29
EEPROM Parameters
The OEM Host can program various parameters that are stored in EEPROM which become active after a power-on reset.
Table 9 - EEPROM Parameters, gives the locations and descriptions of the parameters that can be read or written by the
OEM Host. Factory default values are also shown. Do not write to any EEPROM addresses other than those listed
below. Do not copy a transceiver’s EEPROM data to another transceiver. Doing so may cause the transceiver to
malfunction.
Table 9 - EEPROM Parameters
Parameter
EEPROM
Address
Length
(Bytes)
Range
Default
Description
Product ID
0x00
40
40 bytes - Product identifier string. Includes revision
information for software and hardware.
Stop bit Delay
0x3F
1
0x00 –
0xFF
0xFF
For systems using the RS-485 interface or Parity, the serial
stop bit might come too early (especially at slower interface
baud rates). Stop bit Delay controls the width of the last bit
before the stop bit occurs.
0xFF = Disable Stop bit Delay (12us)
0x00 = (256 * 1.6us) + 12us
1 – 0xFE = (value * 1.6us) + 12us
Channel Number
0x40 1
0x00
–
0x2F
AC4790-1x1: 0x00
AC4790-200: 0x00
AC4790-1000: 0x10
Set 0 = 0x00 – 0x0F (US/Canada): AC4790-1x1/200
Set 1 = 0x10 – 0x2F (US/Canada): AC4790-1x1/1000
Set 3 = 0x30 – 0x37 (US/Canada): AC4790-1x1-200
(Australia): AC4790-1x1/200/1000
Baud Rate Low
0x42 1
0x00
–
0xFF
0xFC
Low Byte of the interface baud rate. Default baud rate is
57,600.
Baud Rate High
0x43 1 0x00
0x00 Always
0x00
Control 0
0x45
1
0x00
Settings are:
bit-7 – 0
bit-6 – DES Enable
0 = Disable Encryption
1 = Enable Data Encryption
bits-5 – 0: 0
Transmit Retries
0x4C 1
0x01
–
0xFF
0x04
Maximum number of times a packet is sent out when
Addressed Packets is selected.
Broadcast
Attempts
0x4D 1
0x01
–
0xFF
0x04
Total number of times a packet is sent out when Broadcast
Packets is selected.
Stale
Count Reload
0x4F 1
0x01
–
0xFF
0x40
Determines the amount of time a transceiver will keep
another transceiver (say transceiver A) active in its Radio
Table. This counter is reset every time a packet is received
from that transceiver (A).
Control1
0x56
1
01000011b (0x43)
Settings are:
bit-7 – AeroComm Use Only
bit-6 – 1
bit-5 – 0
bit-4 – Auto Destination
0 = Use Destination Address
1 = Automatically set Destination to last radio received from
bit-3 – 0
bit-2 – RTS Enable
0 = RTS Ignored
1 = Transceiver obeys RTS
bit-1 – Duplex
0 = Half Duplex
1 = Full Duplex
bit-0 – Auto Config
0 = Use EEPROM values
1 = Auto Configure Values