby button is pressed to take the Metis out of standby t...

Страница 9: ... when connecting disconnecting cables Optional Connection Figure 3 Rear Panel Layout showing connections AC Power The Metis may be plugged directly into an un switched wall outlet Although proprietary RFI radio frequency interference filtering is built into the Metis in some situations an AC power line filter may provide additional sonic benefits ...

Страница 10: ...er amplifier inputs Ensure that the power amplifiers are off or muted prior to making connections to and tuning on the Metis rear panel power switch Turn on the rear panel power switch Note The hand held remote is shipped in Transport mode off It must first be set to Active Please refer to the remote owner s manual See the Metis Remote Owner s Manual If it s not already install one battery in the ...

Страница 11: ... 4 levels 1 Main menu This displays information about the currently selected input the master volume if the Metis is Muted or if the currently selected input is Bypassed 2 Main menu sub features Quick access is given to turning the Tape Input jack On or Off inverting the Phase shifting the L R Balance viewing extinguishing the Display LEDs and editing in the General and Input Setup menus 3 Setup G...

Страница 12: ...nput X is being routed to the Tape Output The Metis can be muted un muted by pressing the Right knob Phase Continuing to turn the Left knob clockwise allows the user to set the Phase to 0 or 180 degrees by turning the Right knob Balance Turn the Left knob clockwise again will display the Balance feature Turning the Right knob clockwise or counter clockwise will shift the balance to the right or le...

Страница 13: ...he Metis or Calypso remote control o Setting up the front panel display brightness options o Restoration of factory presets At any time that a sub menu is displayed unless pressing the Right knob is required to enter a sub menu pressing it will Mute Un mute the Metis There are up to 3 levels of sub menus When at the first level pressing the Left knob once will exit and return to the Main menu When...

Страница 14: ...hen turn the right knob to the desired level Press the Left knob once to revert to the Setup menu or twice to return to the Main menu The change s will take affect after the Metis has been put into Standby Max Level The factory default is 88 and the programmable range is 50 88 From the Main menu to set the maximum level that the Metis will go to press the Left knob and turn it until the display re...

Страница 15: ...lay reads SETUP GEN Press the Right knob to enter this sub menu Turn the Left knob until SETUP DISP is shown and then press the Right knob to enter this sub menu The display will read RM YY LED ZZ YY the room brightness and ZZ the LED brightness for that room light level Each has a range between 0 and 15 where 0 is the darkest and 15 the brightest To make adjustments turn the Left knob to the desi...

Страница 16: ...to be edited Press the Right knob to enter this sub menu and then turn the right knob to ON or OFF Pressing the Left knob will exit this sub menu If SETUP GEN is displayed turn the Right knob to display INPx Input Level The factory default is 0 Sources may have different output levels To streamline this the Metis allows the user to adjust any Input level to match that of other sources The range is...

Страница 17: ...ntil the display reads SETUP INx Turn the Right knob to select Inx where x the input number to rename Press the Right knob to enter this sub menu then Turn the Left knob to display INPUTxNAME Press the Right knob enter the Naming sub menu Turn the Left knob to the desired character to edit This character position will be underlined Turn the Right knob to select the desired character To edit anothe...

Страница 18: ...ate voltage Power Supply fuse s is are open Replace with same type and rating ONLY Rear panel fuse is open Replace with same type and rating ONLY Circuit breaker is open AC outlet Check the AC outlet circuit breaker and reset if necessary or contact your dealer No audio output Incorrect source is selected Look in the display to verify that the correct source is shown If it is not press the Input b...

Страница 19: ...19 Appendix B Menu Map ...

Страница 20: ...RS232 Pinout Figure 4 Metis RS232 Jack Pinout These are the connector drawings only The RS232 cable must be a regular RS232 or mouse extender cable wired pin for pin The RS232 Protocol data is available upon request ...

Страница 21: ...nced 300 ohms Polarity Balanced Pin 1 Ground Pin 2 Non inverting Positive Pin 3 Inverting Negative Tubes V401 E83CCS or 12AX7 V402 6922 6DJ8 RS232 1 DB9 connector Trigger Input Output 1 8 Jack operates on either 5 12 VDC or Pulse 100mS or 5 12V DC Dimensions 17 13 16 W x 18 1 2 D x 6 1 16 H 45 2 x 15 4 x 47cm Weight 42 Lbs Stand alone 19 Kg 51 Lbs Boxed with accessories 23 1 Kg Maximum Operating I...

Страница 22: ...and to change the prices or specifications of any product without notice or obligation to any person 3 REMEDY In the event the above product fails to meet the warranty and the above conditions have been met the purchaser s sole remedy under the limited warranty shall be to return the product to Aesthetix where the defect will be rectified without charge for parts or labor Aesthetix reserves the ri...