- Make sure that equipment is firmly seated before lifting it. 

Risk of injury! Watch out for nails when disassembling the timber frame! 

Warning! Risk of personal injury and equipment damage! 

Due to a high center of gravity, some equipment can tend to tip over and cause damage to persons and property. 

- When transporting the unit, carefully observe its behavior and do not get near any possible hazardous areas. 

 

1.6 Intended use 

AZURE WHEEL 25 device is designed to correspond the need of 2500 m

3

/ h air flow. There is a ePM1 55% class filter on the 

fresh air side and a ePM10 50% class filter on the exhaust side as standard. The units are produced according to European Union 

energy criteria. 

AZURE WHEEL devices are designed with high energy efficient, low sound pressure and low power consumption plug fans. Plug 

fans with EC motors can be driven with 3 fixed speeds or steplessly with the help of an air quality sensor thanks to build in smart 

control system. 

 

The AZURE WHEEL units are equipped with rotary heat exchangers. Through this procedure more than 80 % of the extract air 

heat is transferred to the external air. The supply air is led by the duct system to the primary (supply air needing) areas. The used 

air is extracted from the secondary areas (like e.g. social rooms, toilets, showers etc.). It flows back through the ducting to the 

ventilation unit, transfers the heat and is discharged by the exhaust air duct to the atmosphere. 

 

The heat recovery efficiency depends on several factors, which include, among other things, air humidity and the temperature 

variation  of  outside  air  and  exhaust  air.  The  fan  performance  can  be  adjusted  by  the  controller  in  scope  of  delivery.  Various 

sensors e.g. CO

or humidity sensors (accessory) are available on request, with which automatic fan control is possible. 

 

    

Permissible operating air temperature and humidity is 0/40 °C and 95% RH for AZURE WHEEL units.

 

 

1.7 Performance data 

Mechanical  connections  must  be  made  correctly  in  order  to  obtain  maximum  efficiency  from  the  device.  The  device's  thermal 

efficiency, sound level and electrical performance may vary depending on the ambient conditions the device is operating. These 

conditions may affect the measurement result on site and vary from the catalogue data. 

 

1.8 Guideline series VDI 6022 

The  AERA  AZURE  WHEEL  ventilation  units  in  this  series  are  produced  compliant  with  VDI  6022.  The  guidelines  range  from 

operating  regulations  and  material  requirements  through  to  construction  regulations,  which  ensure  high  air  quality.  It  must  be 

ensured that only original AERA accessories are used for operation compliant with VDI 6022. 

 

1.9 Heat systems 

The simultaneous use of controlled ventilation (AZURE WHEEL) and heat systems which depend on room air (tile oven, gas stove 

etc.) requires compliance with all applicable regulations. 

 

The  use  of  heat  systems  which  depend  on  room  air  are  only  permitted  in  state-of-the-art  dense  apartments  with  separate 

combustion air supply; only  then are AZURE WHEEL and heat systems decoupled from each other and operable meeting the 

demands. 

 

The  relevant  applicable  regulations  on  the  combined  use  of  heat  systems,  domestic  ventilation  and  extractor  hoods  (Federal 

Association of Chimney Sweeps (ZIV)) must be observed! 

Содержание AZURE WHEEL

Страница 1: ...1 User s Manual AZURE WHEEL ROTARY HEAT RECOVERY VENTILATION ...

Страница 2: ...age 4 1 7 Performance data 1 8 Guideline series VDI 6022 1 9 Heat systems 1 10 Technical data 1 11 Disposal 1 12 Disassembly and re assembly CHAPTER 2 INSTALLATION 2 0 Assembly CHAPTER 3 FUNCTIONAL DESCRIPTION 3 0 Functional Description Page 4 Page 4 Page 4 Page 5 Page 5 Page 5 Page 5 Page 6 CHAPTER 4 DIMENSION PERFORMANCE CURVE 4 0 Dimensions Page 6 4 1 Performance Curve CHAPTER 5 WIRING DIAGRAM ...

Страница 3: ...n of liability If the preceding instructions are not observed all warranty claims and accommodation treatment are excluded This also applies to any liability claims extended to the manufacturer The use of accessories not offered or recommended by AERA is not permitted Potential damages are not covered by warranty 1 3 Regulations Guidelines If the product is installed correctly and used to its inte...

Страница 4: ...things air humidity and the temperature variation of outside air and exhaust air The fan performance can be adjusted by the controller in scope of delivery Various sensors e g CO2 or humidity sensors accessory are available on request with which automatic fan control is possible Permissible operating air temperature and humidity is 0 40 C and 95 RH for AZURE WHEEL units 1 7 Performance data Mechan...

Страница 5: ...damage Due to a high center of gravity some equipment can tend to tip over and cause damage to persons and property When transporting the unit carefully observe its behaviour and do not get near any possible hazardous areas 1 12 Disposal Before starting any operation please ensure that the product is isolated from its mains electrical supply in order to ensure that fans cannot be run Dispose of al...

Страница 6: ...he device 5 The assembly of the AZURE WHEEL compact unit must only take place in rooms that are free of frost as there is a danger of freezing The room temperature must not fall below 5 C 6 In order to prevent sound transmission appropriate acoustic decoupling must be provided on site depending on the building material CHAPTER 3 FUNCTIONAL DESCRIPTION 3 0 Unit Description Fig 4 1 Supply Fan 2 Exha...

Страница 7: ...1 1101 1284 350 410 55 1940 856 2044 1944 1814 1997 650 410 4 1 Performance curves 0 200 400 600 800 1000 1200 0 500 1000 1500 2000 2500 3000 Pressure Drop Pa Airflow m3 h AZURE WHEEL 25 0 200 400 600 800 1000 1200 1400 0 1000 2000 3000 4000 5000 6000 Pressure Drop Pa Airflow m3 h AZURE WHEEL 55 A B C D E F G H ...

Страница 8: ...8 CHAPTER 5 WIRING DIAGRAM Azure Wheel 25 ...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...12 Azure Wheel 55 ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ... performed by user other than cleaning and eye inspection Users should contact the AERA company for faults detected during operation or maintenance If you have problems and need to get a service please contact the following address FACTORY 3 Cadde No 13 Pancar OSB Torbalı İzmir TEL 90 232 799 0 111 FAKS 90 232 799 01 14 ...

Страница 17: ...TECH Sales Office VaryapMeridian Grand Tower A Blok No 89 Ataşehir İSTANBUL TEL 90 216 504 76 86 FAX 90 216 504 76 90 Factory 3 Cadde No 13 Pancar OSB Torbalı İzmir TEL 90 232 799 0 111 FAX 90 232 799 01 14 R D Center 10032 sokak No 2 1 B 210 Bilimpark ITOB Menderes İZMİR aera com tr ...

Отзывы: