Advanced functions.

Changing batteries.

Removing your MultiSensor from a Z-Wave network.

Monitoring motion.

Waking up your Multisensor.

Resetting your MultiSensor.

Adjusting the sensitivity of your MultiSensor .

 Monitoring temperature, humidity and luminance.

If you’re using a Z-Stick:

If you’re using a Minimote:

Your MultiSensor has built in battery level detection. It will automatically report its 

battery level to the associated control point throughout its life until the battery is fully 

drained and needs replacing. The battery status will often be displayed in the user 

interface of the control point.

When used properly in an optimised Z-Wave network, your MultiSensor can be 

powered by batteries for 12 months before battery replacement is necessary.

Recommendation

: For networks which do not offer a method to display the battery 

level of your MultiSensor, it is recommended that the sensor be tested occasionally 

to ensure that the batteries still hold enough charge to operate. Batteries naturally 

lose their charge over time.

1. If your Z-Stick is plugged into a gateway or a computer, unplug it.

2. Take your Z-Stick to your MultiSensor .

3. Press and hold the Action Button on your Z-Stick for 3 seconds and then release.

4. Press the Z-Wave Button on your MultiSensor .

5. If your MultiSensor has been successfully removed from your network, its LED will 

    blink when you press the Z-wave Button. If the removal was unsuccessful, the LED 

    will stay solid for a few seconds when you press the Z-wave Button.

6. Press the Action Button on the Z-Stick to take it out of removal mode.

1. Take your Minimote to your MultiSensor.

2. Press the Remove Button on your Minimote.

3. Press the Z-wave Button on your MultiSensor .

4. If your MultiSensor has been successfully removed from your network, its LED will 

    blink when you press the Z-wave Button. If the removal was unsuccessful, the LED 

    will stay solid for a few seconds when you press the Z-wave Button.

5. Press any button on your Minimote to take it out of removal mode.

Your MultiSensor can be removed from your Z-Wave network at any time. You’ll 

need to use your Z-Wave network’s main controller to do this and the following 

instructions tell you how to do this using Aeotec by Aeon Labs’ Z-Stick and Minimote 

controllers. If you are using other products as your main Z-Wave controller, please 

refer to the part of their respective manuals that tells you how remove devices from 

your network.

The MultiSensor can send Basic Set Command to association group 1, which 

is setup via the Association Command Class, when the Motion Sensor detects 

movement to control the associated devices to “OPEN” state. After 4 minutes by 

default, if the Motion Sensor is not triggered again, the MultiSensor will send Basic 

Set Command to these devices to set them to their “CLOSE” state. However, if the 

Motion Sensor is triggered again in 4 minutes, the MultiSensor will reset the timing 

and start timing again.

The 4 minutes delay time can be changed through the usage of Z-Wave command 

built into Z-Wave certified control points. (The specific Z-Wave command supporting 

this function is Configuration Command Class) Please consult the operation manual 

for these control points for specific instructions on setting the MultiSensor.

If your MultiSensor is battery powered, you will need to ensure that it is active when 

configuring it. To do this, press and hold its Z-Wave Button for 3 seconds and then 

release it. Your MultiSensor’s LED should now be solid to indicate that it is active.

When you are done configuring or communicating with your MultiSensor, you can 

put it back into sleep mode to conserve battery power. To do this, press and hold its 

Z-Wave button for 3 seconds and then release it. Your MultiSensor’s LED should 

now be off to indicate that it is asleep.

At some stage or your primary controller is missing or inoperable, you may also wish 

to reset all of your MultiSensor’s settings to their factory defaults. To do this, press 

and hold the Z-Wave Button for 20 seconds and then release it. Your MultiSensor 

will now be reset to its original settings, and the LED will stay solid for 2 seconds and 

then turn off as a confirmation.

Power Supply: USB DC 5V or battery power(4×AAA batteries). 

Operating Temperature: -10    to 60   .

Measured Temperature Range: -10    to 50   . Accuracy: ±1    .

Humidity Range: 20% to 80%. Accuracy: ±5% (at 25    ).

Lighting: 0 to 1000 LUX.

Motion Sensitivity: 3 to 5 meters.

Water Proofing: IP42.

Wireless Range: Up to 500 feet/150 metres outdoors.

Turn the Sensitivity Knob in a clockwise direction to increase sensitivity and counter-

clockwise to decrease sensitivity.

Your MultiSensor can report temperature, humidity, and luminance across a Z-Wave 

network when requested. If this function is supported by a controller, generally a 

gateway, the data will be displayed within its interface. The specific Z-Wave 

commands for the support of monitoring is the Multilevel Sensor Command Class 

and Multi Channel Command Class. Automatic reports are sent to association group 

1, which is setup via the Association Command Class. Please consult the controller’s 

operation manual for specific instructions on setting your MultiSensor.

Setting automatic report flags.

Parameter 101-103 [4 byte decimal] can be configured through your gateway in case 

the default settings of your MultiSensor are not what you desire.

The table above shows a decimal representation of all flags that can be set on 

parameter 101-103 to report specific data.

Example use of the report table.

For example, if you want to report only the temperature and light sensor you would 

add 32 + 64 and set the sum (96) to parameter 101, 102, or 103.
As another example, if you want to report only the light sensor and battery, you would 

add 1 + 128, then set the sum (129) to parameter 101, 102, or 103.
And if you want to report all of the sensors, you would add the whole table together 

and set the sum (225) to parameter 101, 102, or 103.

Setting an automatic report interval.

Parameter 111-113 [4 byte decimal] can be configured through your gateway in case 

the default settings of your MultiSensor are not what you desire.
Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will 

set the interval for Group 2 (parameter 102), and parameter 113 will set the interval 

for Group 3 (parameter 103).
As an example, you have set parameter 101 to 225 which will report all of the 

sensors, and you want to report it every 1800 seconds. Set parameter 111 to 1800 to 

accomplish this.

Action

 

Button

lag

Light Sensor

Humidity Sensor

Battery Sensor

Temperature Sensor

128

64
32

1

Technical specifications. 

C

C

C

C

C

C

Warranty.

6

Aeon Labs warrants to the original purchaser of Products that for the Warranty Period 

(as defined below), the Products will be free from material defects in materials and 

workmanship. The foregoing warranty is subject to the proper installation, operation 

and maintenance of the Products in accordance with installation instructions and 

the operating manual supplied to Customer. Warranty claims must be made by 

Customer in writing within thirty (30) days of the manifestation of a problem. Aeon 

Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, 

replace or correct any such defect that was present at the time of delivery, or to 

remove the Products and to refund the purchase price to Customer. 
The "Warranty Period" begins on the date the Products is delivered and continues for 

12 months. 
Any repairs under this warranty must be conducted by an authorized Aeon Labs 

service representative and under Aeon Labs' RMA policy. Any repairs conducted by 

unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, civil or 

military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse, 

misapplication, storage damage, negligence, electrical power problems, or 

modification to the Products or its components. 
Aeon Labs does not authorize any person or party to assume or create for it any 

other obligation or liability in connection with the Products except as set forth herein. 
Aeon Labs will pass on to Customer all manufacturers’ Material warranties to the 

extent that they are transferable, but will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products, 

and insure the shipment or accept the risk of loss or damage during such shipment 

and transportation. Aeon Labs will ship the repaired or replacement products to 

Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' affiliates, 

shareholders, directors, officers, employees, contractors, agents and other 

representatives harmless from all demands, claims, actions, causes of action, 

proceedings, suits, assessments, losses, damages, liabilities, settlements, 

judgments, fines, penalties, interest, costs and expenses (including fees and 

disbursements of counsel) of every kind (i) based upon personal injury or death or 

injury to property to the extent any of the foregoing is proximately caused either by a 

defective product (including strict liability in tort) or by the negligent or willful acts or 

omissions of Customer or its officers, employees, subcontractors or agents, and/or 

(ii) arising from or relating to any actual or alleged infringement or misappropriation 

of any patent, trademark, mask work, copyright, trade secret or any actual or alleged 

violation of any other intellectual property rights arising from or in connection with the 

products, except to the extent that such infringement exists as a result of Aeon Labs' 

manufacturing processes. 

IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, 

SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, 

OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN 

CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH 

DAMAGES.  AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE 

OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF 

THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF 

WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED 

TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE 

FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED.  

ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE 

OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN 

THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN 

THE EVENT OF NONDELIVERY. 

THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 

INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

FCC NOTICE (for USA)

This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions:

THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE 

CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS 

COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN 

WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER.

This device may not cause harmful interference, and        

This device must accept any interference received, including interference that 

may cause undesired operation. This equipment has been tested and found to 

comply with the limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used 

in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur 

in a particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the equipment 

off and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:    

1

2

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit   different from that to which 

the receiver is connected.

Consul the dealer or an experienced radio/TV technician for help.

Do not dispose of electrical appliances as unsorted municipal waste, use 

separate collection facilities.

Contact your local government for information regarding the collection systems 

available.

Warning