2.2. Power Connections
The BL has two AC input connectors; one for control power, and a second for motor power. For a complete
list of electrical specifications, refer to Section 1.1.
2.2.1. Control Supply Connections
The control power supply input allows the BL to maintain communications if the motor power is removed,
such as in an Emergency Stop condition. The control power supply requires a minimum of 85 VAC input to
operate properly. The AC1 input is internally fused (at 3 A). AC2 may require an external fuse or circuit
breaker (3 A, time delay).The figure below shows the required connections to the control power input.
N OT E :
This product requires two power supply connections. The Motor Supply and Control Supply must
both be connected for proper operation.
Figure 2-1:
Control Supply Connections
Table 2-1:
Control Supply AC
Input Wiring
Pin
Description
Recommended Wire Size
AC1 85-240 VAC Control Power Input
2.00 mm
2
(#14 AWG)
AC2 85-240 VAC Control Power Input
2.00 mm
2
(#14 AWG)
Protective Ground (Required for Safety)
2.00 mm
2
(#14 AWG)
Table 2-2:
Control Supply Terminal
Block Mating Connector
Type
Aerotech P/N
Phoenix P/N
Wire Size: AWG [mm
2
]
3-Pin Terminal Block
ECK00213
1754465
12-30 [3.3 - 0.0516]
www.aerotech.com
Chapter 2
9
Содержание BL 10-40
Страница 4: ...BL Table of Contents iv www aerotech com...
Страница 6: ...BL List Of Figures vi www aerotech com...
Страница 8: ...BL List of Tables viii www aerotech com...
Страница 10: ...x www aerotech com BL Declaration of Conformity...
Страница 16: ...BL Introduction 6 Chapter 1 www aerotech com...
Страница 38: ...BL Installation and Configuration 28 Chapter 2 www aerotech com...
Страница 54: ...BL Wiring Configurations 44 Chapter 3 www aerotech com...
Страница 68: ......