Aertesi SOFFIO 101HP Скачать руководство пользователя страница 3

AERTESI srl                                            SOFFIO                 INSTALLATION USE AND MANTEINANCE MANUAL

 

 

Page 3     AER.MIU.GB.SOFFIO.000.02.15 

 

1-INTRODUCTION 

Series  units  SOFFIO  are  designed  for  the  function  of  heating,  cooling,  dehumidification  and  filtration  of 

residential and commercial application (offices, public buildings, or so) with the counterceiling. 

Following applications are not permitted: 

1. Working outdoors 

2. Operations in high humid environments or explosive or dusty 

3. Operations in corrosive environments, in particular for the aluminum fins of the coil 

The use of the unit is not suggested for persons (including children) with reduced physical, mental or sensory 

abilities,  or  people  who  have  not  received  adequate  information,  without  the  supervision  of  a  person 

responsible for their safety. 

The  installation  and  maintenance  of  the  unit  is  reserved  to  qualified  persons  (each  to  his  task)  and  have 

received  necessary  instructions.  These  operations  must  be  done  in  accordance  with  safety  regulations  in 

force.  These  standards  may  be,  for  example,  work  safety  (use  of  protections  for  the  eyes  and  hands,  ...), 

plant and electrical installations, pressure vessels, refrigeration equipment, lifting equipment. 

The manufacturer  /  seller  is  not  responsible  for  damage  to persons  or  property  resulting  from  the failure  of 

requirements  in  this  manual  of  regular  maintenance  or  use  of  non-original  spare  parts  or  change  in  the 

product status with respect to upon receipt. Also in these cases will void the warranty on the product. 

This manual must be kept with the unit. 

2-RECEPTION 

Unit is delivered packed in carton packaging and plastic film. Do not add weight on the packaging and not to 

stack more boxes than such as are preview at the time of delivery. Check in the product label is present the 

same  code  of  the  order  and  there  are  no  damage  to  the  packaging  or  the  product.  In  case  of  non-

compliance, immediately contact the manufacturer or the seller and not proceed with the installation. Do not 

dispose of packaging in the environment; dispose of it in compliance with the rules on waste disposal. 

3-POSITIONING 

The unit must be positioned in an appropriate  location, to minimize  pressure drop on the channels and the 

noise  emitted  into the  environment.  There  should  be  no  installed  with  furniture  (such  as  shelves,  cabinets, 

bookcases)  under  the  machine,  which  might  prevent  the  accessibility  and  the  correct  intake.  The  distance 

between the ceiling and the false ceiling must be at least 15mm greater than the height of the machine. 

The machine must not be exposed to direct sunlight or heat sources. 

It’s  necessary  to  provide  an  inspection  hatch  in  the  ceiling  under  the  machine,  in  order  to  perform 

maintenance. 

Содержание SOFFIO 101HP

Страница 1: ...AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Page 1 AER MIU GB SOFFIO 000 02 15 INSTALLATION USE AND MAINTENANCE MANUAL SOFFIO SOFFIO HP Ducted units...

Страница 2: ...000 02 15 INDEX 1 INTRODUCTION 3 2 RECEPTION 3 3 POSITIONING 3 4 INSTALLATION 4 5 AERAULIC CONNECTIONS 6 6 IDRAULIC CONNECTIONS 7 7 ELECTRICAL CONNECTIONS 7 8 MANTENANCE 9 8 1 Filter 9 8 2 Fan motor...

Страница 3: ...roperty resulting from the failure of requirements in this manual of regular maintenance or use of non original spare parts or change in the product status with respect to upon receipt Also in these c...

Страница 4: ...lm and all guards before installation The machine must always be handled by two people and or with suitable lifting means for the larger sizes Apply four or six threaded rods M8 not provided to the ce...

Страница 5: ...with fixing nut washer and nut M8 not supplied We recommend using a suitable system for not transferring to the structure some possible vibration vibration damping rubber or other material Antivibrat...

Страница 6: ...the current standards and with attention for the safety of people 5 AERAULIC CONNECTIONS Connect the channels using the appropriate outlet flange It is advisable to interpose a flexible connection be...

Страница 7: ...ecting pipe don t twist coils and valves it is recommended to use two wrench Valves can be supplied in the kit to be assembled by the installer or by delivered by the installer When the installation i...

Страница 8: ...frequency of the power supply is 230V 50Hz Before attempting any operation on the unit check the main power supply is disconnected and can not be turned on unintentionally In the basic version the ele...

Страница 9: ...accidentally inserted Make sure the engine is stopped before opening the panel of the box The motor the coil and the drainage pump do not require routine maintenance The filter instead requires period...

Страница 10: ...n of the filter from below For vertical sizes is only possible extraction from the front In these cases you must remove the brackets that block the filter Removing the filter with engines with a high...

Страница 11: ...move the bottom panel Then unscrew the M6 screws that secure the motor plate to the machine frame 2 screws for size 21 4 screws for size 31 38 5 screws for size 41 81 Fixing screw size 21 Fixing screw...

Страница 12: ...operations in reverse order 8 3 Fan HP motor high pressure In versions High Prevalence after removing the bottom panel and disconnect the motor cables as described in the previous paragraph you must r...

Страница 13: ...lower speed min or med In summer or winter hot air comes out cold air Water too hot cold Check if temperature of inlet water is less than 10 C in summer or more 40 C in winter Water flow low Check if...

Страница 14: ...___________ ________________________________________________ ________________________________________________ ________________________________________________ _________________________________________...

Страница 15: ...Aertesi srl Unipersonale viale della tecnica 6a 35026 Conselve PD ITALY t 39 049 9501109 f 39 049 9500823 www aertesi com info aertesi com AER MIU GB SOFFIO 000 02 15...

Отзывы: