TECHNICAL AND MAINTENANCE DOCUMENTATION 

HAT

www.aereco.com

The fans are intended for mechanical exhaust ventilation in residential buildings. They are 

the basis for the entire ventilation installation, which includes a duct network, fire dampers, 

exhaust grilles, diffusers and other components. 

Unlike standard fans, the working specifications of HAT are adapted for compatibility with 

HIGRO

®

 systems. 

HD automation 

Integrated into the HAT fan, the HIGROdynamic automated system adapts the fan speed 

to the opening degree of the HIGRO

® 

AERECO diffusers and grilles. This means that the 

electronic system lowers the fan speed at low flow volumes, adapting to the lower airflow 

resistance in the ducts, and increases the fan speed at higher airflow volumes caused by the 

open dampers of the hygroregulated grilles. The HIGROdynamic automated system prevents 

improper operation of the ventilation system, in particular excessive noise from grilles and 

diffusers at low humidity. The automated regulation of operating parameters reduces the 

fan's energy consumption.

In addition the HD/PD/MD automated system can be equipped with the day/night function - 

TS, which is activated by connecting an external control signal from the ACC.DN2 automated 

system. This allows for the fan speed to be lowered during the night hours.

In addition to the savings in electricity consumption, the automated control of fan 

performance enables better acoustic performance of the exhaust grilles and a reduction in 

the noise emitted by the fan.

In contrast to decentralized ventilation systems (a fan in each auxiliary room), the HIGRO

® 

systems enables the reduction of investment costs and minimises noise, as the fan which is 

the main source of noise is distant from the room and additionally silenced with the acoustic 

silencer SAS-1200. The fans are intended for pressing clean ventilation air free of dust, 

corrosive substances and explosive mixtures. Using the fan for purposes other than intended 

voids the warranty.

1.  GENERAL INFORMATION

600��� mm

1500��� mm

ATTENTION!!! 

The compact design minimises 

the necessary installation 

space on the roof. The fans, 

thanks to their flexible work 

and adaptation to the network 

parameters, can be used both 

in tall and short buildings. 

Содержание HAT-100-B

Страница 1: ...HAT FANS FOR MEDIUM PRESSURE AERECO VENTILATION SYSTEMS TECHNICAL AND MAINTENANCE DOCUMENTATION HAT HD ...

Страница 2: ......

Страница 3: ...TABLE OF CONTENTS 1 General information 2 Fan installation 3 Fan models 4 Electrical specifications and connections 5 Start up 6 Use 7 Transport and storage ...

Страница 4: ...ers reduces the fan s energy consumption In addition the HD PD MD automated system can be equipped with the day night function TS which is activated by connecting an external control signal from the ACC DN2 automated system This allows for the fan speed to be lowered during the night hours In addition to the savings in electricity consumption the automated control of fan performance enables better...

Страница 5: ...er the power supply has been disconnected The installer is responsible for the compliance with all applicable safety regulations for electrical connections and protection against accidental contact Clearance must be provided around the fan the automated system and the measuring stub to allow for future maintenance The automated control system must be located in an easily accessible place During in...

Страница 6: ...z 1 7 170 HAT 160 C 230 VAC 50Hz 1 7 170 HAT 200 C 230 VAC 50Hz 1 7 170 HAT 250 C 230 VAC 50Hz 1 7 170 HAT 250 D 230 VAC 50Hz 1 75 170 Connecting the HD automated system The power supply for the fan with a HD automated system should be connected as shown in the drawing BN BU YG Y G Y G B U B U B U B U B N B N B N B N Y G YG Y G Y G Y G Y G B N BN BN BN BN BN B U BU BU BU BU BU BU BU B N B N B N B ...

Страница 7: ... To open the housing of HD automated unit use a screwdriver Do not use a power screw driver because of the danger of damaging the screws and loss of tightness of the casing 1 PG11 cable gland enables connection of 1x230 V power supply The power wires should be connected to the corresponding terminal blocks 2 in accordance with point 4 of the technical and propulsion documentation The potentiometer...

Страница 8: ...thout risk of breaking or fraying due to vibrations the protective earthing conductor and possibly also the equipotential bonding con ductor are correctly connected to the fan and to the grounding point busbar safety devices have been installed and they comply with the general safety regulations and the requirements of section 4 of the documentation the voltage supply corresponds to the rated valu...

Страница 9: ... the weights balancing the impeller are in place and the impeller is not deformed After cleaning make sure that the fan works without any abnormal noises Check that the impeller is not jammed and that the motor protection is not loosened HAT fans are factory packed in appropriate cardboard boxes It is recommended to leave the fans in their original packaging during the whole transport to the place...

Страница 10: ...NOTES ...

Страница 11: ...B 125 1B 160 1B 160 1C 200 1C 250 1C 250 1D 100 3B 125 3B 160 3B 160 3C 200 3C 250 3C 250 3D 3 We declare the conformity of the product with the following directives standards and documents Directive 2014 30 EU Directive 2014 35 EU Directive 2006 42 EC European Commission Regulation 1253 2014 Łomna Las 01 April 2020 Marcin Gasiński Technical and Energy Requirements Specialist ...

Страница 12: ...AERECO S A 62 rue de Lamirault Collégien 77615 MARNE LA VALLEE CEDEX 3 FRANCE www aereco com FLY728_v1_NOT_INST_HAT HD ...

Отзывы: