![Aeotec Recessed Door Sensor 7 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/aeotec/recessed-door-sensor-7/recessed-door-sensor-7_manual_2861224007.webp)
AEOTEC Engineering Specification
Page 3
Security Class
Non-Security, S0, S2 Unauthenticated, and S2 Authenticated
SmartStart Compatible
Support. After powering on, SmartStart is auto activ ated if it ’s out of the Z-Wave network.
Over The Air (OTA)
Support. Firmware can be updated via RF.
Multi Channel Device
No
Association
Support. Refer to Section 4.7 Association Group Info.
Factory Reset
Support. Refer to Section 3.6 How to factory reset.
Power-down Memory
Support. All command settings will stay unchanged even power down.
Timed battery report
Support. Refer to Configuration Parameter 101.
Low battery warning
Support. Refer to Configuration Parameter 90.
Sensor State Report
Support. When Magnet is away or near, send out notification via Group 1 .
Control other device
Support. When Magnet is away or near, control other Z -Wave device directly via Group 2.