Installation and Configuration
BL
Disconnect the motor from the controller and connect the motor in the test configuration shown in Figure 2-
12. This method will require a two-channel oscilloscope, a 5V power supply, and six resistors (10,000 ohm,
1/4 watt). All measurements should be made with the probe common of each channel of the oscilloscope
connected to a neutral reference test point (TP4, shown in Figure 2-12).
To determine the relative phasing/order of the three motor lead signals in relation to each other, connect chan-
nel 1 of the oscilloscope to TP1. Connect channel 2 to TP2 and move the motor in the positive direction
(CW) by hand. Note the peak of the sine wave signal of channel 1 in comparison to the peak of the sine wave
signal of channel 2. Next, disconnect channel 2 from TP2 and reconnect it to TP3 and again move the motor
in the positive direction. Note the peak of the sine wave signal of channel 3 in comparison to the peak of the
sine wave signal of channel 1.
Aerotech phasing configuration expects ØC to be the lead signal (in time), ØB to follow it, and ØA to follow
ØB. This means that whichever signal has its sine wave peak farthest to the left should be designated as the
ØC signal.
Figure 2-12:
Motor Phasing Oscilloscope Example
www.aerotech.com
Chapter 2
25
Содержание BL 10-40
Страница 4: ...BL Table of Contents iv www aerotech com...
Страница 6: ...BL List Of Figures vi www aerotech com...
Страница 8: ...BL List of Tables viii www aerotech com...
Страница 10: ...x www aerotech com BL Declaration of Conformity...
Страница 16: ...BL Introduction 6 Chapter 1 www aerotech com...
Страница 38: ...BL Installation and Configuration 28 Chapter 2 www aerotech com...
Страница 54: ...BL Wiring Configurations 44 Chapter 3 www aerotech com...
Страница 68: ......