aero pure ABF110DHG5 Series Скачать руководство пользователя страница 5

WIRING DIAGRAM

FEATURES

Model: ABF110DHG5 

ABF110DHG6

Model: ABF110DHL5 / ABF110DHL6 

Motor

Ground

Live

Neutral

Green

Black

White

P
C
B

Yellow-

green

Red
Red

Signal
Signal

Power switch

Control switch

Fan body

Junction box

Motor

Ground

Live

Neutral

Green

Black

White

P
C
B

Light Body

Blue

Brown
White

Live (Light)

Live(N. Light)

Neutral

Yellow-

green

Red
Red

Signal
Signal

Power switch

Control switch

Fan body

Junction box

●CFM-Selection. Choose 50-80-110CFM; default is high speed.

 

●Multi-Speed- Switch allows fan to run at continuous lower speed to

meet Indoor Air Quality. For example, when Flow-Selection setting is 

80CFM, Multi-Speed can be chosen 0, 50, 60, or 70CFM as a 

low speed.

●Delay- Switch for time delay setting. Setting range is 0, 5, 10, 20, 

30, 45, or 60 minutes.

●Air Trimming- Switch allows fine-tuning of air volume when the 

actual airflow is lower than set.

 

050

60708090100

0 5

1020304560

Time(min)

50 80 110

L

H

Air Trimming

Air Volume(CFM)

Time delay

Air trimming

Flow-Selection

Multi-Speed

5

INSTRUCTIONS:

Turn the power on.

When the control switch is turned on,

 

the fan will run continuously at high speed only.  The power 

    must be on before turning the control switch on. The sensors will not work and Time Delay Switch 

    does not apply to this mode.

When the control switch is turned off, the fan will run at chosen low speed on Multi-Speed switch 

    continuously, and boost to the high speed when the sensor detects an increase in Relative 

    Humidity. The fan will run at high speed for amount of time selected from the Time Delay Switch 

    before returning to lower speed when the Relative Humidity falls below the set point.

Содержание ABF110DHG5 Series

Страница 1: ...NANCE CLEANING PRACTICAL GUIDE TO INSTALLATION SPECIFICATIONS WARRANTY 02 02 02 03 04 05 05 06 07 11 13 14 14 15 Thank you very much for purchasing our bath fan Please read the instructions carefully before attempting to install operate or service our ventilating fan Failure to comply with instructions could result in personal injury or property damage Please retain this booklet for future referen...

Страница 2: ...models are listed by ETL under ETL file No 5011292 These bath fan models use a Sirocco fan driven by a brushless DC motor The motor is designed to have an extended service life with reduced energy consumption The grille covering the fan body is a spring loaded quick attach type A damper for preventing air counterflow is provided The suspension bracket assembly can be used for both new and retrofit...

Страница 3: ...f this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are ETL listed for tub and shower enclosures Not to be installed in a ceiling thermally insulated to a value greater than R40 This is required for installation in Canada only Do not install this ve...

Страница 4: ...per Frame assy Knockout plate Junction box 1 2 3 4 5 6 7 8 9 10 11 12 13 2 4 Model ABF110DHG6 Series ABF110DHL6 Series Model ABF110DHG5 Series ABF110DHL5 Series 3 7 8 98 4 7 8 123 5 4 5 147 3 4 5 97 10 2 5 265 10 1 4 260 12 1 8 308 7 1 3 186 3 5 14 5 13 330 10 1 4 260 12 1 8 308 3 7 8 98 4 7 8 123 5 4 5 147 3 4 5 97 10 2 5 265 13 330 7 1 3 186 3 5 14 5 ...

Страница 5: ...g Setting range is 0 5 10 20 30 45 or 60 minutes Air Trimming Switch allows fine tuning of air volume when the actual airflow is lower than set 0 5060708090 1 0 0 0 510203045 6 0 Time min 50 80 110 L H Air Trimming Air Volume CFM Time delay Air trimming Flow Selection Multi Speed 5 INSTRUCTIONS Turn the power on When the control switch is turned on the fan will run continuously at high speed only ...

Страница 6: ...then the fan starts to run or boosts to high speed when concentration level is over 1000PPM The fan runs in low speed after a period of time delay or stops working when concentration level is less than 800PPM 3 0 8 0 Humidity RH CO2 INSTALLATION PLUG IN DEVICES Humidity Sensor Module is included with this fan Contact Aero Pure to purchase CO2 Sensor Module Position A is for CO2 Sensor module posit...

Страница 7: ...0 mm A B If the spacing L is 16 24 inches 406 610 mm use the suspension bracket assembly If the spacing L is 12 inches 305 mm on joists please follow the installation step as Fig 1 Secure 4 screws ST4X30 at flange of frame to the joists Then follow steps 6 to 9 of Installation I page 6 8 to complete the installation Please wear gloves during the installation work CAUTION 11 4 5 22 1 2 300 579 4 Sc...

Страница 8: ...n Fig 3 Fig 3 Joist Screws ST4X20 Place the adaptor on the bracket assembly as indicated position and install it by using 2 self drilling screws ST4X30 Fig 4 Unit inches mm Bend down 8 tabs for positioning as Fig 2 a and unfold the bracket assembly as Fig 2 b 1 2 3 4 Active part Fig 4 2 Screws ST4X30 Position of adaptor Fig 5 Push the fan body upwards until the fan body is stopped by the buckle on...

Страница 9: ...res to the ventilating fan wires Fig 7 II then attach it to fan body Follow all the local electrical safety codes as well as the National Electrical Code NEC IMPORTANT Fig 7 Fig 8 Attach cable clamp to Knockout Plate Knockout Plate mounts to outside of Housing and may be oriented as desired Connect wires III Screw from Parts Bag Black Red Green Wire nuts White Nuts 8 Finish ceiling work Align ceil...

Страница 10: ...he plug connector into the housing of the lighting unit and insert the other mounting spring into the slot as shown and mount grille to fan body Fig 10 Fig 11 10 For grille with a light refer to the following installation method Fig 10 Before turning on the light make sure the connector is at the correct position If not the lighting will not work The claw of connector must be secured to the rib co...

Страница 11: ...spring into the slot as shown and mount grille to fan body Fig 12 11 For grille with a module refer to the following installation method Fig 12 1 Put the folded bracket assembly into ceiling hole then follow step 3 4 of Installation I NEW CONSTRUCTION page 8 to complete the bracket installation Fig 13 Unit inches mm Fig 13 A B Screws ST4x20 10 3 5 270 10 3 5 270 INSTALLATION II RETROFIT ...

Страница 12: ...5 or 6 circular duct is needed to connect to relevant part of adaptor Fig 14 Remove the knock out plate and secure conduit or wire protector nut to knock out hole Fig 15 Refer to wiring diagram on page 5 Using UL approved wire nuts connect house power wires to the ventilating fan wires Fig 15 then fix it to fan body Follow all the local electrical safety codes as well as the National Electrical Co...

Страница 13: ...ing to fan motor 1 2 3 CAUTION Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan Do not immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C Remove grille Squeeze mounting spring and pull down carefully Fig 17 Grille 4 5 6 Reinstall grille Fig 20 Remove dust and dirt from fan body using a vacuum cleaner Fig 19 Using a c...

Страница 14: ...exible duct helps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Using the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the du...

Страница 15: ...censed electrician Does not cover any labor or transportation charges related to the repair of this product THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover inc...