IMPORTANT SAFETY INFORMATION  

 

 

 

 

 

 

 

 

About this User Manual 

Congratulations on your purchase of this GermZone® 100 high‐performance air purification and 
disinfection system.  Please study this user manual carefully to familiarize yourself with the special 
features and functions of your system prior to use and keep it in a safe place for future reference. 
 
WARNING: NOT SUITABLE FOR USE WITH SOLID‐STATE SPEED CONTROLS. 
 
AVERTISSEMENT: NE CONVIENT PAS A DES REGULATEURS DE VITESSEA SEMI‐CONDUCTEURS. 
 
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE TO WATER OR RAIN. 
 
AVERTISSEMENT: POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE NE PAS EXPOSER À L'EAU OU À 
LA PLUIE. 
 
The following symbols are found in your user’s manual or on labels affixed to the unit itself: 
 

Note:

  This means pay particular attention. Notes contain helpful suggestions. 

 

 CAUTION:

 This symbol means be careful. You are capable of doing something that might 

result in injury, death, or damage to equipment. 

 

 WARNING:

 This symbol means UV Radiation. You may be exposed to UV Radiation that 

could cause eye or skin injuries.  

 

General Cautions & Electrical Safety    

 

 

 

 

 

 

 

                          

  Always disconnect the power from this air cleaner by unplugging the power cord before 

adding or removing parts and before cleaning. 

  Do not use the unit in wet environments.  If, for any reason, the unit gets moisture of any 

kind inside stop use and contact customer service. 

  Do not operate in the presence of flammable gasses or liquids. 

  The unit must NOT be used for the abatement of asbestos or other hazardous materials. 

  Shock and mechanical hazard: Be certain to unplug the unit before performing any service 

or opening the cabinet. 

  Prior to changing the filter or UV‐C lamps be sure to turn the unit off, then unplug the 

power cord. 

Содержание GermZone 100

Страница 1: ...OM GermZone100 01 Rev D GERMZONE 100 Made in USA from US and Int l Components...

Страница 2: ...FORMATION WARRANTY 15 GermZone reserves the right to change specifications contained in this document at any time without prior notice If you have questions about the use of this product contact your...

Страница 3: ...Note This means pay particular attention Notes contain helpful suggestions CAUTION This symbol means be careful You are capable of doing something that might result in injury death or damage to equip...

Страница 4: ...ts intended purpose of air cleaning in non industrial environments Do not use this unit in areas with very high concentrations of dust or powder to prevent the danger of dust explosions Do not use att...

Страница 5: ...NING The GermZone 100 contains two 16 watt ultraviolet lamps The lamps are designed to disinfect the airstream from viruses molds and bacteria The lamps automatically turn on when the unit is turned o...

Страница 6: ...idered and reduced as much as possible Ventilation is important to air quality and a source of fresh air for the room should be available As the unit s filter becomes saturated soiled or obstructed th...

Страница 7: ...f the unit You may need to slide the plate down and pull away from the back of the unit 3 If installation of a 120 volt AC grounded wall receptacle is required ensure the receptacle is installed suffi...

Страница 8: ...e at one predetermined speed for maximum efficiency in producing clean air Beside the power switch is an indicator light that indicates when the ultraviolet lamps are working properly If the indicator...

Страница 9: ...ne 100 is operating in an excessively contaminated environment changing the filter more frequently is advised UV Lamps Replace the UV lamps P N L1 0040 1 every 8000 hours of operation or approximately...

Страница 10: ...unplug from the wall outlet 2 Remove the fan cover on the same side as the power switch by gently prying the top of the cover away from the case of the unit A flat bladed instrument such a flat head s...

Страница 11: ...mpting to replace the UV lamps and confirm that unit is completely re assembled with the filter in place before plugging back in and powering the unit on 1 Power the GermZone 100 off and unplug the po...

Страница 12: ...Page 12 of 15 OM GermZone100 01 Rev D 4 Gently remove the four pronged plugs from both lamps by sliding straight off 5 Remove the two 2 nuts securing the lamp cover to the chassis...

Страница 13: ...tal housing as this may cause breakage UV Lamps like all fluorescent lamps contain mercury and must be handled carefully 9 Reverse the above procedure to install the new lamps and reassemble During re...

Страница 14: ...ardous waste Please refer to local regulations and laws for proper handling and disposal Discarding Used Lamps UV Lamps like all fluorescent lamps contain mercury and must be handled and disposed of p...

Страница 15: ...and implied warranties for this product including the warranties of merchantability and fitness for a particular purpose are hereby disclaimed Some states do not allow the exclusion of implied warran...

Отзывы: