Aerus Pure & Clean Plus A1041A Скачать руководство пользователя страница 2

2

PRODUCT OVERVIEW

Congratulations on your purchase! Your new Aerus

®

 Pure & Clean+ is designed to provide years of trouble-free, low maintenance operation. 

Be sure to read and follow all service procedures outlined in this owner’s manual, and use only genuine Aerus replacement parts.

CONTENTS

Product Overview.     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .   2

Specifications.     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .   2

Important Safety Instructions  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   3

For Canadian customers only  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  4

Inspection & Installation  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   5

Unit Features   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   5

Operation  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  6

Settings & Adjustments    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  7

LED Display  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  8

Maintenance Reminders  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   8

General Maintenance.     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .   9

Removing the Filter Assembly .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10

Uninstalling the Optional HEPA Filter Sheet .   .   .   .   .   .   .   .   .   .   .   .  11

Removing the Purifier Plate & ActivePure

®

 Cell .  .  .  .  .  .  .  .  .  . 12

Installing the Purifier Plate & ActivePure

®

 Cell .     .     .     .     .     .     .     .     .     .     . 13

Troubleshooting    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 14

Replacement Parts & Service   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 15

Warranty Information.     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     .     . 16

FCC Declaration & Responsible Party .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 17

GENERAL INFORMATION

 

SPECIFICATIONS

Aerus Pure & Clean+

• Model Number: A1041A
• Sales Number: 00747

Technology

:

• ActivePure

®

 (1 Cell)

• Purification Plate • HEPA Filter Screen
• Activated Carbon Filter
• Carbon Brushes

Electrical:

• Input Voltage: 100 ~ 240 VAC; 50/60 Hz 
• External power supply: DC 24 Volts; 1.5 Amps Max
• Power Consumption: 43 Watts Max 
• Conforms to UL STD 867

Mechanical:

• Nominal Airflow Rate: 40-60 CFM Adjustable Speed Fan

Sound Level:

• 45 dB(A) on low; 55 dB(A) on high

Weight & Dimensions:

• 7.6 lbs (3.45 kg)
• 11.75” H x 9.5” W x 10” D  

  (29.8 cm x 24.1 cm x 25.4 cm)

Operating Temperature:

• 34°F – 100°F (1.6°C   – 38°C)

Purification Plate Output (High Mode):

• > 2.0 ppm ozone

Recommended Maximum Coverage  

in a Contiguous Space

1

:

• Up to 2,000 sq. ft. (185m

2

) depending on occupant  

   density and other factors

1

. High density commercial  

   not to exceed  500 sq. ft. (46m

2

).

Warranty:

• Limited three (3) year warranty

1. Assumes 8 foot ceilings. Solutions should be customized based upon a variety of factors including 
HVAC system capabilities and settings, air flows taking into account walls, air pressure, and doors, 
ambient air temperatures and humidities, variable density, known VOC concentrations, and other 
layers of protection.

Aerus, LLC reserves the right to change or modify any 
specification without notice.

If you have any questions regarding the use of this, or any Aerus product, contact your Independent 

Distributor/Contractor or Aerus Customer Service at 800.572.0502 (U.S.) or 800.668.0763 (CANADA).

Record information regarding your new Aerus Pure & Clean+ here. 
Retain for future reference.
Model No.

Serial No.

Date of Purchase

Independent Distributor/Contractor:

Name

Phone No.

Address

FILL IN AND SAVE

STORAGE AND DISPOSAL 

Do not dispose of this product as household waste. Electrical waste

 

and 

electronic products should be appropriately recycled as required by 
practices established by your local authority.

95760-CHN-1

EPA Est.

Содержание Pure & Clean Plus A1041A

Страница 1: ...READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION PORTABLE AIR PURIFICATION SYSTEM ...

Страница 2: ... dB A on low 55 dB A on high Weight Dimensions 7 6 lbs 3 45 kg 11 75 H x 9 5 W x 10 D 29 8 cm x 24 1 cm x 25 4 cm Operating Temperature 34 F 100 F 1 6 C 38 C Purification Plate Output High Mode 2 0 ppm ozone Recommended Maximum Coverage in a Contiguous Space1 Up to 2 000 sq ft 185m2 depending on occupant density and other factors1 High density commercial not to exceed 500 sq ft 46m2 Warranty Limit...

Страница 3: ...cord Always unplug the unit before moving or cleaning or whenever the unit is not in use DO NOT use outdoors or on wet surfaces DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit doing so will void your warranty Connect to properly grounded outlets only To reduce the risk of electrical shock do not change the plug in any way DO NOT use adapters CAUTION Allow you...

Страница 4: ...is device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using handling storing and disposing of the device and procedures to mitigate any associated risks The use of this device is a supplement to and not a substitute for standard infection control practices users ...

Страница 5: ...om Mode w Adjustable Digital Timer UNIT FEATURES 1 Remove protective packaging 2 Remove unit from shipping carton 3 Remove all protective materials 4 Check for shipping damage and loose or broken parts 5 Read Owner s Manual thoroughly prior to installation 6 Determine placement location for the unit See Operation on page 5 7 Insert the Power Supply Plug into the power receptacle on the rear of the...

Страница 6: ...T ROOM and the remaining time To interrupt the DEPART ROOM press the A PURE A PURE button A PURE MODE The unit s display shows the fan speed low to high and A PURE to indicate that the ActivePure Cell and ionization are both functioning normally A PURE MODE A PURE lights up adjustable purifier coverage 500 1000 2000 3000 in square feet and fan speed 1 2 3 4 5 ION MODE Ion lights up indicates only ...

Страница 7: ... graph and square footage The unit will switch to A PURE Mode if the Purifier DOWN button is pressed A PURE A PURE Toggles the unit between A PURE Mode ActivePure and Ionization and A PURE Mode 1 ActivePure Cell Ionization and Purification Plate REMINDER RESET Clears the maintenance reminders after performing routine maintenance DEPART ROOM Turns on and adjusts the timer for the Depart Room Mode E...

Страница 8: ...ith a new Purifier Plate available from your local VolIara Independent Business Owner PERFORM CLEANING The perform cleaning CLEAN indicator will come on approximately every 40 days Clean the Filter Assembly See Page 8 Vacuum the ActivePure Cell Clean the Purifier Plate see page 8 Vacuum Top and Rear Grill openings NOTE Be sure to press the Reminder Reset icon to clear the reminder following regula...

Страница 9: ...763 CANADA Resetting the Reminders The reminders you need to reset are the PERFORM CLEANING and REPLACE ACTIVEPURE CELL indicators after performing maintenance press the Reset icon and the screen will stop flashing to let you know the reminder has been cleared please see above instructions for each indicator GENERAL MAINTENANCE Unplug the unit before performing any maintenance procedures WARNING P...

Страница 10: ...brush This will cut the grease without leaving a residue For all applications Clean with a mixture of one part water and one part ammonia to remove contaminants Place the plate into a shallow dish and pour enough of the water ammonia solution into the dish to just cover plate Allow the plate to soak for no more than 10 minutes Remove plate and scrub with a soft bristle brush Rinse thoroughly Let a...

Страница 11: ...educe VOCs and other contaminants NOTE Removing the Optional HEPA Filter Sheet will increase the airflow of the unit UNINSTALLING THE OPTIONAL HEPA FILTER SHEET Unplug the unit before performing any maintenance procedures 1 Remove the Filter Assembly See Page 8 2 Remove the Optional HEPA Filter Sheet on top of the Prefilter 3 Replace the Filter Assembly inserting the bottom of the Filter Assembly ...

Страница 12: ...out the Filter Assembly and Back Cover properly installed NOTE Use genuine Aerus replacement parts only Parts from anyone other than Aerus may damage your unit and void your warranty 3 Pull the connector straight out to unplug 2 Unlock the ActivePure Cell connector by pressing on the connector s locking tabs 1 To remove the Purification Plate grasp edge of plate in the center and gently pull out 4...

Страница 13: ...r of the plate cage and that the angle brackets and studs are correctly aligned 2 Insert the two thumbscrews and tighten Insert the ActivePure Cell connector into the plug on the plate cage 3 Press the connector firmly until the two tabs lock into place 4 Gently insert the Purifier Plate between the guides inside the cage until it stops 7 Replace the Back Cover by inserting the bottom in and snapp...

Страница 14: ... this question also 4 The UV Lamp is not functioning I m getting a Replace ActivePure Cell Message Check ActivePure Cell for proper installation Replace the ActivePure Cell 5 What are the most typical application problems Symptom A belief that the proper equipment is placed in the environment and the equipment appears unsuccessful Problem Lack of air movement improper placement of the unit Symptom...

Страница 15: ...n Plate not available in California 50109 Filter Assembly 50107 Power Supply with U S Euro Plug 50108 To order replacement parts contact your Independent Distributor Contractor or Aerus Customer Service at 800 572 0502 U S or 800 668 0763 CANADA REPLACEMENT PARTS SERVICE ...

Страница 16: ...warranty coverage prior to purchasing a product contact Aerus Customer Service at 800 572 0502 U S or 800 688 0763 CANADA with the serial number located on the back of the unit EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN AND TO THE EXTENT CONSISTENT WITH APPLICABLE LAWS WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ...

Страница 17: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipment o...

Страница 18: ... this product please contact Customer Service 800 572 0502 U S 800 668 0763 CANADA www aerusonline com Aerus LLC 1300 Valley Drive Bristol VA 24201 800 572 0502 Aerus Canada Inc 3480 Laird Road Suite 2 5 Mississauga ON L5L 5Y4 800 668 0763 Aerus LLC All Rights Reserved ...

Отзывы: