background image

GES – Users Manual 

 

 

 

Page 32 of 33 

A device connected to the GES can connect to other devices on the network but cannot 

communicate with the GES’s Management Processor. 

 

 

Problem: 

If the affected device has a MAC address where the last two bytes concatenated are less 

than or equal to 1500 (0x5DC), the IP stack in the Management Processor will discard 

the packet. 

 

 

 

 

Workaround: 

Change the two least significant MAC address bytes of the affected device to make them 

larger than 1500 (0x5DC). 

Содержание GES

Страница 1: ...1775 West Hibiscus Blvd Suite 200 Melbourne FL 32901 321 984 1671 www Aeronix com Gigabit Ethernet Switch GES User s Manual...

Страница 2: ...unting hardware R Kneapler SP 705 2 July 2012 001 C Fixed word order issue with Summary Status packet in Sect 7 3 2 and corrected the unit weight on pages 29 31 R Little SP 725 6 September 2012 001 D...

Страница 3: ...the menus work 8 6 3 2 Menu Header 8 6 3 3 Main Menu 9 6 3 4 Configuration Menu 10 6 4 EXAMPLE 12 7 MANAGEMENT PROCESSOR ETHERNET COMMUNICATIONS 15 7 1 NETWORK COMMUNICATIONS SUPPORTED 15 7 2 GENERAL...

Страница 4: ...a Completed 26 7 4 8 Finished Programming 27 7 4 9 Finished Programming Acknowledge 27 7 4 10 Bad CRC 27 8 SWITCH MANAGEMENT CAPABILITIES 28 9 HARDWARE MOUNTING 29 10 INDICATORS 29 11 QUALIFICATIONS 3...

Страница 5: ...ement ports Its rugged monolithic design is intended to operate in severe environments without the need for forced air cooling This document is intended to provide the information required to interfac...

Страница 6: ...lowing electrical interfaces Six Ethernet Ports 0 5 Two RS 232 Serial Ports o DEV1 Dedicated Maintenance Port for the Management Processor o DEV2 Designed to be programmed as an Ethernet to Serial Bri...

Страница 7: ...Ground 23 Port 7 C 73 Chassis Ground 24 Port 1 D 74 Chassis Ground 24 Port 7 D 74 Chassis Ground 25 Reserved 75 Port 5 D 25 28V 75 Port 11 D 26 GND 76 Port 5 D 26 Reserved 76 Port 11 D 27 Reserved 77...

Страница 8: ...sed Unused 3 4 2 Serial and Programming Ports All connections in Table 3 1 that have an Orange background are Serial Port connections The DEV1 serial port is a dedicated GES Management Processor Maint...

Страница 9: ...s if required 3 4 4 Input Power The connections shown in Table 3 1 with a Red background are Power Connections The input power requirements are as specified in MIL STD 704A Aircraft 28 VDC Category B...

Страница 10: ...7 8 Port 5 6 9 Port 6 4 10 Port 7 2 11 Port 8 3 12 Port 9 5 13 Port 10 1 14 Port 11 0 15 GES Internal Management CPU CPU Port n a 4 2 Serial Ports There are two serial ports associated with the Manag...

Страница 11: ...m either of two internal banks of flash The smaller bank is dedicated to the bootloader This allows upgrading of the GES application software in the field over the network Immediately after power up t...

Страница 12: ...th a message string Saw a NN on port 1 n where NN is a hexadecimal representation of the input character 6 3 Menus 6 3 1 How the menus work All menu selections require a single character to be input T...

Страница 13: ...port status Show the port status of the MAC ports Shows link connection status speed duplex and other information Note Port 63 corresponds to the management CPU port 6 3 3 4 2 PHY port status Show th...

Страница 14: ...N crc32 3875E0CC The management CPU supports two IP addresses This allows the GES management CPU to potentially participate in two distinct subnets The primary IP and net mask are shown as IP_address...

Страница 15: ...on At the conclusion of a successful IP address and netmask input the GES writes the configuration to flash 6 3 4 5 d set mirror destination The GES prompts for an entry 0 9 a b where external ports 1...

Страница 16: ...IB counts c go to configuration menu GES c GES Software Version 4 3 GES Bootloader Version 7 Hardware Serial Number 1002 MAC Address 00 0B D1 08 10 02 FDB Table Index 984 IP Address 0 192 168 1 100 IP...

Страница 17: ...mirror 0 11 N B N N N N N N N N N N cpu_switch_mirror N crc32 3875E0CC IP_address 0 6501A8C0 192 168 1 101 IP_address 1 64811FAC 172 31 129 100 IP_mask 0 00FFFFFF 255 255 255 0 IP_mask 1 00FFFFFF 255...

Страница 18: ...Page 14 of 33 IP_address 1 64811FAC 172 31 129 100 IP_mask 0 00FFFFFF 255 255 255 0 IP_mask 1 00FFFFFF 255 255 255 0 mirror_destination 2 switch_mirror 0 11 N B N N N N N N N N N N cpu_switch_mirror...

Страница 19: ...te order This means that fields larger than a byte will be read and written using standard access routines These routines are host to network short htons host to network long htonl network to host sho...

Страница 20: ...atus Request 0 OFF 1 Request IBIT status Word 2 Bit 2 GES Traffic Capture Mode 0 nothing 1 Begin Traffic Capture Mode Word 2 Bit 3 GES Operational Status Mode 0 OFF 1 Operational Status Mode Active Wo...

Страница 21: ...degraded Word 2 Bit 2 Overall TDR Status 0 good 1 degraded Word 2 Bit 3 Baseline Mode of Operation 0 not in Baseline Mode 1 Baseline Mode Baseline mode of operation indicates that there are no config...

Страница 22: ...Overall Phy Status Overall TDR Status 3 Port 0 PHY Status Port 1 PHY Status Port 2 PHY Status Port 3 PHY Status Port 4 PHY Status Port 5 PHY Status Port 6 PHY Status Port 7 PHY Status Port 8 PHY Stat...

Страница 23: ...Port 6 TDR Interface Status Port 7 TDR Interface Status Port 8 TDR Interface Status Port 9 TDR Interface Status Port 10 TDR Interface Status Port 11 TDR Interface Status Switch Management Processor I...

Страница 24: ...plex Setting Port 5 Duplex Setting Port 6 Duplex Setting Port 7 Duplex Setting Port 8 Duplex Setting Port 9 Duplex Setting Port 10 Duplex Setting Port 11 Duplex Setting 3 Port 0 Speed Status Port 1 Sp...

Страница 25: ...Dropped Port 5 Collisions 13 Spare 0 Port 6 Avg Bandwidth 14 Port 6 Dropped Port 6 Collisions 15 Spare 0 Port 7 Avg Bandwidth 16 Port 7 Dropped Port 7 Collisions 17 Spare 0 Port 8 Avg Bandwidth 18 Por...

Страница 26: ...s that the P0 P11 and CPU port mirroring details will be updated with the contents of this packet c When set this bit indicates that the Network Parameters will be updated with the contents of this pa...

Страница 27: ...d Opcode 3 with the a b and c bits all reset the current GES configuration can be queried without effecting the current configuration a always 0 b always 0 c always 0 Primary IP Address The GES manage...

Страница 28: ...port GES Reboot In order to do a GES application update the unit must be power cycled to cause the bootloader to listen for the UDP packets necessary to program a new GES application into the 512K fla...

Страница 29: ...new GES Application to program into the NBB flash 7 4 3 Erase NBB Flash Acknowledge 1 1 1 1 1 1 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 Length 2 0 Opcode 105 1 Direction From bootloader This is the first GES...

Страница 30: ...ld always be even 7 4 6 Program NBB Data Acknowledge 1 1 1 1 1 1 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 Length 2 0 Opcode 108 1 Direction From bootloader The bootloader immediately responds with this message...

Страница 31: ...fails CRC32 the bootloader sends a Bad CRC UDP message 7 4 9 Finished Programming Acknowledge 1 1 1 1 1 1 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 Length 2 0 Opcode 111 1 Direction From bootloader The bootload...

Страница 32: ...nk Aggregation 802 3ad allows two or more links to be trunked to increase the total bandwidth and provide a failsafe if one of the links fails A high speed non blocking QoS switch fabric with support...

Страница 33: ...Allen head screws with a black oxide coating The rectangular mounting pattern for the attachment points is 3 55 x 7 71 as shown in Figure 9 1 The overall external dimensions are 8 25 L x 5 15 W x 1 3...

Страница 34: ...od 514 5 Gunfire Vibration Gunfire Sine Sweeps Up to 15G MIL STD 810B Method 515 1 Category B Acoustical Noise 140db MIL STD 810F Method 516 5 Procedure VI Bench Handling MIL STD 810F Method 516 5 Pro...

Страница 35: ...onent is a part shall be suspended from the date Seller receives the item until the date the item is replaced or corrected and this warranty shall apply to such replacement or corrected items furnishe...

Страница 36: ...GES s Management Processor Problem If the affected device has a MAC address where the last two bytes concatenated are less than or equal to 1500 0x5DC the IP stack in the Management Processor will dis...

Страница 37: ...s Aeronix offers an extensive line of Engineering Services including the creation and implementation of custom management configurations for the GES Visit the Aeronix web site at www Aeronix com for a...

Страница 38: ...GES Users Manual 1775 West Hibiscus Blvd Suite 200 Melbourne FL 32901 321 984 1671 www Aeronix com Copyright Aeronix Inc 2012...

Отзывы: