Aeris Elite T3 Скачать руководство пользователя страница 1

ELITE T3

DIVE COMPUTER

OPERATING MANUAL

Содержание Elite T3

Страница 1: ...ELITE T3 DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...ns Tank Gas 1 2 3 g Symbols AIR TIME TIME NDC TIME O2 TIME TAT TIME SURF h NIBG i O2BG j Symbol PSI or BAR Pressure k Icon Ascend Arrow l Icon degrees Temperature m Icon Descend Arrow n Symbol STOP TI...

Страница 3: ...AND ALPHA NUMERIC GRAPHICS 19 ALPHA NUMERIC DISPLAYS 20 Tank Pressure Display 20 Depth Displays 20 Air Time Remaining Display 20 Date Time and Temperature Displays 21 FREE Dive Mode Displays 21 SURFA...

Страница 4: ...larm 41 Set PO2 Alarm 42 SET U GROUP UTILITIES 43 Set Wet Activation 44 Set Units of Measure 45 Set NORM Safety Stop 46 Set Conservative Factor 47 Set Backlight Duration 48 Set Sampling Rate 49 Set TM...

Страница 5: ...aining ATR 80 Air Time Remaining Alarm 81 ASCENT RATE ALARM 82 CONTROL OF DISPLAYS 83 WET CONTACTS 84 NORM TYPE DIVE MODES 85 NORM NO DECOMPRESSION DIVE MODE 86 NORM Dive No Deco Safety Stop 89 DECOMP...

Страница 6: ...O DECO DURING A FREE DIVE 136 REFERENCE 137 UPLOADING SETTINGS AND DOWNLOADING DATA 138 PC Compatibility Requirements 139 CARE AND CLEANING 140 INSPECTIONS AND SERVICE 140 BATTERY REPLACEMENT 142 INST...

Страница 7: ...ed trademarks trade names and service marks of AERIS All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Air Time Remaining U S P...

Страница 8: ...gital Device pursuant to Part 15 of FCC Rules Title 47 of the Code of Federal Regulations These rules are designed to provide reasonable protection against harmful interference in a commercial or resi...

Страница 9: ...u must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well as general product information I...

Страница 10: ...iarwithpriortodivingwithyourEliteT3 Rememberthattechnologyisnosubstituteforcommonsense andadivecomputeronly providesthepersonusingitwithdata nottheknowledgetouseit INTERACTIVE CONTROL CONSOLE TheInter...

Страница 11: ...escentto5FT feet 1 5M meters regardlessofwhatsurfacescreenisdisplayedatthetime WARNING When Wet Activation is set OFF the Elite T3 must be activated by push button prior to the first dive of a new ser...

Страница 12: ...se SELF orforchecking1or2Bud dies TankPressure s ThesettingremainsfixeduntilchangedintheNORM GAUGSET Umenu AUDIBLE ALARM MostwarningsituationsthatactivatetheAudibleAlarmwhileoperatinginNORMor GAUGMode...

Страница 13: ...DepthSetPointselected DiveTimeRemainingattheSetPointselected ElapsedDiveTimeattheSetPointselected HighPO2of1 60ATAortheSetPointselected HighO2of300OTU singleordailyexposure NitrogenLoadingBarGraphatth...

Страница 14: ...s3times FreeDiveModeCountdownTimerreaches0 00 3beeps3times DuringthefollowingNORMDivesituations the10secondAudibleAlarmwillnotturnoff whenacknowledged AscendingabovearequiredDecompressionCeilingStopDe...

Страница 15: ...tion IfvoltageoftheEliteT3decreasestotheWarninglevel 2 75volts theBatteryiconwillappearonSurfacedisplay screens Fig 2a asanindicationthattheBatteryshouldbe changedpriortocommencingaseriesofdives Ifth...

Страница 16: ...stheSbuttonfor2 secondswhileviewingtheNORMorGAUGSurfaceMain Display thenreleaseit Asthebuttonisdepressed theVT3 sReceiverwillactivate 2secondslater theVT3 sBatterystatuswillbedisplayed for3seconds Fig...

Страница 17: ...elower7representNo Decompressionstatusandthe8thatthetopindicatesaDecompressioncondition WhentheEliteT3issettooperateinNORMNitroxmode the5segmentO2BarGraph O2BG Fig 7b willrepresentoxygenaccumulation D...

Страница 18: ...tprovidesa visualrepresentationofascentspeed i e anascentspeedom eter ThesegmentsoftheVARIrepresenttwosetsofspeeds whichchangeatareferencedepthof60feet 18meters Refer tothechartforsegmentvalues WARNIN...

Страница 19: ...rface Mode ChecksarenotmadeiftheunitisWET Foraconnectiontobemade theInter faceCableispluggedintotheEliteT3 sDataPortandpluggedintoaPCUSBPort To establishtheconnection thePCprogrammustberunning Whenthe...

Страница 20: ...des Duringdives theCurrent Depth display Fig 9b andMaxi mum Depth whichisaccessedasanAlternateDisplay Fig 10a indicateDepthsfrom0to399FT 120M inincrementsof 1FT 1M DuringaNoDecompressionSafetyStop the...

Страница 21: ...Primary Time display atthebottomofthescreen hasthe largestdigitsofthedisplay Fig 12a Anothertime display Fig 12b islocatedinthemiddlerow Bothdisplaysare identifiedbythesymbolTIME ThereisanAlternateDis...

Страница 22: ...d values of the information represented to avoid any possible misunderstanding that could result in error You must also understand the icons symbols and alpha numeric messages presented The Informatio...

Страница 23: ...ARNING Prior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendatio...

Страница 24: ...ltSurfaceMainscreenis displayed pressingandholdingtheMbuttonfor2seconds stepsthroughtheoperatingmodeSurfaceMainscreens Fig 15 NORMMAIN GAUGMAIN FREEMAIN TheOperatingModeselected NORM GAUG orFREE willr...

Страница 25: ...titudeLevelgraphic SEA orEL2throughEL13 andWET iftheunitiswet eachOn3secondsthen1 4secondblank BatteryiconifanEliteT3LowBatteryWarningCondition exists flashingifTooLow TankPressureandsymbolPSI orBAR i...

Страница 26: ...N screen thenanother2secondpresswillaccesstheFREESURFMAINscreen NORMSURF GAUGSURF FREESURF DepressingtheSbuttonfor2secondswhileviewingtheNORMSURFscreenwill activatetheEliteT3 sReceiverandaccessaseries...

Страница 27: ...theStatusscreen s willdisplayNotAvailable TRANSMITTER STATUS informationincludes Fig 19A B GraphicsTMT1 thenTMT2andTMT3 identifyingthe reportingTransmitter andbAt GraphicGood orLo orNotAvAil ifnotact...

Страница 28: ...scan alsobeset changedusingthePCSettingsUploadprogram FO2 SetF entriesmustbemadeusingonlythepushbuttons SET F GROUP FO2 Set F Sequence SETF FO2GAS1 FO2GAS2 FO2GAS3 FO2Default DepressingtheAandSbuttons...

Страница 29: ...O250 DEFAULTaftersubsequentrepetitive divesuntil24hourselapseafterthelastdive ortheFO250 DEFAULTisturnedOFFin theSetFO250 DEFAULTON OFFMODE WhentheFO250 DEFAULTissetOFF theEliteT3willremainsetatthelas...

Страница 30: ...rfaceIntervalhaselapsed IfFO2forGAS1issetfor21 itwillremainsetfor21 forthatseriesofdivesuntilset forahighernumericalvalue IftheFO250 DEFAULTissetOFF FO2forGAS2and3willremainattheirrespective SetPoints...

Страница 31: ...nifthebuttonishelddepressed PressingandholdingtheSbuttonwillresumethescrollfrom 32 Fig 22 through50 thenstopatAIR or21 PressingandreleasingtheSbuttonwilladvanceFO2in incrementsof1 perpressofthebutton...

Страница 32: ...0 evenifthebuttonishelddepressed DepressingtheSbuttonwillresumethescrollthrough100 thenstopatAIR or21 ortheGAS1setting PressingandreleasingtheSbutton 2seconds willadvanceFO2inincrementsof 1 perpressof...

Страница 33: ...onishelddepressed DepressingandholdingtheSbuttonwillresumethescrollthrough100 thenstopat AIR or21ortheGAS2setting PressingandreleasingtheSbutton 2seconds willadvanceFO2inincrementsof 1 perpressofthebu...

Страница 34: ...nis pressedforaperiodof2minutesoperationwillrevertto theNORMorGAUGSURFMAINscreen SET A GROUP NORM GAUG ALARMS Set A Sequence SETA Audible Depth EDT NIBG DTR TurnPressure EndPressure PO2 TheSETAGroupca...

Страница 35: ...ig 27 GraphicAUD SetPointgraphicON orOFF flashing PressingandreleasingtheSbutton 2seconds willtogglebetweenONandOFF PressingandreleasingtheAbuttonmomentarily 2seconds willsavethesetting and oradvancet...

Страница 36: ...duntilitis released PressingandreleasingtheAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSET EDT ElapsedDiveTime ALARMscreenwiththeSetPoint flashing PressingandreleasingtheAbuttonmo...

Страница 37: ...onduntilitisreleased PressingandreleasingtheAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSET NIBG NitrogenLoadingBarGraph ALARMscreenwith theSetPointflashing Pressingandreleasingth...

Страница 38: ...tonmomentarily 2 seconds willsavethesettingand oradvancetotheSET DTR DiveTimeRemaining ALARMscreenwiththeSet Pointflashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheothe...

Страница 39: ...theAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSET TURNPRESSUREALARMscreenwiththeSetPointflashing PressingandreleasingtheAbuttonmomentarilyand repeatedly 2secondseach willstepthro...

Страница 40: ...ointsat arateof4SetPointsperseconduntilitisreleased PressingandreleasingtheAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSET ENDPRESSUREALARMscreenwiththeSetPointflashing Pressingan...

Страница 41: ...heAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSET PO2ALARMscreenwiththeSetPointflashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheotherSETAscreens D...

Страница 42: ...eof4SetPointsperseconduntilitisreleased PressingandreleasingtheAbuttonmomentarily 2 seconds willsavethesettingand oradvancetotheSETA screen DepressingtheAandSbuttonssimultaneouslyfor2 secondswillsavet...

Страница 43: ...gsforWetActivation Units andBacklightDuration IthasaseparateSamplingRate fixedata1secondintervalnotaffectedbytheSETU setting DepressingtheAandSbuttonssimultaneouslyfor6 secondswhiletheNORMorGAUGSURFMA...

Страница 44: ...reenwiththeSetPointflashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheotherSETUscreens DepressingtheAandSbuttonssimultaneouslyfor2 secondswillsavethesettingandreverttoth...

Страница 45: ...dvancetotheSET SAFETYSTOPscreenwiththeTimeSetPointflashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheotherSETUscreens DepressingtheAandSbuttonssimultaneouslyfor2 seconds...

Страница 46: ...CONS ConservativeFactor screenwiththeSetPointflashing PressingandreleasingtheSbuttonmomentarily 2secondseach willstepthrough theStopDepthSetPointsof10 15 and20FT or3 4 5 and6M PressingandreleasingtheA...

Страница 47: ...onrepeatedly 2 secondseach willstepthroughtheotherSETUscreens DepressingtheAandSbuttonssimultaneouslyfor2 secondswillsavethesettingandreverttotheSETUscreen DepressingtheMbuttonfor2secondsorifnobuttoni...

Страница 48: ...etotheSET SAMPLINGRATEscreenwiththeSetPointflashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheSETUscreens DepressingtheAandSbuttonssimultaneouslyfor2 secondswillsavethes...

Страница 49: ...ET TMT1screenwiththeSetPoint flashing PressingandreleasingtheAbuttonrepeatedly 2 secondseach willstepthroughtheotherSETUscreens DepressingtheAandSbuttonssimultaneouslyfor2 secondsshallsavethesettingan...

Страница 50: ...n IfONisselected thefirst left digitoftheCodewillflash PressingandreleasingtheSbuttonrepeatedly 2seconds each willincreasetheFirstDigitfrom0to9inincrements of1 DepressingtheSbuttonwillscrollthroughthe...

Страница 51: ...PressingandreleasingtheAbutton 2seconds willaccepttheFourthDigitofthe Codeand oradvancetotheFifthDigitwhichwillbeflashing PressingandreleasingtheSbuttonrepeatedly 2secondseach willincreasethe FifthDig...

Страница 52: ...gtheAandSbuttonssimultaneouslyfor2 secondswillsavethesettingandreverttotheSETU screen DepressingtheMbuttonfor2secondsorifnobuttonis pressedforaperiodof2minutesoperationwillrevertto theNORMorGAUGSURFMA...

Страница 53: ...repeatedly 2seconds each willincreasetheFirstDigitfrom0to9inincrements of1 DepressingtheSbuttonwillscrollthroughtheSetPointsat arateof4persecond PressingandreleasingtheAbutton 2seconds will accepttheF...

Страница 54: ...itofthe Codeand oradvancetotheFifthDigitwhichwillbeflashing PressingandreleasingtheSbuttonrepeatedly 2secondseach willincreasethe FifthDigitfrom0to9inincrementsof1 DepressingtheSbuttonwillscrollthroug...

Страница 55: ...achtime willincreasetheFirstDigitfrom0to9in incrementsof1 DepressingtheSbuttonwillscrollthroughtheSetPointsat arateof4persecond PressingandreleasingtheAbutton 2seconds will accepttheFirstDigitoftheCod...

Страница 56: ...singandreleasingtheAbutton 2seconds willaccepttheFourthDigitofthe Codeand oradvancetotheFifthDigitwhichwillbeflashing PressingandreleasingtheSbuttonrepeatedly 2secondseach willincreasethe FifthDigitfr...

Страница 57: ...imultaneouslyfor8 secondswhiletheNORMorGAUGSURFMAINscreenis displayed willaccessSETTidentifiedbythegraphicSETT Fig 46 DepressingtheMbuttonatanytimefor2secondsandifno buttonispressedduringaperiodof2min...

Страница 58: ...onrepeatedly 2secondseach willstepthroughtheTime DateSettings bypassingthose thatdon trequiresetting SET TIME Hour and Minute ThegraphicAmorPmwillbedisplayedwhen12HourFormat hasbeenselected Depressing...

Страница 59: ...6to2049 withleapyearcorrections PressingandreleasingtheAbuttonmomentarily 2sec willsavetheYearSetPoint and oradvancetoSETMONTHwiththeSetPointflashingandthegraphicMNTH replacingthegraphicYEAR Depressin...

Страница 60: ...r1A DepressingtheAandSbuttonssimultaneouslyfor2 secondswillreverttotheSURFMAINscreen DepressingtheMbuttonfor2secondswillreverttothe SURFMAINscreen Ifnobuttonispressedduringaperiodof2minutes theunit wi...

Страница 61: ...nif theMbuttonispressedfor2secondsorafter2minutes withnobuttonaction NORM PLAN MODE AERIS strongly recommends that you review the Pre Dive Planning Sequence PDPS prior to every NORM dive to help you P...

Страница 62: ...o190FT 9to57M ortheMaximumDepththatwill allowtheoreticalNoDecompressionDiveTimeofatleast1 minutebaseduponthepreviousdiveprofilesinaseriesof repetitivedivesandtakingintoaccountdescentandascentrates of6...

Страница 63: ...seconds willadvancetoLOG MODE Afteradiveismade itwilladvancetoFLYMODE DepressingtheMbuttonfor2seconds orifnobuttonis pressedduringa2minuteperiod operationwillrevertto theNORMSURFMAINscreen PLAN MODE L...

Страница 64: ...2secondseachtime toincreasethePlannedDepthin incrementsof10FT 3M displayingtheinformationone screenatatime DepressingandholdingtheMbuttonfor2secondsto reverttotheNORMSURFMAINscreen FLY MODE TimetoFlyi...

Страница 65: ...accessFLYMODE GAUGSURFMAIN ALT FLY TIME TO FLY informationincludes Fig 54 GraphicFLYandsymbolTIME CountdownTime hr min BatteryiconifaEliteT3LowBatteryWarningCondition exists flashingifTooLow Pressinga...

Страница 66: ...tdive TheSATscreenisnotdisplayedafteraViolationDive DesaturationrequiringTimesgreaterthan24hourswilldisplay23 IntheeventthatTimetoDesaturatestillremainsattheendof24hours theadded timewillbezeroed Duri...

Страница 67: ...ORMorGAUGSURFMAINscreen Ifnobuttonispressedduringa2minuteperiod theunit willreverttotheNORMorGAUGSURFMAINscreen PressingtheSbuttonwillactivatetheBacklight NORM GAUG LOG MODE LOGMODEdisplaysinformation...

Страница 68: ...playedwillaccess theLOGMODE NORMSURFMAIN PLAN FLY SAT LOG or pressingandreleasingtheAbutton2times 2secondseachtime whiletheGAUG SURFMAINscreenisdisplayedwillaccesstheLOGMODE GAUGSURFMAIN FLY LOG 10min...

Страница 69: ...ttoNORMorGAUGSURFMAINscreen DepressingandholdingtheMbuttonfor2secondsorifnobuttonispressedduringa 2minuteperiodoperationwillreverttotheNORMorGAUGSURFMAINscreen PressingtheSbuttonwillactivatetheBacklig...

Страница 70: ...tdive andgraphicF orC SymbolsDIVEandTIMEandElapsedDiveTime hr min SymbolsTIMEandSURFACE Pre diveSurfaceInterval hr min 10 through23 fortimes greaterthan9 59 hr min blankforDive1ofaseries MaximumDeptha...

Страница 71: ...entingGAS1 SymbolNITROX PressingandreleasingtheSbuttonmomentarily 2 seconds buttonwilladvancetothepreviousdive sLOG PREVIEWscreen DepressingtheMbuttonfor2secondsorifnobuttonis pressedduringa2minuteper...

Страница 72: ...eenisdisplayedwillaccessHISTORY GAUGSURFMAIN ALT FLY LOG HISTORY PressingandreleasingtheAbuttonmomentarily 2 seconds willadvancetothe NORMorGAUGSURFMAINscreen DepressingtheMbuttonfor2secondsorifnobutt...

Страница 73: ...hsymbolsFT orM andMAX PressingandreleasingtheSbuttonmomentarily 2 seconds buttonwilladvancetotheNORMorGAUGSURF MAINscreen DepressingtheMbuttonfor2secondsorifnobuttonis pressedduringa2minuteperiodopera...

Страница 74: ...No Decompression Dive Time Remaining hr min TIME O2 or O2 Dive Time Remaining hr min TIME TAT or Ascent Time plus Deco Stop Times hr min TIME SURF Elapsed Surface Interval Time hr min if NORM or GAUG...

Страница 75: ...NING Prior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations...

Страница 76: ...76 Transmitter Signal Reception Guide Best Reception Area Poor Reception Area Poor Reception Area Poor Reception Area Poor Reception Area Poor Reception Distance greater than 6 feet 2 meters...

Страница 77: ...heTMT Bestreceptionisachievedwhenthe EliteT3iswithin3feet 1meter oftheTMT WheninstalledintothehighpressureportsoftheRegulatorFirst Stages theTMTsmustbepositionedsothattheyfacehorizon tallyoutwardfromt...

Страница 78: ...antpiecesofinformationonAERISdive computersistheDiveTimeRemainingnumericdisplay TheElite T3constantlymonitorsNoDecompressionstatus Oxygen Accumulation andBreathingGasConsumptionRate TheDiveTimeRemaini...

Страница 79: ...umerically alongwiththesymbolsTIMEandNDC Fig 63a andgraphi callyastheNitrogenLoadingBarGraph Fig 63b AsyouascendfromDepthfollowingadivethathasapproached theNoDecompressionLimit theNIBGsegmentswillrece...

Страница 80: ...xygenTimeRemaining OTR willthenappearasthe DiveTimeRemaining DTR display Fig 64b assignifiedbythe symbolsTIMEandO2 AsOxygenAccumulationcontinuesto increase segmentswilladdtotheO2BG Air Time Remaining...

Страница 81: ...ed duringsetup EndPressureAlarmSetting ATR identifiedbythesymbolsAIRandTIME Fig 65a canbe viewedwhenanAlternateDisplayisaccessedduringdive modes IntheeventthatATRbecomeslessthanNoDecoand O2Time itwill...

Страница 82: ...urfacewith300PSI 20BAR pressurestillinyourTank ASCENT RATE ALARM AlarmsassociatedwithAscentRatearebasedupon2setsof speedswhichchangeatareferencedepthof60FT 18M WARNING At depths greater than 60 FT 18...

Страница 83: ...SbuttonisusedtoactivatetheSmartGloBacklight Thedisplaywillbeilluminatedaslongasthebuttonisdepressed plustheBacklight Durationtimethathasbeenset 0 5 or10seconds foramaximumof20seconds TheBacklightwilln...

Страница 84: ...tactsarethepinsofthePCInterfaceDataPortandthe stemsofthePushButtons AslongasthecontactsarebridgedontheSurface thegraphic WETwillalternatewiththegraphicsNORMandSEA orEL2to EL13 ontheNORMSURFMAINscreen...

Страница 85: ...rior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as we...

Страница 86: ...ondstoacknowledgeand silenceAlarms NORM DIVE NO DECO MAIN Display Default informationprovidedincludes Fig 69 NIBGrepresentingNitrogenLoading VARIwhileascending O2BG ifanyduringNitroxdives TankPressure...

Страница 87: ...IVEMAINscreenisdisplayed pressthe Mbuttonfor2secondstoaccesstheTMT2 3USEscreen toentertheGasSwitchmenuorBuddyPressureCheck NORM DIVE NO DECO ALT 1 Display informationprovidedincludes Fig 70 DayoftheWe...

Страница 88: ...dTIME TankiconrepresentingtheGASselected 1 2 or3 SymbolNITROX ifsetforNitrox MaxDepthwithiconsFT orM andMAX Press releasetheAbutton 2sec toviewALT3 ThedisplaywillreverttotheMAINDisplayafter3seconds un...

Страница 89: ...ITROX CurrentDepthandsymbolFT orM ThedisplaywillreverttotheMAINDisplayafter3seconds NOTE The Alternate Displays cannot be ac cessed during the time when an Alarm is sound ing NORM DIVE NO DECO SAFETY...

Страница 90: ...xForxxM valueoftheStop Depthset scrollingatthetop NIBGrepresentingNitrogenLoading VARIifascending O2BG ifanyduringNitroxdives TankPressurewiththePSI orBAR icon ifaTMTisactive andlinked SymbolsSTOPandT...

Страница 91: ...lscrolleach3 4secondOnand1 4secondOff Fig 74 untilacknowledgedorfor10seconds unlesssetOFF DepresstheAbuttonfor2secondstoacknowledge silence theAudibleAlarm TheUPArrowwillflashifyouaregreaterthan10FT 3...

Страница 92: ...hindicateduntilthenext shallowerStopDepthappears Then youcanslowlyascendto butnotshallowerthan thatindicatedCeilingStopDepth DECO STOP MAIN Display Default informationprovided includes Fig 75 Graphics...

Страница 93: ...ssionceilings Stops andverticalAscentTimetothe surfacecalculatedat60FPM 18MPM fordepthsdeeperthan 60FT 18M and30FPM 9MPM fordepthsof60FT 18M andshallower DECO STOP ALT 1 Display informationprovidedinc...

Страница 94: ...trox MaxDepthwithiconsFT orM andMAX Press releasetheAbuttontoviewDECOSTOPALT3 ThedisplaywillreverttotheDECOSTOPMAINDisplay after3secondsunlesstheAbuttonispressed DECO STOP ALT 3 Display informationinc...

Страница 95: ...topDepth ThegraphicmessageDOWN DOWNwillscrollatthetopofthedisplayuntiltheAlarmisacknowledged silenced thenthemessageDOWN TO xxForxxMwillscroll IfyoudescendbelowtherequiredDecompressionCeilingbefore 5m...

Страница 96: ...iredStopDepth Thegraphic messageDOWN TO xxF orxxM willcontinuetoscroll ThisisacontinuationofaConditionalViolation NORM DELAYED VIOLATION 2 Fig 81 TheEliteT3cannotcalculateDecompressiontimesforStop Dep...

Страница 97: ...T 100M or399FT 120M whenoperatinginGAUG Mode theUPArrowwillflash andtheCurrentDepthandMax Depth onALT2 displayswillonlyindicate3dashes signifyingthatyouareOutofRange ThegraphicmessageTOO DEEPwillscrol...

Страница 98: ...onGaugeModeturnstheEliteT3intoadigital instrumentwithoutanydecompressionoroxygenmonitoring functions VIOLATION GAUGE DIVE MAIN DISPLAY Default informationprovidedincludes Fig 83 MessageUP VIOL scrolli...

Страница 99: ...eaturesandfunctions ThisconditionisaPermanentViolation andintheeventthata diveismadeduringthe24hourperiod afull24hoursurface intervalmustthenbeservedbeforeallfunctionsarerestored VIOLATION GAUGE SURF...

Страница 100: ...croll IfPO2continuestoincrease thevaluedisplayedwillincreasein incrementsof 01ATAtoamaximumvalueof5 00ATA WhenPO2reachesthePO2AlarmSetPoint theredLED warninglightwillflashandtheAudibleAlarmwillsoundag...

Страница 101: ...ning becomes0 00 hr min thegraphicO2appearsandthefullO2 BarGraphandUPArrowwillbedisplayedflashing Fig 86 TheredLEDwarningwillflash theAudibleAlarmwillsound andthemessageHIGH O2willscrollatthetopofthed...

Страница 102: ...hO2alarm TOO DEEP Depthalarm UP VIOL DecoStopgreaterthan70FT 21M required SLOW SLOW AscentRateTooFastalarm LOW AIR TIME AirTimeRemainingalarm lessthan5minutes LOW DIVE TIME DiveTimeRemainingalarm NDC...

Страница 103: ...CK WARNING Prior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommend...

Страница 104: ...e Check or when operating in GAUG Mode Every dive begins with GAS 1 10 minutes after surfacing from a multiple gas dive the Elite T3 s operation defaults to the GAS 1 FO2 AccesstoNORMDIVEGasSwitchings...

Страница 105: ...isbeingdisplayed These areaccessedfromtheTMT2 3USEscreen DepressingtheMbuttonfor2secondswhileviewinga NORMDIVEMAINscreenwillaccesstheTMT2 3USE Lead in screendisplayingtheSetPointSELF Fig 88 If bud isd...

Страница 106: ...uttonmomentarily 2seconds to accesstheGAS2SwitchPreviewDisplayfor10seconds GAS 2 SWITCH PREVIEW informationincludes Fig 90 GraphicGAS2 NIBG representingNitrogenLoading VARI ifascending O2BG ifany FO2S...

Страница 107: ...Press releasetheMbuttonmomentarily 2seconds to stepthroughtheGasSwitchPreviewscreensandaccess theGAS1SwitchPreviewscreen DepresstheMbuttonfor2secondswhiletheGAS1Switch Previewscreenisdisplayedtoswitch...

Страница 108: ...accesstheGAS1SwitchPreviewDisplay TO SWITCH FO2 FROM GAS 2 TO GAS 3 DepressingtheMbuttonfor2secondswhileviewingthe GAS3SwitchPreviewDisplaywillSwitchtheEliteT3 s FO2fromGAS2toGAS3andtheEliteT3 sRecei...

Страница 109: ...yPressureCheckscreensduringdivescanonly beaccomplishedduringthetimethataNORMDIVEMAIN screenisbeingdisplayedandcannotbeperformedwhile viewingAlternatedisplaysorduringthetimethatanAlarmis sounding BUDDY...

Страница 110: ...vert to the NORM DIVE MAIN Display After5seconds orlessifBUD1 s TMT2 s signalis acquired theBUD1screenwillappeardisplayingthe graphicBUD1andBUD1 sPressure Fig 95 orthe graphicNotAvAil NotAvailable for...

Страница 111: ...eTMTStatusCheckscreenswhilethe NORMSURFMAINscreenisbeingdisplayed DepressingandholdingtheSbuttonfor2secondswill activatetheEliteT3 sReceiverandaccesstheTMTStatus screensandPressuresoftheTanksreporting...

Страница 112: ...3 sec Switches from Gas 2 TMT 2 to Gas 3 TMT 3 after 3 sec Switches from Gas 3 TMT 3 to Gas 1 TMT 1 after 3 sec Back to NORM DIVE MAIN BUD1 PRESSURE BUD2 PRESSURE 3 sec TMT 2 3 USE Set for SELF TMT 2...

Страница 113: ...rior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as we...

Страница 114: ...MalternatingwiththeAltitudeLevelgraphic SEA orLEV2throughLEV13 andWET iftheunitiswet BatteryiconifanEliteT3LowBatteryWarningCondition exists flashingifTooLow NIBG representingNitrogenloading O2BG ifaN...

Страница 115: ...viewthatdive sLOGduringtheTransitionPeriod PressandreleasetheAbutton2times 2secondseach whileviewingtheNORMSURFMAINdisplaytoaccessthe LOGPreviewscreen Fig 99 PresstheSbutton toviewtheLOG1screen Nitrog...

Страница 116: ...artGloBacklight presstheSbutton ToaccessSURFALT PLAN FLY etc press releasetheAbuttonasrequired NORMSURFMAIN GAUGSURFMAIN FREESURFMAIN NORMSURFMAIN ALT PLAN FLY SAT LOG HIST ThePlanningSequencenowdispl...

Страница 117: ...rior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as we...

Страница 118: ...URFMAIN GAUG SURF MAIN Display Default informationprovidedincludes Fig 100 GraphicGAUGalternatingwiththeAltitudeLevelgraphic SEA orLEV2throughLEV13 andWET iftheunitiswet BatteryiconifanEliteT3LowBatte...

Страница 119: ...24 hours after surfacing before the Elite T3 resets and will operate in NORM Mode Air or Nitrox or FREE Dive Mode GAUG DIVE MAIN Display Default informationprovidedincludes Fig 101 GraphicGAUG TankPre...

Страница 120: ...ALT2 ThedisplaywillreverttotheGAUGDIVEMAINDisplay after3secondsunlessAispressed GAUG DIVE ALT 2 Display informationprovidedincludes Fig 103 GraphicTMT1 or2or3 TankPressurewiththePSI orBAR icon ifTMT1i...

Страница 121: ...Prior to diving with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as...

Страница 122: ...ndtheycannotbesilenced ToaccessFREEOperatingModewhileNORMGAUG MAINisdisplayed depresstheMbuttonfor2seconds NORMSURF GAUGSURF FREESURFMAIN FREE SURF MAIN DISPLAY informationincludes Fig 104 GraphicFREE...

Страница 123: ...wnTimer STATUSscreen allowingyouto Set Start StoptheTimer DepresstheAandSbuttonssimultaneouslyfor2secondsto accesstheSETFREEEDT ElapsedDiveTime ALARM DisplayfromwhichyoucanthenaccesstheSETFREE DEPTHAL...

Страница 124: ...REEMODE PresstheSbuttontoactivatetheBacklight ThedisplaywillreverttotheFREESURFMAINscreenafter3 seconds FREE MODE COUNTDOWN TIMER CDT DepressingtheAbuttonfor2secondswhileviewingtheFREE SURFMAINscreenw...

Страница 125: ...2secondswhileviewingtheCD TimerStatusscreenwhentheCDTimerisOFFwillaccesstheSETCDTIMERscreen withtheMINUTESetPointflashing NOTES Once the CD TIMER has been Set and Started by selecting ON it will conti...

Страница 126: ...withtheSetPointflashing DepressingandholdingtheSbuttonwhiletheSECONDS SetPointisflashingwillscrollthroughtheSetPointsata rateof4persecondfrom 00to 59in1Second 01 increments PressingandreleasingtheAbut...

Страница 127: ...int flashing NOTE The FREE EDT Alarm can only be Set turned OFF or ON while on the Surface and can not be changed during a Dive SET FREE EDT ALARM Display informationincludes Fig 110 GraphicEDT SetPoi...

Страница 128: ...rt beepswillsound3timesandthemessageDPTHwillbedis played3times PressingtheAbuttonmomentarily 2seconds whilethe SETFREEEDTALARMscreenisdisplayedwillaccessSET FREEDEPTHALARM1withtheSetPointflashing Sequ...

Страница 129: ...roughtheSet Pointsfrom30to330FT 10to100M inincrementsof 10FT 1M atarateof1SetPointperpressofthebutton PressingandholdingtheSbuttonwillscrollthroughtheSet Pointsatarateof4SetPointsperseconduntilrelease...

Страница 130: ...ementsof 10FT 1M atarateof1SetPointperpressofthebutton PressingandholdingtheSbuttonwillscrollthroughtheSet Pointsatarateof4SetPointsperseconduntilreleased PressingtheAbuttonmomentarily 2seconds willac...

Страница 131: ...2to100M inincrementsof 10FT 1M atarateof1SetPointperpressofthebutton PressingandholdingtheSbuttonwillscrollthroughtheSet Pointsatarateof4SetPointsperseconduntilreleased PressingtheAbuttonmomentarily 2...

Страница 132: ...ndsymbolFT orM PressandreleasetheAbuttonmomentarily 2seconds to accesstheFREEDIVEALTscreenfor3seconds DepresstheAbuttonfor2secondstoaccesstheFREECDT CountDownTimer STATUSscreen PresstheSbuttontoactiva...

Страница 133: ...oONwillStarttheCDTIMER indicatedbythecolonflashing Fig 117 PressingtheSbuttonwillactivatetheSmartGloBacklight PressingandreleasingtheAbuttonmomentarily 2 seconds willreverttotheFREEDIVEMAINscreen Ifno...

Страница 134: ...g 118 then reverttotheMessageFREE FREEDIVEDEPTHALARM S WhenDepthreachestheFREEDEPTHALARM1SetPoint 3 shortbeepswillsound3times theredLEDwillflash andthe MessageDPTHwillappearonthedisplay3timesmomentari...

Страница 135: ...vinginFREEDIVEMode nitrogenaccumulationfrom theFREEDivesinthatsetandanypreviousNORMDivescon ductedwithin24hoursisdisplayedastheNIBG WhenNitrogenLoadingincreasestotheCautionlevelindicated by7segmentsdi...

Страница 136: ...ill alternatelybeOn Offfor10minutesafterthedive Uponsurfacing theUPArrowwillberemoved however theFull NIBGandO2BGwillcontinuetoflashfor24hours Fig 123 OperationwillbeasPermanentViolationModeandnotacce...

Страница 137: ...with the Elite T3 you must also read and understand the AERIS Dive Computer Safety and Reference Manual Doc No 12 7203 which provides Important Warnings and Safety Recommendations as well as general p...

Страница 138: ...surfaceintervaltime maximumdepth elapseddivetime startdate starttime lowesttemperatureunderwater samplingrate diveprofile EliteT3 s setpoints pressure AirTimeRemaining OTU OTS ascentrate NIBG O2BG and...

Страница 139: ...orXP SuperVGAcardorcompatiblevideographicsadaptor 256colororgreater witha minimum800X600pixelscreenareaofdisplaysettings 16MBofavailableRAM 20MBofavailableharddrivestorage Mouse CDRomdrive Printer opt...

Страница 140: ...SoakandrinsetheRegulator s withtheTransmitter s attached Todissolvesaltcrystals uselukewarmwateror aslightly acidicbath 50 whitevinegar 50 freshwater After removalfromthebath placetheEliteT3andthe Reg...

Страница 141: ...ll beerasedduringfactoryservice Packageitusingaprotectivecushioningmaterial Includealegiblenotestatingthespecificreasonforreturn yourname address daytimephonenumber serialnumber s andacopyofyourorigin...

Страница 142: ...topreventformationofmoistureintheBattery Compartment s itisrecommendedthattheBattery s bechangedinanenvironment equivalenttothelocaloutdoortemperatureandhumidity e g donotchangethe Battery s inanairco...

Страница 143: ...holes in the Ring Fig 126 LifttheHatchRingupandawayfromtheHousing RemovetheclearBatteryHatch Elite T3 Battery Removal RemovetheRetainingBarlocatedacrossthelowerportionof theBattery Fig 127a Removethe...

Страница 144: ...pairpropersealing InspecttheButtons Lens andHousing s toensuretheyare notcrackedordamaged WARNING If damage or corrosion is found return your Elite T3 system to an Authorized AERIS Dealer and DO NOT a...

Страница 145: ...rblowdrywithahairdryersetatnoheat Elite T3 Battery Installation Slideanew3volttypeCR2450LithiumBattery negative sidedownintothe BatteryCavity Slideitinfromtherightsideandensurethatitslidesunderthecont...

Страница 146: ...clockwise5de greesuntilthetabsengage thentightenit5moredegrees byturningitcounterclockwisewiththeaideofasmallblade screwdriverorspannertool pressingagainsttheupper left armoftheRing Fig 130 Transmitte...

Страница 147: ...ushwith theoutersurfaceoftheHousing Fig 133 Elite T3 System Testing PressurizetheRegulatorAssembly andTransmitter ActivatetheEliteT3andwatchcarefullyasitperformsafull diagnosticandbatterycheck andente...

Страница 148: ...he Regulator sHPPort Fig 134 andtightenuntilsecurewith a5 8 open endwrench AttachtheRegulatorFirstStagetoafullScubaTankand pressurizebyslowlyopeningtheTankValve listeningfor anyindicationofairleakinga...

Страница 149: ...e currentALTITUDE TheMathematicalModelintheEliteT3accountsforthereducedNoDecompressiondive TimeavailablebasedonNationalOceanicandAtmosphericAdministration NOAA guidelines Whendivinginhighaltitudewater...

Страница 150: ...0 58 0 55 0 52 0 48 0 45 0 43 0 41 0 39 0 37 60 0 57 0 46 0 43 0 40 0 38 0 36 0 34 0 33 0 31 0 30 0 29 0 28 0 27 70 0 40 0 33 0 31 0 30 0 28 0 27 0 26 0 24 0 23 0 22 0 20 0 19 0 18 80 0 30 0 26 0 24...

Страница 151: ...9 0 09 0 08 33 0 17 0 14 0 12 0 11 0 11 0 10 0 09 0 09 0 08 0 08 0 08 0 07 0 07 36 0 14 0 11 0 10 0 09 0 09 0 08 0 08 0 07 0 07 0 07 0 06 0 06 0 06 39 0 11 0 09 0 08 0 08 0 07 0 07 0 07 0 06 0 06 0 06...

Страница 152: ...d Oxygen Exposure Limits Based on NOAA tables TRANSMITTERS Battery and Pressure check every 2 minutes when asleep every 2 seconds when awake Startup Pressure equal or greater than 120 PSI 8 BAR Batter...

Страница 153: ...1000 to 3000 PSI 70 to 205 BAR Off End Press Alarm 300 to 1500 PSI 20 to 105 BAR 300 PSI Max PO2 Alarm 1 20 to 1 60 ATA 1 60 ATA Set U Group Utilities Wet Activation On Off On Units of Measure Imperia...

Страница 154: ...re Stop Depth Stop Time Dive Time Remaining Current Depth NORM Decompression Dive Displays Main default NIBG O2BG VARI Stop Depth Pressure Stop Time Total Ascent Time Current Depth Alternate 1 Day of...

Страница 155: ...ximum Depth 330 399 FT 100 120 M 1 FT 1 M Gas 1 FO2 Set Point Air 21 to 50 1 Gas 2 FO2 Set Point Air 21 to 100 1 Gas 2 FO2 Set Point Air 21 to 100 1 PO2 Value 0 00 to 5 00 ATA 01 ATA Dive Time Remaini...

Страница 156: ...Countdown Timer 23 50 to 0 00 hr min after violation BAR GRAPHS Nitrogen Loading Bar Graph segments No Decompression zone 1 to 7 Decompression zone 8 all Oxygen O2 Bar Graph segments Normal zone 1 to...

Страница 157: ...pon activation by push button and every 15 minutes while in NORM GAUG FREE Surface Modes Does not measure ambient pressure when Wet Compensates for Altitudes above sea level beginning at 2 000 feet 61...

Страница 158: ...age Cannot be manually activated deeper than 4 FT 1 2 M if Water Activation is set OFF Cannot operate at elevations higher than 14 000 feet 4 270 meters Operating Temperature Out of the water between...

Страница 159: ...r _________________________________ Transmitter 2SerialNumber _________________________________ Transmitter 3SerialNumber _________________________________ DateofPurchase ____________ Purchasedfrom __...

Страница 160: ...Doc No 12 7201 r01 2 14 06 2002 Design 2006 AERIS 2002 Davis Street San Leandro CA 94577 Tel 510 346 0010 Fax 510 346 0015 Web site http www diveaeris com E mail info2 diveaeris com...

Отзывы: