13
Aermec code 6755521_01 11.11
ANK 025-085H
Data in compliance with the EN 14511-2 Standard
Condenser inlet water temperature
30°C
Condenser outlet water temperature
35°C
External air temperature
7°C d.b./6° C w.b.
Sound power
Aermec determines sound power values on the basis of meas-
urements made in compliance with the 9614-2 Standard, in
agreement with that requested by Eurovent certification.
Sound pressure
Sound pressure in free field conditions on reflective surface
(directivity factor Q=2) at 10 mt from the external surface of
unit, in compliance with ISO 3744 regulations.
A -15/W 35
ANK020
ANK030
ANK040
ANK045
ANK050
ANK085
Hea ng capacity
H
kW
3.730
4.690
5.748
6.084
7.159
7.910
HP-HA
3.559
4.633
5.674
5.994
7.052
8.067
Input power
H
kW
1.840
2.555
3.111
3.323
3.565
4.030
HP-HA
1.890
2.586
3.131
3.394
3.646
4.108
COP
H
W/W
2.027
1.836
1.848
1.831
2.008
1.963
HP-HA
1.883
1.792
1.812
1.766
1.934
1.964
Water flow rate
ALLES
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALLES
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALLES
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALLES
68.0
70.5
70.5
70.5
70.5
70.5
A 7/W 45
Hea ng capacity
H
kW
7.980
9.741
11.882
13.639
14.906
17.450
HP-HA
7.741
7.611
11.733
13.428
14.686
16.835
Input power
H
kW
2.310
3.112
3.792
4.182
4.436
5.120
HP-HA
2.373
3.150
3.815
4.271
4.536
5.172
COP
H
W/W
3.455
3.130
3.133
3.261
3.360
3.408
HP-HA
3.262
2.416
3.075
3.144
3.238
3.255
Water flow rate
ALLES
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALLES
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALLES
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALLES
68.0
70.5
70.5
70.5
70.5
70.5
A 2/W 45
Hea ng capacity
H
kW
5.757
7.878
9.181
10.622
10.671
12.018
HP-HA
5.679
7.773
9.065
10.459
10.513
11.832
Input power
H
kW
2.236
3.006
3.674
4.031
4.263
4.843
HP-HA
2.285
3.043
3.697
4.147
4.359
4.931
COP
H
W/W
2.575
2.621
2.499
2.635
2.503
2.482
HP-HA
2.485
2.554
2.452
2.522
2.412
2.400
Water flow rate
ALLES
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALLES
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALLES
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALLES
68.0
70.5
70.5
70.5
70.5
70.5
A -7/W 45
Hea ng capacity
H
kW
4.559
4.872
5.963
7.290
8.066
9.199
HP-HA
4.454
4.758
5.888
7.105
7.874
8.992
Input power
H
kW
2.205
2.928
3.575
3.971
4.180
4.774
HP-HA
2.255
2.966
3.597
4.058
4.279
4.865
COP
H
W/W
2.068
1.664
1.668
1.836
1.930
1.927
HP-HA
1.975
1.604
1.637
1.751
1.840
1.848
Water flow rate
ALLES
l/h
1470
1840
2260
2550
2800
3222
Pressure drops
H
kPa
28
16
24
18
22
27
Useful head pressure
HP-HA
55.0
63.0
51.0
74.3
65.7
56.2
Air flow rate
ALLES
m
3
/h
3500
8000
8000
7500
7500
7500
Sound pressure
ALLES
dB(A)
37.0
39.5
39.5
39.5
39.5
39.5
Sound power
ALLES
68.0
70.5
70.5
70.5
70.5
70.5
EHPA 400V/3N/50Hz technical data
Содержание ANK 020 H
Страница 81: ...81 Aermec code 6755530_03 9 2011 ANK 025 085H ...
Страница 82: ...82 Aermec code 6755530_03 9 2011 ANK 025 085H ...
Страница 83: ...83 Aermec code 6755530_03 9 2011 ANK 025 085H ...