aero pure VSF110DMH-S Скачать руководство пользователя страница 1

 

BATHROOM FAN   

www.aeropurefans.com   

MODEL: VSF110DMH-S   

WARNING   

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ 
THE FOLLOWING PRIOR TO INSTALLING THE FAN:   

1

.  Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have  questions,  contact  the  manufacturer.   

2

.  Before 

servicing or cleaning unit, switch power off at service panel to prevent power from being switched on accidentally. When the  service 
disconnect cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.   

3

. Installation work 

and electrical wiring must be done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated 
construction  codes  and  standards.   

4

.  Sufficient  air  is  needed  for  proper  combustion  and  exhausting  of  gases  through  the  flue 

(chimney)  of  fuel  burning  equipment  to  prevent  backdraft.  Follow  the  heating  equipment  manufacturer’s  guideline  and  safety 
standards  such  as  those  published  by  the  National  Fire  Protection  Association  (NFPA),  and  the  American  Society  for  Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.   

5

. When cutting or drilling into wall or ceiling, 

do  not  damage  electrical  wiring  and  other  hidden  utilities.   

6

.  Ducted  fans  must  always  be  vented  to  the  outdoors. 

7

.  Unit  is 

acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit  (ceiling 
installation only).   

8

. This unit must be grounded.   

9

. Not for use in kitchens.   

10

. Install fan at least 2.5 m (8.2 feet) above the floor.   

11

. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or 

ceilings or into attics, crawl spaces, or garages. This unit is appropriate for wall installation in a non-wet application.   

12

. WARNING: 

To  reduce  the  risk  of  fire  or  electric shock,  do  not  use  this  fan  with  any  solid-state speed control device.   

13

.  The  fan must  not  be 

installed in a ceiling thermally insulated to a value greater than R40. 

CAUTION   

1

. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2

. This product is designed for 

installation in ceilings up to a 12/12 pitch (45 degree angle).    Duct connector must point upward for wall application. 

3

. To avoid motor 

bearing  damage  and  noisy  and/or  unbalanced  impellers,  keep  drywall  spray,  construction  dust,  etc.  off  power  unit. 

4

.  Please  read 

specification label on product for further information and requirements.   
 

*This manual in electronic format may be downloaded from our company website or obtained from the dealer. 

 

 

CLEANING & MAINTENANCE   

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting 
brush attachment.   

The motor is permanently lubricated and never needs oiling. 

 

OPERATION   

Power box   

The control box, located inside the fan housing, has three separate 
adjustments: 

Toggle switch 

(1) The time delay knob which is adjustable from 5 to 60 minutes and switches the 
humidity sensor knob.   

Humidity   

Sensor knob 

12    3 

 

(

2) The humidity sensor for setting the proper relative humidity level in the room. 

Switch   

(3) The toggle switch will adjust the upper fan speed setting from 80 to 120 CFM 
using a 4” duct or 90 to 140 CFM using a 6” duct. 

position 

1 2 3 

1 2 3 

1 2 3 



1 2 3 

1 2 3 

1 2 3 

1 2 3 

Air deliver (CFM) 

80  90  110 120  90  110  120  140 

1 2 3 

Duct 

diameter (inches) 

4" 

4"  4" 

4" 

6"  6" 

6"  6" 

Both 4" and 6" duct adaptors are included

is the position of switch 

Times of operation: 
(a) When someone enters then leaves the room. 
(b) When humidity rises above a user-adjustable set point (50-100% Relative 
Humidity (RH)). 

 

Switch 

position 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

1 2 3  1 2 3 

1 2 3 

1 2 3 

Airflow   

Duct   

diameter   

4" 

4"    4"    4"    6"    6"    6"    6"   

(inches)   

Factory setting: 110CFM ( ) with 6" duct   

HVI Certified performance based on HVI Procedures 915, 
916, and 920.   
Other airflow reference performance based on HVI 
Procedures 915, 916, and 920.   

READ AND SAVE THESE INSTRUCTIONS   

Installer: Leave this manual with the homeowner.   

1   

 

 

 

  Timer 
delay knob 

Содержание VSF110DMH-S

Страница 1: ...te speed control device 13 The fan must not be installed in a ceiling thermally insulated to a value greater than R40 CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point upward for wall application 3 To avoid motor bearing da...

Страница 2: ...adjustment toward or 4 Turn on power and check operation by turning on the shower or other humidity source until the fan turns on 5 Repeat above steps if necessary When the temperature changes humidity sensor values may deviate MOTION SENSOR Sensing distance will be impacted by the body s own mass i e a smaller person will require more remote sensing distance Turn on the sensor switch and the syst...

Страница 3: ...anger bar A Hanger bar long 21 1 4 in to 23 1 2 in 540mm 597mm Hanger bar long 4 Mount to I joist Screw B Screw A 5 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using duct tape not included secure all the ductwork connections so that they are air tight Insulated flexible duct is recommended for t...

Страница 4: ...s warranty covers all defects in workmanship or materials for The mechanical and electrical parts contained in this product for a period of 72 months from the date of purchase You must keep and be able to provide your original sales receipt as proof of date of purchase This warranty is covered to the original retail purchaser of this product only The manufacturer will replace any mechanical or ele...

Отзывы: