1.1. WARNINGS

PLEASE READ THE FOLLOWING INSTRUCTIONS BEFORE THE 

INSTALLATION:

In case of non-compliance with advice and warnings contained 

in this manual, the manufacturer can not be considered 

responsible for damages to persons or property.

The manual describes how to install, use and maintain correctly 

the appliance. The only way to ensure the efficiency and longevity 

of the product is to comply with these requirements.

Do not use this appliance for any applications for which it is not 

intended.

The system must be installed by experienced contractors, trained 

in the specificities of the process and having the necessary skills 

in aeraulics and electricity.

The use of gloves to carry on the installation is recommended.

After unpacking the appliance, make sure it is not damaged. Any 

functional default must be reported to your reseller.

The use of an electrical appliance implies the following 

fundamental rules:

 ·

Do not touch the appliance with a wet or damp body (hands, 

feet, etc.).

 ·

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance 

by a person responsible for their safety. To avoid any risk, do not 

allow them to play with the appliance.

 ·

The electrical installation and electrical connections must 

be carried out by a qualified technician according to the 

manufacturer’s instructions and in compliance with the 

characteristics listed on the nameplate of the unit.

 ·

Before carrying out any operation on the appliance, unplug or 

disconnect it from the power supply, and ensure it can not be 

accidentally restored.

 ·

Power cable modification or replacement must only be carried 

out by qualified personnel or by After-sales Service in order to 

avoid any accident.

 ·

Children being supervised not to play with appliance.

1. 

INTRODUCTION

This document presents the installation and maintenance schemes 

for Occupancy sensor with Hub 8 SE: exhaust compensation valve 

and third-party Modbus system. First, we will focus on the S-PRE/

DAY-NIGHT/T Modbus sensor's connections with Hub 8 SE and 

secondly with third party Modbus systems.

2. 

DESCRIPTION 

2.1. GENERAL INFORMATION

Protocol:

 Modbus RTU / through RS485

Baud rate:

 9600 bit/s

Modbus implementation class:

 basic

Connectors type:

 RJ45 with shielded CAT5E cable or better

 
The detection principle of the S-PRE/Day*-Night**/T Modbus sensor is 
based on infrared rays absorption. This method allows a very high fidelity 
of response and is independent of any other variable (such as moisture, 
dust, etc.).

The connection to the system is made through RJ45 connectors.

The S-PRE/DAY*-NIGHT**/T optical sensor is composed of: 

- A Fresnel lens with 31 pairs of facets that concentrate the radiation 
emitted by a person on pyroelectric sensors and cut the detection field 
into 62 zones

- Specific pyroelectric sensors that collect radiation infrared emitted by a 
person and detects mouvements through the factes of the Fresnel lens 
the number of movements through the facets of the Fresnel lens

The detector includes a Red LED indicator that displays the detections in 
order to inform the users. When luminosity in the room is very low, the 
LED is automatically switched off. 

COVERAGE PATTERN

Side view

Top view

2,7 m

100°

6 m

Walking direction

Содержание CAP1669

Страница 1: ...INSTALLATION AND MAINTENANCE INSTRUCTION ENGLISH VERSION S PRE DAY NIGHT T MODBUS SENSOR HUB 8 SE ACCESSORIES THIRD PARTY MODBUS SYSTEM TF6582_A_NOT_INST_PRE_SENSOR_MODBUS Aereco S A ...

Страница 2: ...ate of the unit Before carrying out any operation on the appliance unplug or disconnect it from the power supply and ensure it can not be accidentally restored Power cable modification or replacement must only be carried out by qualified personnel or by After sales Service in order to avoid any accident Children being supervised not to play with appliance 1 INTRODUCTION This document presents the ...

Страница 3: ...ped with claws for installation in false ceiling Location of sensors ceiling positioning in a detection zone zone located at least at 1 meter from walls considered as zone where there are few movements height installation ceiling position up to 3 5 meters 3 5 m max 3 m min 4 2 m max 1 m 2 m 3 6 m 2 m 2 8 m max 2 8 m max Dead zone Day detection of the presence of light naturel light or artificial l...

Страница 4: ...her one The index numbers must be incremented to each other so that there is no digit jump Example Presence sensor bedroom A 1 because Hub SE outlet n 1 is connected to bedroom A Presence sensor bedroom B 2 because Hub SE outlet n 2 is connected to bedroom B Presence sensor bedroom C 3 because Hub SE outlet n 3 is connected to bedroom C CO2 sensor in living room 4 because Hub SE outlet n 4 is conn...

Страница 5: ...e Hub SE cannot be started accidentally The Hub SE communicates to the other components through ModBus connection All the components are linked other via a daisy chain At the beginning and at the end of the daisy chain a termination is needed B B B C D D A 230 VAC Modbus connection to the occupancy sensor A Hub SE B Sensors C Compensation valve at exhaust D ModBus Termination RJ 45 Supply 230 V 1 ...

Страница 6: ...onnection schemes Aereco offers an optimal solution of electrical control board ref ADX1785EX that is adapted to its prsence Modbus sensors Modbus connection to the occupancy sensor 2W Modbus on RJ45 socket pin out 6 THE S PRE DAY NIGHT T SENSOR S CONNECTIONS WITH THIRD PARTY MODBUS SYSTEM 6 1 SETTINGS OF THE S PRE DAY NIGHT T SENSOR FOR THIRD PARTY MODBUS SYSTEM 15 indexation positions are allowe...

Страница 7: ...r Cut and free the wires coming from the RJ45 connector and connect directly to the terminal block of the controller Second possibility is to use an adaptor RJ45 RJ45 to terminal block 6 4 APPLICATION DEVELOPMENT FOR MODBUS SENSOR Th diagram below shows the connexion between the Computer and sensors Note Aereco developed a customised kit for connecting PC and sensors you can easily order with the ...

Страница 8: ...se Time 1fc ms typ 500ms Built in temperature sensor1 Temperature working range 2 C to 50 C Accuracy 0 5 C ensured at 25 C Conversion Gain 10mV C LED Indicators Yellow LED for Modbus traffic indicator Red LED for presence indicator Electrical specifications Power supply 12 VDC Power consumption standby mode 2mA Max Power consumption detection mode 3mA Max Connection Type 2xRJ45 shielded Operating ...

Страница 9: ...fter sales service In any case the warranty may not cover additional costs of labour transport or compensation of any kind The warranty does not cover damage due to improper installation in this manual improper use or attempted repair by unauthorized personnel In case of problems please contact your installer or your reseller 9 CONFORMITY AND STANDARD The S PRE DAY NIGHT T Modbus sensor is CE cert...

Страница 10: ...SOR_MODBUS Copyright Aereco All data and pictures in this document are non contractual and are subject to change without prior notice Aereco S A 62 rue de Lamirault Collégien 77615 MARNE LA VALLEE CEDEX 3 FRANCE www aereco com ...