7) Temperature Alarm Value
This parameter is configured the threshold value that alarm level for
temperature. When the current ambient temperature value is larger than this
configuration value, device will send a BASIC_SET = 0xFF to nodes
associated in group 3. If current temperature value is less than this value,
device will send a BASIC_SET = 0x00 to nodes associated in group 3.
Value = [Value] × 0.1(Celsius / Fahrenheit)
8) Led Indicate Disable
This parameter is configured the Led light on disable or enable.
‘1’ – Enable Led Blink when device detects a motion event.
‘0’ – Disable Led Blink. This configuration is not affect inclusion, exclusion and
reset.
9) Led Color For Motion Event Report
‘0’ – Disable.
‘1’ – Red.
‘2’ – Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
10) Led Color For Temperature Sensor Report
‘0’ – Disable.
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
11) Led Color For Light Sensor Report
‘0’ – Disable.
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
12) Led Color For Battery Report
‘0’ – Disable.
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
13) Led Color For Wakeup Notification Report
‘0’ – Disable.
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.
14) Temperature Scale Setting
Configure temperature sensor scale type, Temperature to report in Celsius or
Fahrenheit.
0 – Celsius (C).
1 – Fahrenheit (F).
15) Temperature Threshold Value to Report
Change threshold value for change in temperature to induce an automatic
report for temperature sensor. Scale is identical setting in Parameter No.20.
Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on
Parameter No.20) to induce automatic report or setting a value of 2 will be a
change of 0.2(C or F).
6) Basic Set Value Settings for Group 2
‘0’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion
event is triggered, send BASIC_SET = 0x00 to devices associated in
group 2 when motion event is cleared.
‘1’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
event is triggered, send BASIC_SET = 0xFF to devices associated in
group 2 when motion event is cleared.
‘2’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion
event is triggered.
‘3’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
event is triggered.
‘4’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion
event is cleared. ‘5’ – Send BASIC_SET = 0xFF to devices associated in
Group 2 when motion event is cleared.
[email protected]
www.aeotec.com
FCC ID: 2AOGIZWA005
Parameter Number
5
1
3
0 ~ 3
Size (Byte)
Available Settings
Default value
Parameter Number
6
1
0
0 ~ 5
Size (Byte)
Available Settings
Default value
Parameter Number
10
1
1
0 , 1
Size (Byte)
Available Settings
Default value
Parameter Number
11
1
2
0 ~ 8
Size (Byte)
Available Settings
Default value
Parameter Number
12
1
0
0 ~ 8
Size (Byte)
Available Settings
Default value
Parameter Number
13
1
0
0 ~ 8
Size (Byte)
Available Settings
Default value
Parameter Number
14
1
0
0 ~ 8
Size (Byte)
Available Settings
Default value
Parameter Number
15
1
0
0 ~ 8
Size (Byte)
Available Settings
Default value
Parameter Number
21
2
20
0 ~ 250
Size (Byte)
Available Settings
Default value
16) Light intensity Threshold Value to Report
Chang
22
2
100
0 ~ 10000
Size (Byte)
Available Settings
Default value
17) Temperature Sensor Report Interval
This parameter is configured the time interval for temperature sensor report.
This value is larger, the battery life is longer. And the temperature value
changed is not obvious. Unit: Second.
Parameter Number
23
2
3600
1 ~ 32767
Size (Byte)
Available Settings
Default value
18) Light Sensor Report Interval
This parameter is configured the time interval for light sensor report. This
value is larger, the battery life is longer. And the light intensity changed is not
obvious. Unit: Second.
Parameter Number
24
2
3600
1 ~ 32767
Size (Byte)
Available Settings
Default value
Temperature Offset Value
The current measuring temperature value can be add and minus a value by this
setting. The scale can be decided by Parameter Number 20.
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)
Parameter Number
30
2
0
-200 ~ 200
Size (Byte)
Available Settings
Default value
19) Light Intensity Offset Value
The current measuring light intensity value can be add and minus a value by
this setting.
Parameter Number
31
2
0
-1000 ~ 1000
Size (Byte)
Available Settings
Default value
20) Light Sensor Calibrated Coefficient
This configuration defines the calibrated scale for ambient light intensity.
Because the method and position that the sensor mounted and the cover of
sensor will bring measurement error, user can get more real light intensity by
this parameter setting. User should run the steps as blows for calibrating
1) Set this parameter value to default (Assumes the sensor has been added
in a Z- Wave Network).
2) Place a digital luxmeter close to sensor and keep the same direction,
monitor the light intensity value (Vm) which report to controller and record
it. The same time user should record the value (Vs) of luxmeter.
3) The scale calibration formula: k = Vm / Vs.
4) The value of k is then multiplied by 1024 and rounded to the nearest whole
number.
5) Set the value getting in 5) to this parameter, calibrate finished. For
example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667 k = 8.6667 *
1024 = 8874.7
≈
8875
The parameter should be set to 8875.
Parameter Number
100
2
1024
1 ~ 32767
Size (Byte)
Available Settings
Default value
*
COMMAND_CLASS_VERSION (V2)
*
COMMAND_CLASS_POWERLEVEL (V1)
*
COMMAND_CLASS_ASSOCIATION (V2)
*
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3)
*
COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
*
COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
*
COMMAND_CLASS_BATTERY (V1)
*
COMMAND_CLASS_WAKEUP (V2)
*
COMMAND_CLASS_NOTIFICATION (V8)
*
COMMAND_CLASS_SENSOR_BINARY (V2)
*
COMMAND_CLASS_SENSOR_MULTILEVEL (V7)
*
COMMAND_CLASS_CONFIGURATION (V1)
*
COMMAND_CLASS_SUPERVISION (V1)
All Supports Command Class
This device supports Z-Wave Command Class as follows:
*
COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
*
COMMAND_CLASS_SECURITY (V1)
*
COMMAND_CLASS_SECURITY_2 (V1)
*
COMMAND_CLASS_TRANSPORT_SERVICE (V2)
Parameter Number
20
EU/AU
US
1
1
1
0
0 , 1
0 , 1
Size (Byte)
Available Settings
Default value
Parameter Number
7
Size (Byte)
Available Settings
Default value
-400 ~ 1185 (Fahrenheit) 750 (Fahrenheit)
EU/AU
US
2
2
239 (Celsius)
-400 ~ 850 (Celsius)