EG IN (EGRESS INPUT)
Connect a push button between this terminal and (-)GND. When Egress button is pressed, output 1 
will be activated for the programmed delay. Egress button is usually located inside a building and 
used as a push to exit.

K or A. (KEYPAD ACTIVE OUTPUT)
An NPN transistor open collector output. It switches to (-) ground for 10 seconds on each key 
touching. This can be used to turn on lights, CCTV camera, or buzzer to notify a guard. The rating 
of this output is: Ic max: 100mA sink, Vc max: 24VDC

DU OUT (DURESS OUTPUT)
An NPN transistor open collector output. It switches to (-) ground after the Duress Code is entered. 
Use it to trigger an alarm zone, or turn on a buzzer to notify a guard. Ic max: 100mA sink. Vc max: 
24VDC

Additional keypad information 

– 

Note: These features are not commonly used.

Keypad Programming (only ABK models)

Memory locations
000-999 for relay 1
001-100 for relay 2
001-100 for relay 3

1

0

2

0

Programming SUPER user code

0

10

= relay 1 codes 

(1000 available)

20

= relay 2 codes

(100 available)

30

= relay 3 codes

(100 available)

Programming Relay output times & modes

?

?

0

1

-

0 = start / stop toggle mode (latching)
1-99999 = seconds momentary operation

Note: Programming can only begin 60 seconds after power on.

Enter new programmers code

Location

0

1

?

?

?

?

4-8 digit code

Validate

#

Super user code is an optional feature which allows the same code to operate outputs 1, 2 or 3.

Enter new user code or Delete user codes

?

?

?

?

#

0

2= add code
5= delete code

Pin code 4-8 digits

Validate

Example: Add user 31 to have access code 5555 operating relay 2

….

2

0

2

0

3

5

5

5

5

#

1

Group 2

Add code

Location 31

Pin code 5555

Validate

Delete a code

?

?

5

?

?

?

#

10

=relay1

20

=relay2

30

=relay3

Delete code

ID location to be deleted

Validate

Delete all codes in a group

?

?

0

9

9

9

#

10

=relay1 group

20

=relay2 group

30

=relay3 group

Super delete code

Validate

9

9

9

9

9

or

#

51

=relay1

52

=relay2

53

=relay3

Validate

Location

0

2

?

?

?

?

4-8 digit code

Validate

#

Using super user code

?

?

?

?

#

1

Activate output 1

?

?

?

?

#

2

Activate output 2

?

?

?

?

#

3

Activate output 3

Restoring defaults

While in programming mode, enter the following to delete all codes and settings apart from the 
Master code.. (this can take up to 2.5 minutes)...

9

9

9

9

#

When the master code is forgotten….

1) Wire a push button (or replicate with wire link) across the EG IN terminal and (-)GND. 
2) Switch off power for 1 minute.
3) Switch ON power.
4) during the first 60 seconds, press the EG button once to enable the function.
5) Enter the following code..

8

0

0

8

*

*

The keypad should now be in programming mode, ready to accept new data.

DOOR SENSE
N/C connected to (-)GND, to be connected to a normally closed door contact. It can be used to 
generate a door open alarm or door forced open alarm.

O/P 1 Inhibit
Normally open. When closed, this disables all codes for relay group 1 except super user and duress 
codes.

Interlock Output
NPN transistor output, open collector, max power 24v dc, 100mA sink. Used to operate a door in 
conjunction with another keypad, or prevent two doors being opened at the same time.

Tamper N/C
Normally closed tamper switch. This can be used in conjunction with a tamper switch on a box or 
enclosure to prevent tampering. This can be connected to an alarm system.

LED indicators

ON when incorrect codes entered and outputs are locked out.

1

2

3

4

5

6

7

8

9

*

0

#

SLOW FLASHING - in normal standby mode.

ON in programming mode.

ON when relay 3 activated.

GREEN when output 1 activated. 
RED when output 2 activated.

FAST FLASHING 

– Wrong code entered / error.

0

0

0

0

*

*

Quick start guide

1) Enter programming mode (amber LED should be ON)

1

0

2

0

0

?

?

?

?

#

0

2) Enter a new user code...

*

*

3) Exit programming mode

(amber LED should be OFF)

Advanced Programming Features

4) Enter the new user code to check the relay clicks.

For any settings shown below, first enter programming mode as 
shown above...

Note: Exit programming mode before using either user codes or super user codes.