Aeropro CN45RA Скачать руководство пользователя страница 3

3

COIL ROOFING NAILER CN45RA

tool.Always ensure that the tool has stopped before putting it down after use, in the interest of safety and to
prevent possible damage to the tool/user.
Keep proper footing at all times in order to ensure correct balance.

Do not use oxygen or any other combustible or bottled gas

to power

air-powered

tools. Failure to observe this warning can cause explosion and serious personal
Use a minimum of 25

(7.6m) of hose to connect the tools to the compressor.

Failure to comply will result in serious injury or loss of life.

Risk of electric shock:

Do not expose a compressor to rain. Store it

indoors. Disconnect

the compressor from power source before servicing. Compressor must be
grounded. Do not use grounding adaptor.

Risk of personal injury:

Do not direct compressed air from the air hose toward the user or other

personnel.

Risk of inhalation:

Never directly inhale the air produced by the compressor.

Risk of bursting:

Do not adjust the pressure switch or safety valve for any reason. They have been

preset at the factory for this compressor

s maximum pressure. Tampering with the pressure switch or

the safety valve

Risk of burns:

The pump and the manifold generate high temperatures. In order to avoid burns or

other injuries, do not touch the pump, the manifold or the transfer tube while the compressor is running.
Allow the parts to cool down before handling or servicing. Keep children away from the compressor at
all times.

Risk of bursting:

Make sure the regulator is adjusted so that the compressor outlet

pressure is set lower than the maximum operating pressure of the tool. Before
starting
the compressor, pull the ring on the safety valve to make sure the valve moves
freely.Drain water from tank after each use. Do not weld or repair tank. Relieve all
pressure in the hose before removing or attaching accessories.

WARNING!

Potential hazard that could result in serious injury or loss of life.
Do not allow unskilled or untrained individuals to operate the air powered tools.
Do not use the air powered tools for any task other than that it is designed to perform.

Do not use the air tools unless you have been trained to do so. Only a qualified person should use the tool.

Locate the compressor in a well-ventilated area for cooling, and must be a minimum of 12

(31cm) away from the nearest wall.

Protect the air hose and the power cord from damage and puncture. Inspect them for weak or worn spots every week, and replace them if

necessary .

Always wear hearing protection when using the air compressor. Failure to do so may result in hearing

loss.
Do not carry the compressor while it is running.
Do not operate the compressor if it is not in a stable position.
Do not operate the compressor on a rooftop or in an elevated position that could allow the unit to fall or be tipped

over. Always replace a damaged gauge before operating the unit again.

CAUTION!

Potential hazard that may result in moderate injury or damage to equipment.

Always ensure that the tool has stopped before connecting to the air supply.

Содержание CN45RA

Страница 1: ...is not worn Damage to hearing if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintained Wear eye protection 2019 IMPORTANT Read all safety rules and operating Instructions carefully before first use it Keep this Manual for future reference TABLE OF CONTENT...

Страница 2: ...s manual carefully and understand it thoroughly before using the product the symbols listed below are used to indicate this information DANGER Potential hazard that will result in serious injury or loss of life WARRNING Potential hazard that could result in serious injury or loss of life CAUTION Potential hazard that may result in moderate injury or damage to equipment Note The word note is used t...

Страница 3: ...ay from the compressor at all times Risk of bursting Make sure the regulator is adjusted so that the compressor outlet pressure is set lower than the maximum operating pressure of the tool Before starting the compressor pull the ring on the safety valve to make sure the valve moves freely Drain water from tank after each use Do not weld or repair tank Relieve all pressure in the hose before removi...

Страница 4: ...f the tool as doing so may cause tool failure Handling and storage of oil Use with adequate ventilation Avoid contact of oil with eyes skin and clothing Avoid breathing spray or mist Store in a tightly closed container in a cool dry well ventilated area free from incompatible substances CAUTION Potential hazard that may result in moderate injury or damage to equipment Disconnect tool from the air ...

Страница 5: ...e filing a freight claim can be difficult When you are completely satisfied with the condition of the shipment you should inventory the equipment After you open the box you should find the following Model CN45RA Inventory Figure 1 Hex Wrench 3mm Hex Wrench 4mm Safety Goggles Oil Pot KEY PARTS DIAGRAM 1 Exhaust Cover 6 Magazine 2 Gun Body 7 Shingle Guide 3 Drive Guide 8 Air Inlet Plug 4 Nail Guide ...

Страница 6: ...ol WARNING Potential hazard that could result in serious injury or loss of life Keep hands and other parts of the body away from the tools discharge and working areas when connecting the air supply Failure to comply could lead to serious injury or loss of life It is recommended that a filter regulator lubricator is used and located as close to the tool as possible If a filter regulator lubricator ...

Страница 7: ...ing Nails 1 Disconnect the tool 1 from the air supply 2 Fig A 2 Grip the nail guide and knob with finger Press the knob down swing the nail guide open and open the magazine cover Fig B 3 Adjust the position of the nail holder to correspond with the nail length The nail will not feed smoothly if the nail holder is not correctly adjusted Turn the nail holder about 90 counter clockwise Move the nail ...

Страница 8: ...e same depth be sure that The air pressure to the Nailer remains constant regulator is installed and working properly The nailer is always held firmly against the workpiece If nails are driven too deep or too shallow into the workpiece adjust the nailing depth using the following instructions 1 Disconnect air hose from nailer Fig F 2 If the nails are driven too deep pull the adjuster downward and ...

Страница 9: ... tool from the compressor before adjusting clearing jams servicing maintenance relocating and during non operation Regular lubrication if your tool without using the in liner automatic oilier place 2 or 6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of continuous use depending in the characteristic of workpiece or type of fasteners Air operated tools must be...

Страница 10: ...te well can not drive fastener or operate sluggishly 1 Inadequate air supply 2 Inadequate lubrication 3 Worn or damaged O rings or seals 4 Exhaust port in cylinder head is blocked 1 Verify adequate air supply 2 Place 2 or 6 drops of oil into air inlet 3 Check and replace O rings or seal 4 Replace damaged internal parts Tool skips fasteners 1 Worn bumper or damaged spring 2 Dirt in front plate 3 Di...

Страница 11: ...11 COIL ROOFING NAILER CN45RA Explode Drawing Explode Drawing Issue date 2019 5 7 Version C 0 ...

Страница 12: ...51 Fixed Plate 1 88 Magazine Cover 1 16 Cylinder 1 52 Switch Seat 1 89 Tray Cap 1 17 Cylinder Seal Gasket 1 53 Switch Lever 1 90 Screw M4 50 1 18 Cylinder Spring 1 54 91 Spring Washer 4 1 19 O Ring 56 2 4 1 55 O Ring 2 8 1 8 1 92 Flat Washer d 4 1 20 Lower Collar 1 56 Trigger 1 93 Adjustable Lever 1 21 O Ring 47 2 4 1 57 Push Lever 1 94 Bushing 2 22 Gun Body 1 58 Push Lever Sleeve 1 95 Circlip 1 2...

Отзывы: