background image

AERTESI srl                                            SOFFIO                 INSTALLATION USE AND MANTEINANCE MANUAL

 

 

Page 1     AER.MIU.GB.SOFFIO.000.02.15 

 

 

 

INSTALLATION, 

USE AND MAINTENANCE MANUAL 

 

 

 

SOFFIO 

– SOFFIO HP 

Ducted units

 

 

 

 

Содержание SOFFIO 101HP

Страница 1: ...AERTESI srl SOFFIO INSTALLATION USE AND MANTEINANCE MANUAL Page 1 AER MIU GB SOFFIO 000 02 15 INSTALLATION USE AND MAINTENANCE MANUAL SOFFIO SOFFIO HP Ducted units...

Страница 2: ...000 02 15 INDEX 1 INTRODUCTION 3 2 RECEPTION 3 3 POSITIONING 3 4 INSTALLATION 4 5 AERAULIC CONNECTIONS 6 6 IDRAULIC CONNECTIONS 7 7 ELECTRICAL CONNECTIONS 7 8 MANTENANCE 9 8 1 Filter 9 8 2 Fan motor...

Страница 3: ...roperty resulting from the failure of requirements in this manual of regular maintenance or use of non original spare parts or change in the product status with respect to upon receipt Also in these c...

Страница 4: ...lm and all guards before installation The machine must always be handled by two people and or with suitable lifting means for the larger sizes Apply four or six threaded rods M8 not provided to the ce...

Страница 5: ...with fixing nut washer and nut M8 not supplied We recommend using a suitable system for not transferring to the structure some possible vibration vibration damping rubber or other material Antivibrat...

Страница 6: ...the current standards and with attention for the safety of people 5 AERAULIC CONNECTIONS Connect the channels using the appropriate outlet flange It is advisable to interpose a flexible connection be...

Страница 7: ...ecting pipe don t twist coils and valves it is recommended to use two wrench Valves can be supplied in the kit to be assembled by the installer or by delivered by the installer When the installation i...

Страница 8: ...frequency of the power supply is 230V 50Hz Before attempting any operation on the unit check the main power supply is disconnected and can not be turned on unintentionally In the basic version the ele...

Страница 9: ...accidentally inserted Make sure the engine is stopped before opening the panel of the box The motor the coil and the drainage pump do not require routine maintenance The filter instead requires period...

Страница 10: ...n of the filter from below For vertical sizes is only possible extraction from the front In these cases you must remove the brackets that block the filter Removing the filter with engines with a high...

Страница 11: ...move the bottom panel Then unscrew the M6 screws that secure the motor plate to the machine frame 2 screws for size 21 4 screws for size 31 38 5 screws for size 41 81 Fixing screw size 21 Fixing screw...

Страница 12: ...operations in reverse order 8 3 Fan HP motor high pressure In versions High Prevalence after removing the bottom panel and disconnect the motor cables as described in the previous paragraph you must r...

Страница 13: ...lower speed min or med In summer or winter hot air comes out cold air Water too hot cold Check if temperature of inlet water is less than 10 C in summer or more 40 C in winter Water flow low Check if...

Страница 14: ...___________ ________________________________________________ ________________________________________________ ________________________________________________ _________________________________________...

Страница 15: ...Aertesi srl Unipersonale viale della tecnica 6a 35026 Conselve PD ITALY t 39 049 9501109 f 39 049 9500823 www aertesi com info aertesi com AER MIU GB SOFFIO 000 02 15...

Отзывы: