P a g e
|
6
Output Connections Example
12v dc
N/C
COM
N/O
GSM
modem
close
N/C
COM
N/O
Out 1
Out 2
eg
S
ta
rt
C
o
m
m
o
n
Gate motor controller
12v dc
Separate
PSU
+
+
-
-
Other exit
device, e.g.
keypad
Magnetic
Lock
Other exit
device, e.g.
keypad
This example shows relay 1 connected to a gate motor controller for vehicle gates, and output 2
connected to a magnetic lock for a door or pedestrian gate.
Powering Up
Perform a final check of wiring and ensure the antenna is connected before switching on the
power. Once the power is switched on, the power LED should illuminate.
Power LED
CPU LED
Signal LED
Searching
1 bar signal
2 bars signal
3 bars signal
4 bars signal
System booted
Booting
GSM
modem
TIPS:
My GSM LED is still searching…
-Check the SIM card is registered and can make a
call in a phone.
-Check the SIM card is seated correctly. Power off,
clean the contacts on the SIM and the GSM unit,
and reinsert the SIM.
-Check power cable distance and thickness.
-Increase antenna height.
-Change network.
-Move antenna away from metal objects or
overhanging shrubs.
-Fit a high gain antenna.