![Aerotech Automation1 XL5e Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/aerotech/automation1-xl5e/automation1-xl5e_hardware-manual_2863032045.webp)
2.3.4. Encoder Fault Input
The encoder fault input is for use with encoders that have a fault output. This is provided by some
manufactures and indicates a loss of encoder function. The active state of this input is parameter
configurable and the controller should be configured to disable the axis when the fault level is active. The
nominal trip voltage of the encoder fault input is +2.5 V.
Table 2-20:
Encoder Fault Input Pin on the Feedback Connector
Pin #
Description
In/Out/Bi
23
Encoder Fault Input
Input
Figure 2-21:
Encoder Fault Input Schematic (Feedback Connector)
www.aerotech.com
45
XL5e Hardware Manual
2.3.4. Encoder Fault Input
Содержание Automation1 XL5e
Страница 1: ...Revision 1 01 Automation1 XL5e High Performance Linear Digital Drive HARDWARE MANUAL...
Страница 12: ...This page intentionally left blank Safety Procedures and Warnings XL5e Hardware Manual 12 www aerotech com...
Страница 14: ...This page intentionally left blank Installation Overview XL5e Hardware Manual 14 www aerotech com...
Страница 21: ...1 2 2 Dimensions Figure 1 3 Dimensions XL5e Hardware Manual 1 2 2 Dimensions www aerotech com 21...
Страница 22: ...Figure 1 4 Dimensions EB1 1 2 2 Dimensions XL5e Hardware Manual 22 www aerotech com...
Страница 63: ...Figure 2 32 PSO Interface XL5e Hardware Manual 2 5 Auxiliary I O Connector www aerotech com 63...
Страница 82: ...Figure 3 2 Digital Outputs Schematic EB1 3 1 Digital Outputs EB1 XL5e Hardware Manual 82 www aerotech com...
Страница 98: ...This page intentionally left blank 5 2 Fuse Specifications XL5e Hardware Manual 98 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix C Revision History XL5e Hardware Manual 104 www aerotech com...