Using the mounting plate and track clips, you can mount the HiveAP 320 to the tracks of a 

dropped ceiling grid. Using just the mounting plate, you can mount the HiveAP to any flat surface 

that can support its weight (2 lb., 0.9 kg). Both mounting options are explained below.

Mounting the HiveAP 320

Note

:   In addition to these methods, you can also mount the HiveAP 320 on a table using the 

set of four rubber feet that ship with the product. Simply peel the rubber feet off the 

adhesive sheet and press them against the underside of the HiveAP in its four corners.

To mount the HiveAP 320 to a standard 1"-wide (2.54 cm) track in a dropped ceiling, you need the 

mounting plate, two track clips, and two Keps nuts, all of which ship with the HiveAP 320. You 

also need a screwdriver and—most likely—a ladder. For narrower tracks that are 1/2" to 9/16" wide 

(1.27 - 1.43 cm), use the clips available separately in the AH-ACC-9-16-CLIP-KIT accessory.

Track Clips

a

Insert the screws through 

the mounting plate and 

thread them into the track 

clips, fastening the clips 

loosely to the plate.

Note

:   The mounting plate is depicted as 

transparent to show the position 

of the two screws below the holes 

in the plate.

b

Adjust the track clips so 

that their tabs can pass 

on either side of a ceiling 

track.

c

Ceiling Track

Press the clips against the 

ceiling track and swivel 

them until they snap into 

place, gripping the edges 

of the track.

1

When you have the mounting plate in the correct location, cut or drill a hole in the ceiling 

through which you can then pass the Ethernet and power cables. Pass the cables through the 

hole and attach them to the HiveAP 320, leaving some slack so that you can easily maneuver 

the HiveAP into place, attaching it to the mounting plate.

Note

:  For clarity, the power and Ethernet cables are not shown in the illustration.

2

Nudge the ceiling tiles slightly away from the track to clear some space  Attach the 

track clips and mounting plate to the ceiling track.

Snap!

Snap!

Push HiveAP

With the HiveAP 320 upside down, align the round tab and security screw hole extension 

on the mounting plate with the keyhole opening and security screw cavity on the HiveAP 

320, and press the HiveAP upward.

3

Pushing from the LED end of the HiveAP, slide it 

toward the bottom end of the plate until the two 

rippled tabs on the mounting plate snap over the 

nubs on the underside of the HiveAP.

When done, adjust the ceiling tiles back into their former position.

You can use the mounting plate to attach the HiveAP 320 to any surface that supports its weight, 

and to which you can screw or nail the plate. First, mount the plate to the surface. Then, through 

the large opening in the lower part of the plate, make a hole in the wall so that you can pass the 

cables through to the HiveAP.

Finally, attach the device to the plate, and connect the cables.

Orient the mounting plate as shown and 

attach it to a secure object such as a 

wall, post, or beam. Use #6 screws.

Cut or drill a hole through the large space 

near the bottom of the mounting plate to 

pass the cables through to the HiveAP 320.

Insert the tabs on the mounting plate into 

the slots on the underside of the HiveAP 

320. Then push the HiveAP 320 downward 

to lock it in place.

Connect the cables to the HiveAP 320.

Depending on the deployment, you might 

connect one or two Ethernet cables and a 

power cable.

Note:  There are a variety of holes through which you can screw or nail the plate in place. 

Choose the two or three that best suit the object to which you are attaching it.

Note:  Because Ethernet cables fit snugly in the ETH0 and ETH1 ports, try to use cables that 

do not have protective boots over their connectors.

1

Mount the HiveAP 320 on a wall as explained below.

If you do not pass the cables through a hole, you can run them along the wall between the wall 

and the mounting plate. To create space for the cables, attach the rubber feet to the mounting 

plate before attaching it to the wall.

(side view)

HiveAP 320

Mounting 

Plate

wall

(side view)

Rubber Feet

Cables

side of wall

HiveAP

 320

Mounting Plate

Attach the four rubber feet here.

Run all the cables between 

the mounting plate and 

the wall before fastening 

the plate in place with the 

screws. The rubber feet 

provide clearance for the 

cables to pass.
Connect the cables to the 

ETH0 and ETH1 ports and 

power connector.

Attach the HiveAP 320 to 

the mounting plate.

2

3

4

1

2

3

4

Locking the HiveAP 320

To lock the HiveAP 320 to the mounting plate, use the security screw, which is included in the 

mounting kit. You also need a Torx tri-wing torsion insert bit for size #1 tri-wing security screws 

and a screw driver that will accept the bit. The correct bits are available from Aerohive in sets 

of three (AH-ACC-SEC-BIT-3PK).

Security Screw

Insert the security screw through the hole 

in the HiveAP 320 and begin to thread it 

into the hole in the mounting plate.

1

With the insert bit in a screw driver, 

tighten the screw into place, securing the 

HiveAP to the mounting plate.

2

Screws

(below mounting 

plate)

Mounting Plate

(with track clips attached)

Ceiling Mount

Surface Mount

Technical Documentation 

Aerohive provides various technical documents for its products. For information about CLI 

commands, see the CLI reference guides available in HTML format. For information about 

HiveManager and HiveAP hardware and software topics, see the 

Aerohive Deployment Guide

 

(PDF). The deployment guide contains information about HiveAPs and HiveManager appliances, 

WLAN deployment considerations, and detailed configuration instructions for commonly used 

features. For instructions about setting up a HiveAP to manage other HiveAPs through the 

HiveUI, see the 

Aerohive QuickStart: HiveAP as a Management AP

 (PDF). To access Aerohive 

product documentation, visit www.aerohive.com/techdocs.

HiveManager Help System

The HiveManager Help system contains a wealth of information about all the features you can 

configure through HiveManager. To access it, click the Help icon in the upper right corner off 

the GUI. A Help topic that pertains to the currently active GUI page appears. To see other Help 

topics, use the table of contents to browse the system or the search tool to find information 

about a specific subject.

Support Site

Access technical support services, documentation, and software at www.aerohive.com/

support/login.html. After submitting an account registration, you will be sent a user name and 

password to enter when logging in. You can contact Support for assistance through the web 

site, by email ([email protected]

), or by phone (+1 408.907.3186 or 866.365.9918).

Training

Aerohive offers courses covering the Aerohive cooperative control concepts, the installation 

and configuration of Aerohive products, and how to troubleshoot issues and optimize 

performance. For more information, visit www.aerohive.com/support/training.html.

Aerohive also offers CBT (computer-based training) modules. CBTs are online flash tutorials 

that explain Aerohive concepts and walk you through configuration procedures step by step. 

You can use CBTs to familiarize yourself with the HiveManager GUI and learn how to configure 

HiveAPs. Aerohive CBTs are available for free online at www.aerohive.com/techdocs. 

Where to go for more information

The following are some tips and suggestions to help you troubleshoot a few common problems 

that might arise when setting up the HiveAP 320:

• 

If the client fails to authenticate to an SSID using a PSK (preshared key), check that the 

PSK on the client matches that on the HiveAP and reset one or both keys if necessary.

• 

If you manage the HiveAP through HiveManager Online and it does not show up on the 

Monitor > Access Points > HiveAPs page, do the following:

 

– Check if the HiveAP is still listed in the staging server (click 

Navigate MyHive > 

Staging Server > Monitor > HiveAP

). If so, select it, and then click 

Redirect

 to move 

it to your HiveManager Online system.

 

– Check connectivity to HiveManager Online:

ping staging.aerohive.com

ping hm-online.aerohive.com

 

Ensure that any intervening firewalls allow one of the following sets of services from 

the HiveAP to HiveManager Online:

CAPWAP (UDP 12222), SSH (TCP 22), and HTTPS (TCP 443)

or 

HTTP (TCP 80) and HTTPS (TCP 443)

• 

If a client cannot form an association, check that the client is within range and that it is 

configured to use the same authentication method as the SSID. For example, if the client 

is configured to use Open or WEP authentication but the SSID is set for WPA or WPA2, the 

client will not be able to associate with the HiveAP. To see the security settings for an 

SSID, click 

WLAN > Configure WLAN/SSID

, and look at the key management, encryption 

and authentication methods, and SSID type listed in the table at the bottom of the page.

• 

If the client associates and authenticates itself, but the HiveAP cannot forward traffic, 

check that the HiveAP is assigning the correct user profile and, if so, that it is also 

assigning the correct VLAN. To see the user profile and VLAN that a HiveAP assigns a 

client, enter

 show ssid <string> station

, and check the UPID (user profile ID) and 

VLAN columns. If those are correct, then check that the client has received its network 

settings through DHCP. To check connectivity to the DHCP server, make a console or SSH 

connection to the HiveAP, send a probe, and see if it elicits a response:

 interface 

mgt0 dhcp-probe vlan-range <vlan1> <vlan2>

Also check that the VLAN 

configuration for the port on the connecting switch is correct.

To remove all settings and return the configuration to its factory default settings, enter the

 

reset config 

command or use a pin to press the Reset button on the chassis and hold it 

down for at least 5 seconds.

Deployment and Configuration Tips