156
NUMERIC DISPLAYS (cont'd):
Range:
Resolution:
Time to Desaturate
23:50 max to 0:00 hr:min*
1 minute
(* starting 10 min. after the dive)
Temperature
0 to 140°F (-9 to 60°C)
1°
Tank Pressure
0 to 5000 PSI (345 BAR)
5 PSI (1 BAR)
Time of Day
0:00:00 to 23:59:59 hr:min
1 minute
FREE Countdown Timer
59:59 to 0:00 min:sec
1 second
Out of Range (- - -)
=> 330/399 FT (100/120 M)
Violation Countdown Timer
23:50 to 0:00 hr:min (after violation)
BAR GRAPHS
Nitrogen Loading Bar Graph:
segments
No Decompression zone
1 to 7
Decompression zone
8 (all)
Oxygen (O2) Bar Graph:
segments
Normal zone
1 to 4
Danger zone
5 (all)
Variable Ascent Rate Indicator:
Deeper than 60 FT (18 M)
60 FT (18 M) & Shallower
Segments
Ascent Rate =
Segments
Ascent Rate =
Displayed
FPM
MPM
Displayed
FPM
MPM
0
0-20
0-6
0
0-10
0-3
1
21-30
6.1-9
1
11-15
3.1-4.5
2
31-40
9.1-12
2
16-20
4.6-6
3
41-50
12.1-15
3
21-25
6.1-7.5
4
51-60
15.1-18
4
26-30
7.6-9
5
60 +
18 +
5
30 +
9 +
SPECIFICATIONS (CONTINUED)
Содержание Elite T3