Installer: Leave this manual with the homeowner.   

INSTALL GRILLE   

Install  ceiling  material  to  complete  the  ceiling  construction.  Then,  cut 
around the fan housing.   
First,  insert  the  sensor  plug  into  the  plug  base  on  the  power  box  then 
install the grille.   
To attach the grille assembly to the fan housing, pinch the grille springs on 
the  sides  of  the  grille  assembly,  and  position  the  grille  into  the  housing 
with  the  grille  springs  in  the  appropriate  slots.  Gently  push  the  grille 
assembly towards the ceiling to secure.   

SERVICE PARTS   

PART 

PART NAME 

Qty. 

Grille Assembly (includes part 2) 

12   

Grille Spring 

Power box 

11 

Motor Plate 

Motor 

10   

Blower Wheel 

8   

Wire Panel / Harness Assembly 

Hanger Bar Kit (long) 

Wiring plate 

10 

Housing 

11 

Hanger Bar Kit (short) 

12 

Damper / Duct Connector 

13 

Motion system 

Nut, Hex Lock 

Washer 

d   

Screw 

4   

Isolator 

c   

Screw 

3   

*  Blower Assembly includes part 6, 5, d, 4, c, b, a. Replacement 
installation:  Remove  the  screw  (part  c),  then  take  out  the  motor 
plate (part 4) from the housing  (part 10) by pushing down the rib 
in the plate while pulling  out on the side of the housing. Replace 
broken parts. 

 

 
a   
2   

13 

WARNING: 

Before replacing, be sure

 to turn off power at power source.

 

WARRANTY   

 

4   

READ AND SAVE THESE INSTRUCTIONS   

This warranty covers all defects in workmanship or materials for: 
The mechanical and electrical parts contained in this product for a period of 72 months from the date of purchase. You must keep and be able to 
provide  your  original  sales  receipt  as  proof  of  date  of  purchase.  This  warranty  is  covered  to  the  original  retail  purchaser  of  this  product  only.  The 
manufacturer will replace any mechanical or electrical part that proves defective in normal household use for a period of 72 months.   
 
THIS WARRANTY DOES NOT COVER: 
• Damages from improper installation.   
• Damages from shipping. 
• Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance. 
• Damages from service by persons other than a licensed electrician.   
• Does not cover any labor or transportation charges related to the repair of this product. 
 
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 
 
The  remedy  provided  in  this  warranty  is  exclusive  and  is  granted  in  lieu  of  all  other  remedies.    This  warranty  does  not  cover  incidental  or 
consequential  damages.  Some  states  do  not  allow  the  exclusion  of  incidental  or  consequential  damages,  so  this  limitation  may  not  apply  to  you. 
Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This warranty gives you specific 
legal rights; you may also have other rights, which vary from state to state.

 

 

 

 

VSF110DMH-S 

Содержание VSF110DMH-S

Страница 1: ...te speed control device 13 The fan must not be installed in a ceiling thermally insulated to a value greater than R40 CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point upward for wall application 3 To avoid motor bearing da...

Страница 2: ...adjustment toward or 4 Turn on power and check operation by turning on the shower or other humidity source until the fan turns on 5 Repeat above steps if necessary When the temperature changes humidity sensor values may deviate MOTION SENSOR Sensing distance will be impacted by the body s own mass i e a smaller person will require more remote sensing distance Turn on the sensor switch and the syst...

Страница 3: ...anger bar A Hanger bar long 21 1 4 in to 23 1 2 in 540mm 597mm Hanger bar long 4 Mount to I joist Screw B Screw A 5 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using duct tape not included secure all the ductwork connections so that they are air tight Insulated flexible duct is recommended for t...

Страница 4: ...s warranty covers all defects in workmanship or materials for The mechanical and electrical parts contained in this product for a period of 72 months from the date of purchase You must keep and be able to provide your original sales receipt as proof of date of purchase This warranty is covered to the original retail purchaser of this product only The manufacturer will replace any mechanical or ele...

Отзывы: