![Aerotech Automation1 XR3 Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/aerotech/automation1-xr3-series/automation1-xr3-series_hardware-manual_2863033018.webp)
Table 1-2:
Configurations and Options
Input Line Voltage
-VL1
115 VAC
-VL2
230 VAC
-VL3
100 VAC
-VL4
200 VAC
Bus Voltage 1 and Bus Voltage 2 Configurations
Bus Voltage 1 (Required)
Bus Voltage 2 (Optional)
--
--
-VB0
Not wired (Bus Voltage 2 only)
-VB1
±10 VDC (200 W Power Supply), bipolar
-VB1
±10 VDC (200 W Power Supply), bipolar
-VB2
±20 VDC (200 W Power Supply), bipolar
-VB2
±20 VDC (200 W Power Supply), bipolar
-VB3
±30 VDC (200 W Power Supply), bipolar
-VB3
±30 VDC (200 W Power Supply), bipolar
-VB4
±40 VDC (300 W Power Supply), bipolar
-VB4
±40 VDC (300 W Power Supply), bipolar
-VB5
±80 VDC (300 W Power Supply), bipolar
-VB5
±80 VDC (300 W Power Supply), bipolar
-VB7
160 VDC, unipolar
-VB7
160 VDC, unipolar
-VB8
320 VDC, unipolar
-VB8
320 VDC, unipolar
Split Bus Options
-SB0
No split, Axis 1-6 Bus Voltage 1
-SB1
Axis 1 Bus Voltage 1, Axis 2-6 Bus Voltage 2
-SB2
Axis 1-2 Bus Voltage 1, Axis 3-6 Bus Voltage 2
-SB3
Axis 1-3 Bus Voltage 1, Axis 4-6 Bus Voltage 2
-SB4
Axis 1-4 Bus Voltage 1, Axis 5-6 Bus Voltage 2
-SB5
Axis 1-5 Bus Voltage 1, Axis 6 Bus Voltage 2
Axis Control Board
Axis 1 (Required)
Axis 2-6 (Optional)
-CT0
No control board
0
No control board
-CTN
No multiplier
N
No multiplier
-CT1
Primary feedback multiplier (standard
performance)
1
Primary feedback multiplier (standard
performance)
-CT2
Primary feedback multiplier (high
performance)
2
Primary feedback multiplier (high
performance)
-CT4
Primary and auxiliary multiplier (high
performance)
4
Primary and auxiliary multiplier (high
performance)
Note: "-CT" is applied to the first axis option only. A three axis order would look like: -CT111.
Axis Amplifier
Axis 1 (Required)
Axis 2-6 (Optional)
-P0
None
P0
None
-P1
XSP3-10 PWM amplifier
P1
XSP3-10 PWM amplifier
-P2
XSP3-20 PWM amplifier
P2
XSP3-20 PWM amplifier
-P3
XSP3-30 PWM amplifier
P3
XSP3-30 PWM amplifier
-L1
XSL3-10-40 linear amplifier
L1
XSL3-10-40 linear amplifier
Note: "-" is applied to the first axis option only. A three axis order would look like: -P1P1P1.
Chapter 1: Introduction
XR3 Hardware Manual
18
www.aerotech.com
Содержание Automation1 XR3 Series
Страница 1: ...Revision 2 01 Automation1 XR3 Drive Rack HARDWARE MANUAL...
Страница 10: ...This page intentionally left blank EU Declaration of Conformity XR3 Hardware Manual 10 www aerotech com...
Страница 12: ...This page intentionally left blank Agency Approvals XR3 Hardware Manual 12 www aerotech com...
Страница 16: ...This page intentionally left blank Installation Overview XR3 Hardware Manual 16 www aerotech com...
Страница 26: ...Figure 1 3 Dimensions without Chassis Slides 1 2 2 Dimensions XR3 Hardware Manual 26 www aerotech com...
Страница 63: ...Figure 2 30 Digital Output Schematic XR3 Hardware Manual 2 6 DOUT Connector Digital Outputs www aerotech com 63...
Страница 66: ...Figure 2 33 Digital Input Schematic 2 7 DIN Connector Digital Inputs XR3 Hardware Manual 66 www aerotech com...
Страница 92: ...This page intentionally left blank 3 2 Fuse Specifications XR3 Hardware Manual 92 www aerotech com...
Страница 98: ...This page intentionally left blank Appendix C Revision History XR3 Hardware Manual 98 www aerotech com...