14
refer to below table:
Heat pump
Cable size
EFI 14
3x2.5mm
2
/AWG 14
EFI 17
3x2.5mm
2
/AWG 14
EFI 21
3x4.0mm
2
/AWG 12
The above wiring information is to be used as a guide only. Electrical connection must be made in accordance
with
AS/NZS 3000:2018 wiring rules.
Use the cable glands and grommets provided inside the heat pump to route cables.
If the length of your cable is more than 10 meters, we advise you to seek advice from a professional.
A voltage variation of ± 10% during operation is acceptable.
The power supply lines must be securely fastened.
The cable must be suitable for outdoor use.