background image

 

PN 101953 

 

 

 

Figure 4 

 

 

 

Figure 5 

 

 

 

Figure 6 

 

connections are tight, pinch the large air line after the black “tee” 
(on the tank side of the tee) to deadhead the pump. The sound 
output of the pump will change. If the light goes out the air switch 
is o.k. and go to step 4. If the light does not go out call Aero-
Stream®. 

4.

      

Plug the float into the alarm box. Open the septic tank cover. 

Make sure the float switch is hanging completely vertically in the 
tank. If not, using a stick, push the float downward until the cord 
and float are vertical. If the light goes out go to step 5. 

5.

      

Allowing the float to hang from its’ bracket, adjust the float 

switch clamp on the mast upward until the light goes out. 

6.

      

If the light does not go out call Aero-Stream®. 

 

Function Configuration 
 

The Aero-ALERT™ can be configured to defeat the audible signal 

or defeat the air switch to make the unit function as a high water 
alarm only. 

 
1. 

To defeat the audible signal gently slide the green connector 

from the terminal and leave loose inside enclosure (figure 6).

 

2. 

To defeat the air switch gently slide the yellow connector from 

the terminal and leave loose inside enclosure (figure 6).

 

 

 
Options

 
P/N: 101859 - DC Power supply to operate the Aero-ALERT™ on 

120 VAC. 

 
 
 
 

 

 

 

Figure 7 

 

To Float 
Switch 