1. MISCELLANEOUS 

1.1. General 

precautions 

The following measures of safety an precaution should be observed during every 

moment of operation and maintenance of this equipment. The erroneous handling or ignoring 
this instructions, could alter in a serious way the functioning and performance of the 
equipment. 

AEQ

 will not be liable to any injuries or damages incurred by an incorrect 

handling of the equipment. 

1.1.1.  Read all Instructions 

Before operating this equipment an connecting it to any external power source, it is 

absolutely necessary to thoroughly read all the instructions contained in this manual, and to 
do so in the established order. This way, you will get the best performance from your 
equipment from the very start, and at the same time, you will avoid any incorrect handling or 
operation that could result in damage to the same. 

1.1.2.  Power and Ground connection 

To reduce the electrical shock risk, the AM-03 must to be connected to ground. The 

unit is supplied with the ground plug connector. If necessary to change the plug, the ground 
wire is the yellow/green one. 

1.1.3.  Protection against voltage fluctuations 

On locations where power fluctuations are frequent, an external protection device is 

needed to guarantee that the voltage required for the unit is the appropriate one. 

1.1.4.  Water and humidity 

It is strongly recommended to not use the equipment on locations where there exist a 

risk of water penetrating in the interior of the equipment, i.e. rain, mist, wet floors, etc. Neither 
is it recommended to use the equipment on locations with an elevated level of atmospheric 
humidity, whereas this frequently is condensed inside the equipment.  

Содержание AM-03

Страница 1: ...AEQ AM 03 Self powered Stereo Audio Monitor USER S MANUAL ED 10 06 V 1 1 14 05 2014 ...

Страница 2: ...DIO INPUT CONNECTIONS 3 1 2 AUDIO OUTPUT CONNECTIONS 4 OPERATING INSTRUCTIONS 4 1 GENERAL 4 2 OPERATING THE EQUIPMENT 4 2 1 GAIN CONTROL 4 2 2 L R BALANCE SELECTOR 4 2 3 INPUT SELECTION 4 3 AUDIO PHASE METERING 4 3 1 GENERAL 4 3 2 LEFT CHANNEL SIGNAL 4 3 3 RIGHT CHANNEL SIGNAL 4 3 4 STEREO SIGNAL IN PHASE 4 3 5 MONOAURAL SIGNAL IN PHASE 4 3 6 STERIO SIGNAL OUT OF PHASE 4 3 7 MONOAURAL SIGNAL OUT O...

Страница 3: ...ent from the very start and at the same time you will avoid any incorrect handling or operation that could result in damage to the same 1 1 2 Power and Ground connection To reduce the electrical shock risk the AM 03 must to be connected to ground The unit is supplied with the ground plug connector If necessary to change the plug the ground wire is the yellow green one 1 1 3 Protection against volt...

Страница 4: ...t 1 1 6 Maintenance The maintenance operations of this units should be carried out exclusively by qualified technical service AEQ is not liable to any damage caused to the equipment due to any maintenance operation without our authorization neither to the damage that an equipment repaired without such authorization could inflict to other equipment or persons Be aware that this unit contains very h...

Страница 5: ...comply with these conditions will not be accepted 3 AEQ will at its own cost repair the faulty product once returned including the necessary labour to carry out such repair wherever the failure is caused by defects of the materials design or workmanship The repair will be carried out in any of the AEQ authorized Technical Service Center This guarantee does not include the freight charges of the pr...

Страница 6: ...can normative In some countries it could be necessary to replace this plug with one that complies with the local standards If this could be your case please replace the plug before operation 2 1 2 Equipment power on Once checked and modified following the instructions in Section 2 1 1 the equipment is ready to be connect to mains Before connecting it please turn the power switch to off fig 3 Now t...

Страница 7: ...tput 3 1 1 Audio input connections The six connections are numbered from 1 to 6 The left and right channels are labeled R and L respectively as well as the signal of each connector s pin V for the positive polarity V for the negative polarity and GND for the ground 3 1 2 Audio output connections The equipment has one stereo audio output in the back panel that uses three pin connectors to monitor t...

Страница 8: ...anel is able to detect any signal out of phase background noise etc All the controls are located on the front panel of the equipment Gain control Six stereo audio inputs selector Left or right channel and balance selector Headphones connector with automatic speaker disconnection Phase meter On Off switch with power led indicator The AM 03 provides innovative solutions to multiple audio monitoring ...

Страница 9: ...ted with this switch will also be present at the parallel output 12 13 as already mentioned in Section 3 1 2 4 3 Audio phase metering 4 3 1 General The phase meter permits us to monitor the audio signal in phase This can be done in stereo or only left or right channel respectively 4 3 2 Left channel signal presence In the case that the equipment only disposes of a signal proceeding from left chann...

Страница 10: ... the equipment is stereo but out of phase the display of the phase meter will have the aspect as in figure 9 4 3 7 Monoaural signal presence out of phase In the case that the signal received is monoaural and out of phase the display of the phase meter will have the aspect as shown in figure 10 4 4 Headphones monitoring 4 4 1 Headphones connector The headphones connector 1 gives the opportunity to ...

Страница 11: ...d fuse s box 12 Parallel audio output for the selected right channel input 13 Parallel audio output for the selected left channel input 14 Audio input number 6 right channel 15 Audio input number 6 left channel 16 Audio input number 5 right channel 17 Audio input number 5 left channel 18 Audio input number 4 right channel 19 Audio input number 4 left channel 20 Audio input number 3 right channel 2...

Страница 12: ...Gain control Metering Phase meter Left Right by 25 led matrix in a 5 x 5 configuration Acoustic System Three way acoustic system Low Monoaural 1 compression magnet dynamic speaker Mid Stereo 2 compression magnet dynamic speaker High Stereo 2 piezo electric speakers Limiter Incorporated to protect speakers adjusted to the optimal output power Cross over frequencies Low Mid 600 Hz Mid High 4 KHz Fre...

Страница 13: ...rmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requi...

Отзывы: