background image

 

 

- 9 - 

the alarm on or off (if the alarm is enabled, the speaker icon on the LCD will be turned on indicating 
the  alarm  function  has  been  enabled).  Press  the 

SET

  key  to  confirm  the  setting  and  continue 

pressing  the 

SET

  key  to  toggle  through  each  alarm  mode  until  it  returns  to  the  normal  display 

mode. 

 

  Press  the 

SNOOZE/LIGHT

  key  or  no  keys  for  10  seconds  at  any  time  and  the  alarm  mode  will 

return to Normal Mode 

 
Canceling the Temperature Alarm While Sounding 

When a set weather alarm condition has  been triggered that particular alarm will sound for 120 seconds 
and flash until the weather condition does not meet the alarm level. Press any key to mute the alarm. When 
the weather alarm condition is activated again within 10 minutes the alarm will not sound but will continue 
to  flash  until  the  weather  conditions  have  become  more  stable.  This  feature  is  useful  to  avoid  repeated 
triggering for the same alarm value.     

 
Note: 

The alarm will reactivate automatically once the value has fallen below the set value. 

 

The outdoor weather alarm   

When  a  set  outdoor  weather  alarm  has  been  triggered  it  will  flash  on  the  LCD  display  and  the  general 
outdoor alarm icon and high/low alarm icon will flash accordingly. For example, in the outdoor temperature 
display mode,  when the  dew point high alarm is triggered the 

DEW  POINT

 icon  will flash  along  with the 

general outdoor alarm icon and high alarm icon, telling the user that the current alarm source is from the 
dew point.

 

 

 

 

 

5.4 Min/Max Mode 

 

  While in Normal Mode, press the 

MIN/MAX

 key to enter the Maximum Mode, the 

MAX

 logo and 

the general maximum record will be displayed. 

  Press the 

MIN/MAX

 key again to enter the  Minimum Mode, the 

MIN

 icon and minimum record 

will be displayed   

  Press the 

MIN/MAX

 key again to return to Normal Mode. 

  In the maximum reading mode, press the 

+

 key to display the following maximum values together 

with the  time  and  date  stamp  at which  these  values  were  recorded.

 

Pressing  the 

SET

  key  will 

reset the value to the current reading together with the current time and date.

 

   

1.  Indoor humidity maximum 
2.  Indoor temperature maximum 
3.  Outdoor humidity maximum 
4.  Outdoor temperature maximum   
5.  Outdoor dew point maximum 
6.  Pressure maximum 
 

 

In the minimum reading mode, press the 

+

 key to display the following minimum values together 

with the  time  and  date  stamp  at which  these  values  were  recorded.  Pressing  the 

SET

  key  will 

reset the value to the current reading together with the current time and date.

   

1.    Indoor humidity minimum 
2.    Indoor temperature minimum 
3.    Outdoor humidity minimum 
4.    Outdoor temperature minimum   

Содержание WS1173

Страница 1: ...4 4 Examples of changing weather icons 6 4 5 Storm warning indicator 6 5 Program modes 6 5 1 Quick display mode 6 5 2 Setting mode 7 5 2 1 Setting Calibrated Humidity 8 5 2 2 Setting Barometric Pressure 8 5 3 Alarm mode 9 5 4 Min Max mode 9 6 Trouble Shooting 10 7 Specifications 10 8 Contact Information 11 This Operation Manual is part of this product and should be kept in a safe place for future ...

Страница 2: ... our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA As many issues can be a result of incorrect setup please contact our local distributor Monax Test Weather www monaxtestandweather com au ...

Страница 3: ...cation Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronised with the base station to receive weather data Thus if the batteries have been changed on the transmitter then the receiver must be powered up again to re learn the transmitter code After the remote sensor is powered up the sensor will tr...

Страница 4: ...s Never dispose of batteries in a fire as this may cause an explosion risk of fire or leakage of dangerous chemicals and fumes 3 2 Mounting 1 Base station With one foldable leg at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by the hanging holes also at the back of the unit It is important to check that outdoor sensor data can be...

Страница 5: ...ature display unit 12 Indoor temperature and humidity alarm on indicator 13 Remote sensor transmit signal indicator 14 MIN MAX information 15 Dew point temperature display 16 Outdoor humidity display 17 Outdoor temperature and humidity low alarm and high alarm 18 Temperature display unit 19 Outdoor temperature display 20 General outdoor alarm icon 21 Weather forecast icon 22 Weather tendency indic...

Страница 6: ... period the weather conditions have become stable the arrows will fix indicating a stable condition 4 4 Examples of changing weather icons 4 5 Storm warning indicator The storm threshold can be set to suit the user s requirements for storm forecasting anywhere from 5 9hPa default 4hPa When there is a fall below the pressure threshold within any given 3 hour period the clouds with rain icon as well...

Страница 7: ...elative pressure setting from 919 0hPa 1080 0hPa default 1013 5hPa 10 Pressure threshold setting default 2hPa 11 Storm threshold setting default 4hPa In the setting mode press the key or MIN MAX key to change or scroll the value Holding the key or MIN MAX key for 3 seconds will increase decrease the digits faster Press the SNOOZE LIGHT key or no keys for 10 seconds the setting mode will return to ...

Страница 8: ...evel corrected pressure the pressure your location would be at if located at sea level is generally higher than your measured pressure To determine the relative pressure for your location locate an official reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reportin...

Страница 9: ... flash accordingly For example in the outdoor temperature display mode when the dew point high alarm is triggered the DEW POINT icon will flash along with the general outdoor alarm icon and high alarm icon telling the user that the current alarm source is from the dew point 5 4 Min Max Mode While in Normal Mode press the MIN MAX key to enter the Maximum Mode the MAX logo and the general maximum re...

Страница 10: ... reinsert the batteries and wait for a few minutes to see whether the signal is picked up Check for sources of interference cordless phones baby monitors PC monitors etc If this is an issue the console and or transmitter will need to be relocated If none of these is causing the problem you may have a faulty transmitter 7 Specifications Outdoor data Transmission distance in open field 100meter max ...

Страница 11: ... parts sent quickly if needed Purchased in NEW ZEALAND Please contact our local distributor Scientific Sales www scientificsales co nz and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed For all others please contact the retailer who sold you this item EU DECLARATION OF CONFORMITY Here...

Отзывы: