AERF WIRELESSBAND 1.0 Скачать руководство пользователя страница 2

PROGRAMMING PROCESS 

RECEIVER  OPTION SELECTOR 

TERMINAL CONNECTIONS 

TRANSMITTER 

RECEIVER 

 Important: 

- To replace transmitter battery and safety of the power supply insert battery 1 first and then battery 2! Unless this order is observed, correct 
function is not guaranteed. Batteries must be suitable for use at temperatures of -20°C and above. 

- System has no fuse protection. It is advisable to include a fuse protection of minimum 100mA and maximum 250mA into the external power.

CODE MEMORIZATION

-

Press button PROG button for 1,5 sec. 

-

On hearing the acoustic signal stop pressing as the receiver will be logged into the memorizing code process 

-

From this moment received transmitters will be memorized.

-

In order to memorize push PROG button on the transmitter. 

-

The memorization of a code is acknowlegde with one acoustic signal.

-

The receiver will exit from memorization code process automatically after 10 seconds from the last transmitter input. This will be indicated    

  

with two acoustic signals. 

MEMORY RESET

-

Press PROG button for 3,5 seconds.

-

After 1,5 seconds one acoustic signal will be heard indicating that you have entered the code memorization mode, maintain the button      

       pressed. 
-

After 3,5 seconds you will hear several acoustic signals for 10 secs.

-

Stop pressing the button. 

-

The WirelessBand will have reset all transmitters.

-

The System remains in memorization process, ready to receive new transmitters 

MEMORY FULL INDICATOR

In case of full memory you will hear several acoustic signals for 10 seconds upon trying to memorize a new transmitter.

LOW BATTERY INDICATOR

Low battery indication consists on 4 acoustic sounds each time a message is received from a programmed transmitter. Both, warning LED and buzzer are 
set on simultaneously. 

OPTION 1 - CLASS 2   

ON

Class 2 enabled. Standard setting for safety operation. 

OFF

Class 2 disabled

OPTION 2 - TRANSMITTER FRECUENCY

ON

Frequency 869,85 MHz

OFF

Frequency 868,95 MHz

OPTION 3 - RECEIVER TEST TYPE 

ON

Normally Open contact

OFF

Normally Close contact

OPTION 4 - AUTOMATIC FRECUENCY AGILITY

ON

Automatic frequency Agility enabled

OFF

Automatic frequency Agility disabled

CLASS 2:

- It is very important that the selected frequency coincides with the 
  transmitter. Otherwise the system will not work.
- With class 2 Disabled the current consumption is less. this is the 
  perfect setting for storing the product (5uA class 2 disabled to 15uA 
  class 2 enabled).
- Every 5 seconds there is a transmission. 
- If no signal is received during 15 seconds, receiver relays goes to 
  security  
- Receiver test only checks the relay.
- Receiver will not work until all programmed transmitters are identified.

GENERAL (RECEIVER) 

- Installation, startup, modification and retrofitting of the system may only be carried out by an electrician.
- Switch off the operating voltage before working on the system.
- The control unit may only be used to protect against dangers at crushing and shearing points on automatic sliding gates 
(designated  Use). Any other use is prohibited.

WARNING!!

RESISTIVE

SAFETY

EDGE

 1   2  3

8K2

INHIBITOR

 1   2  3   4  5   6  7 

12/24V 
AC/DC

OUTPUT 
NC   NO

RELAY 

TEST

8K2

Instruction Manual

GB

( WIRELESSBAND 1.0 )