background image

The following are some tips and suggestions to help you troubleshoot a few common problems 

that might arise when setting up the HiveAP 340:

• 

Make sure that you connect the larger antennas to the 2.4-GHz connectors, and the smaller 

ones to the 5-GHz connectors.

• 

If you manage the HiveAP through HiveManager Online and it does not show up on the 

Monitor > Access Points > HiveAPs page, do the following:

 

Check if the HiveAP serial number is listed in the ACL (access control list) on the Aerohive 

redirection server. Log in to myhive.aerohive.com, and then click

 Redirector > Monitor 

> HiveAP Access Control List

). If not, click 

Enter

, type its serial number in the HiveAP 

Serial Number field, and then click 

Save

. When done, reboot the HiveAP.

 

– Check connectivity to HiveManager Online:

ping redirector.aerohive.com 

(Check connectivity from the HiveAP network)

capwap ping redirector.aerohive.com 

(Check connectivity through CAPWAP)

 

Ensure that any intervening firewalls allow one of the following sets of services from the 

HiveAP to HiveManager Online:

CAPWAP (UDP 12222), SSH (TCP 22), and HTTPS (TCP 443)

or 

HTTP (TCP 80) and HTTPS (TCP 443)

• 

If a wireless client cannot form an association with an SSID, check that the client is within 

range and that it is configured to use the same authentication method as the SSID. For 

example, if the client is configured to use Open or WEP authentication but the SSID is 

set for WPA or WPA2, the client will not be able to associate with the HiveAP. To see the 

security settings for an SSID, log in to HiveManager, click 

Configuration > SSIDs > 

ssid_name

 

> Advanced Access Security Settings, and look at the SSID access security type, the key 

management method, and the encryption method.

• 

If the client associates and authenticates itself, but the HiveAP cannot forward traffic, 

check that the HiveAP is assigning the correct user profile and, if so, that it is also assigning 

the correct VLAN. To see the user profile and VLAN that a HiveAP assigns a client, log in to 

HiveManager, click 

Monitor > Clients > Active Clients >

 

client_mac_address.

 Check the user 

profile attribute and VLAN. If those are correct, then check that the client has received 

its network settings through DHCP. To check connectivity to a DHCP server, click 

Tools > 

VLAN Probe

, choose the HiveAP with which the client is associated from the HIveAP drop-

down list, enter IDs for the VLAN range that you want to check. Click 

Start

 to send a DHCP 

DISCOVER message, and see if it elicits a response. Also check that the VLAN configuration for 

the port on the connecting switch is correct.

To remove all settings and return the configuration to its factory default settings, enter the

 

reset config 

command or use a pin to press the Reset button on the chassis and hold it down 

for at least 10 seconds.

©

2011 Aerohive Networks, Inc.

Aerohive

®

 and HiveAP

®

 are U.S. registered 

trademarks of Aerohive Networks, Inc.
P/N 330025-05 Rev. A

Technical Documentation 

Aerohive provides various technical documents for its products. For information about CLI 

commands, see the CLI reference guides available in HTML format. For information about 

HiveManager and HiveAP hardware and software topics, see the 

Aerohive Deployment Guide

 

(PDF). The deployment guide contains information about HiveAPs and HiveManager appliances, 

WLAN deployment considerations, and detailed configuration instructions for commonly used 

features. To access Aerohive product documentation, visit www.aerohive.com/techdocs.

HiveManager Help System

The HiveManager Help system contains a wealth of information about all the features you can 

configure through HiveManager. To access it, click the Help icon in the upper right corner of 

the GUI. A Help topic that pertains to the currently active GUI page appears. To see other Help 

topics, use the table of contents to browse the system or the search tool to find information 

about a specific subject.

Support Site

Access technical support services, documentation, and software at www.aerohive.com/

support/login.html. After registering for an account, you will receive a user name and 

password to enter when logging in. You can contact Support for assistance through the web site 

or by phone (+1 408.510.6100 or 866.365.9918).

Training

Aerohive offers courses covering the Aerohive cooperative control concepts, the installation 

and configuration of Aerohive products, and how to troubleshoot issues and optimize 

performance. For more information, visit www.aerohive.com/support/training.html.

Aerohive also offers CBT (computer-based training) modules. CBTs are online flash tutorials 

that explain Aerohive concepts and walk you through configuration procedures step by step. 

You can use the CBTs to familiarize yourself with the HiveManager GUI and learn how to 

configure HiveAPs. Aerohive CBTs are available for free online at 

www.aerohive.com/techdocs. 

Where to go for more information

Deployment and Configuration Tips

Using the mounting plate and track clips, you can mount the HiveAP 340 to the tracks of a 

dropped ceiling grid. Using just the mounting plate, you can mount the HiveAP to any flat surface 

that can support its weight (3.3 lb., 1.5 kg). Both mounting options are explained below.

Mounting the HiveAP 340

Note

:   In addition to these methods, you can also mount the HiveAP 340 on a table using the 

set of four rubber feet that ship with the product. Simply peel the rubber feet off the 

adhesive sheet and press them against the underside of the HiveAP in its four corners.

To mount the HiveAP 340 to a standard 1"-wide track (2.54 cm) in a dropped ceiling, you need the 

mounting plate, two track clips, and two Keps nuts that ship with the HiveAP 340. You also need a 

drill, a wrench, and—most likely—a ladder. For narrower tracks 1/2" to 9/16" wide (1.27 - 1.43 

cm), 

use the clips available separately in the AH-ACC-9-16-CLIP-KIT accessory. 

Nudge the ceiling tiles slightly away from the track to clear some space. Attach the track clips to 

the ceiling track, and then fasten the mounting plate to the clips. When you have the mounting 

plate in the correct location, cut or drill a hole in the ceiling through which you can then pass the 

Ethernet and power cables. 

2

Through the oblong opening in the 

plate, drill a hole in the ceiling tile 

(not shown). Then pass one or both 

Ethernet cables through the hole, 

and if you plan to supply power 

from an AC power source rather 

than through PoE, pass the power 

cable through as well.

3

Insert the mounting plate over the 

screws attached to the track clips, 

and use the Keps nuts to fasten 

the plate firmly to the threaded 

studs on the clips. Use a wrench to 

tighten the nuts firmly to the bolts 

and secure the plate to the track.

1

Attach the HiveAP 340 to the mounting plate and connect the cables. (Note: You can tie the 

cables to the tie points (small arched strips) on the mounting plate to prevent them from being 

pulled out of their connections accidentally.)

4

Press the track clips against the 

ceiling track and swivel them until 

they snap into place, gripping the 

edges of the track. If necessary, 

slide one or both of the clips 

along the track to position them 

at the proper distance (2 1/4" or 7 

cm) to fit through the holes in the 

mounting plate.

With the HiveAP 340 upside down, align its port side with the bottom end of 

the plate. Push the HiveAP upward, inserting the four tabs on the plate into 

the four slots on the HiveAP. Slide the HiveAP toward the bottom end of the 

plate, locking the tabs in the slots.

5

Attach the antennas and connect the cables to complete the installation.

When done, adjust the ceiling tiles back into their former position.

You can use the mounting plate to attach the HiveAP 340 to any surface that supports its weight, 

and to which you can screw or nail the plate. First, mount the plate to the surface. Then, through 

one of the larger openings in the plate, make a hole in the wall so that you can pass the cables 

through to the HiveAP.

Finally, attach the device to the plate, and connect the cables.

With the two wings at the sides of the 

plate extending away from the surface, 

attach the mounting plate to a secure 

object such as a wall or beam. Use #8 

screws for the oblong holes, and #10 

for the larger round ones.

Cut or drill a hole through one of the 

openings in the mounting plate to pass 

the cables through to the HiveAP 340.

Insert the tabs on the mounting plate 

into the slots on the underside of the 

HiveAP 340. Then push the HiveAP 340 

downward to lock it in place.

Attach the antennas and connect the 

cables to the HiveAP 340.

Depending on how the device is powered 

and how it connects to the network, 

connect a power cable and one or two 

Ethernet cables.

Note:   There are various holes through which you can 

screw or nail the plate in place. Choose the 

two or three that best suit the object to which 

you are attaching it.

1

Mount the HiveAP 340 on a wall as explained below.

(side view)

2

3

4

Locking the HiveAP 340

To lock the HiveAP 340 to the mounting plate, use either a Kensington lock or the lock adapter 

that is included with the mounting kit and a small padlock (not included). To use a Kensington 

lock, loop the cable attached to the lock around a secure object, insert the T-bar component 

of the lock into the device lock slot on the HiveAP, and then turn the key to engage the lock 

mechanism. To use the lock adapter, follow the steps below:

Insert the security screw through 

the hole in the HiveAP 340 and 

thread it into the hole in the 

mounting plate.

1

With the insert bit in a screw driver, 

tighten the screw into place, securing 

the HiveAP to the mounting plate.

2

Ceiling Mount

Surface Mount

Track Clips

Ceiling Track

2 1/4" (7 cm)

Mounting Plate

HiveAP 340 (shown transparent for clarity)

Tab 

inside 

slot.

Tab 

locked in 

place.

(side view)

Tab

Slot

Ceiling
Mounting Plate
HiveAP 340

(cables pass through holes in 

the mounting plate and ceiling)

Drill a hole in the ceiling tile 

and feed cables through here.

(worm’s eye view with ceiling tiles removed for clarity)

 

HiveAP 340

HiveAP 340

Mounting Plate

Wall

5 GHz (A)

5 GHz (B)

5 GHz (C)

Insert a lock  

through the opening.

HiveAP 340

Mounting Plate

Rotate the lock 

adapter clockwise.

Отзывы: