7)   Temperature Alarm Value

This parameter is configured the threshold value that alarm level for 
temperature. When the current ambient temperature value is larger than this 
configuration value, device will send a BASIC_SET = 0xFF to nodes 
associated in group 3. If current temperature value is less than this value, 
device will send a BASIC_SET = 0x00 to nodes associated in group 3.
Value = [Value] × 0.1(Celsius / Fahrenheit) 

8)   Led Indicate Disable 

This parameter is configured the Led light on disable or enable.
‘1’ – Enable Led Blink when device detects a motion event.
‘0’ – Disable Led Blink. This configuration is not affect inclusion, exclusion and 

reset.

9)   Led Color For Motion Event  Report 

‘0’ – Disable. 
‘1’ – Red.
‘2’ – Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange. 

10)  Led Color For Temperature Sensor  Report 

‘0’ – Disable. 
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange. 

11)  Led Color For Light Sensor Report 

‘0’ – Disable. 
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange. 

12)  Led Color For Battery Report 

‘0’ – Disable. 
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange. 

13)  Led Color For Wakeup Notification  Report 

‘0’ – Disable. 
‘1’ – Red.
‘2’ –Green.
‘3’ – Blue.
‘4’ – Yellow.
‘5’ – Pink.
‘6’ – Cyan.
‘7’ – Purple.
‘8’ – Orange.

14)  Temperature Scale Setting 

Configure temperature sensor scale type, Temperature to report in Celsius or 
Fahrenheit.
0 – Celsius (C).
1 – Fahrenheit (F).

15)  Temperature Threshold Value to Report

Change threshold value for change in temperature to induce an automatic 

report for temperature sensor. Scale is identical setting in Parameter No.20.
Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on 

Parameter No.20) to induce automatic report or setting a value of 2 will be a 

change of 0.2(C or F).

6)   Basic Set Value Settings for Group 2 

‘0’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion 

event is triggered, send BASIC_SET = 0x00 to devices associated in 

group 2 when motion event is cleared.

‘1’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion 

event is triggered, send BASIC_SET = 0xFF to devices associated in 

group 2 when motion event is cleared.

‘2’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion 

event is triggered.

‘3’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion 

event is triggered.

‘4’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion 

event is cleared. ‘5’ – Send BASIC_SET = 0xFF to devices associated in 

Group 2 when motion event is cleared.

[email protected]
www.aeotec.com

FCC ID: 2AOGIZWA005

Parameter Number

5

1

3

0 ~ 3

Size (Byte)

Available Settings

Default value

Parameter Number

6

1

0

0 ~ 5

Size (Byte)

Available Settings

Default value

Parameter Number

10

1

1

0 , 1

Size (Byte)

Available Settings

Default value

Parameter Number

11

1

2

0 ~ 8

Size (Byte)

Available Settings

Default value

Parameter Number

12

1

0

0 ~ 8

Size (Byte)

Available Settings

Default value

Parameter Number

13

1

0

0 ~ 8

Size (Byte)

Available Settings

Default value

Parameter Number

14

1

0

0 ~ 8

Size (Byte)

Available Settings

Default value

Parameter Number

15

1

0

0 ~ 8

Size (Byte)

Available Settings

Default value

Parameter Number

21

2

20

0 ~ 250

Size (Byte)

Available Settings

Default value

16)  Light intensity Threshold Value to Report

Chang

22

2

100

0 ~ 10000

Size (Byte)

Available Settings

Default value

17)  Temperature Sensor Report Interval

This parameter is configured the time interval for temperature sensor report. 
This value is larger, the battery life is longer. And the temperature value 
changed is not obvious. Unit: Second.

Parameter Number

23

2

3600

1 ~ 32767

Size (Byte)

Available Settings

Default value

18)  Light Sensor Report Interval

This parameter is configured the time interval for light sensor report. This 
value is larger, the battery life is longer. And the light intensity changed is not 
obvious. Unit: Second.

Parameter Number

24

2

3600

1 ~ 32767

Size (Byte)

Available Settings

Default value

 Temperature Offset Value

The current measuring temperature value can be add and minus a value by this 
setting. The scale can be decided by Parameter Number 20.
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)

Parameter Number

30

2

0

-200 ~ 200

Size (Byte)

Available Settings

Default value

19)  Light Intensity Offset Value

The current measuring light intensity value can be add and minus a value by 
this setting.

Parameter Number

31

2

0

-1000 ~ 1000

Size (Byte)

Available Settings

Default value

20)   Light Sensor Calibrated Coefficient 

This configuration defines the calibrated scale for ambient light intensity. 
Because the method and position that the sensor mounted and the cover of 
sensor will bring measurement error, user can get more real light intensity by 
this parameter setting. User should run the steps as blows for calibrating
1)  Set this parameter value to default (Assumes the sensor has been added 

in a Z- Wave Network).

2)  Place a digital luxmeter close to sensor and keep the same direction, 

monitor the light intensity value (Vm) which report to controller and record 
it. The same time user should record the value (Vs) of luxmeter.

3)  The scale calibration formula: k = Vm / Vs.
4)  The value of k is then multiplied by 1024 and rounded to the nearest whole 

number.

5)  Set the value getting in 5) to this parameter, calibrate finished. For 

example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667 k = 8.6667 * 
1024 = 8874.7 

 8875

The parameter should be set to 8875.

Parameter Number

100

2

1024

1 ~ 32767

Size (Byte)

Available Settings

Default value

COMMAND_CLASS_VERSION (V2)

COMMAND_CLASS_POWERLEVEL (V1)

COMMAND_CLASS_ASSOCIATION (V2)

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (V3)

COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)

COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)

COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)

COMMAND_CLASS_BATTERY (V1)

COMMAND_CLASS_WAKEUP (V2)

COMMAND_CLASS_NOTIFICATION (V8)

COMMAND_CLASS_SENSOR_BINARY (V2)

COMMAND_CLASS_SENSOR_MULTILEVEL (V7)

COMMAND_CLASS_CONFIGURATION (V1)

COMMAND_CLASS_SUPERVISION (V1)

All Supports Command Class

This device supports Z-Wave Command Class as follows:

COMMAND_CLASS_ZWAVEPLUS_INFO    (V2)

COMMAND_CLASS_SECURITY (V1)

COMMAND_CLASS_SECURITY_2 (V1)

COMMAND_CLASS_TRANSPORT_SERVICE (V2)

Parameter Number

20

EU/AU

US

1

1

1

0

0 , 1
0 , 1

Size (Byte)

Available Settings

Default value

Parameter Number

7

Size (Byte)

Available Settings

Default value

-400 ~ 1185 (Fahrenheit) 750 (Fahrenheit)

EU/AU

US

2
2

239 (Celsius)

-400 ~ 850 (Celsius)