Aeotec Door / Window Sensor 7 Скачать руководство пользователя страница 7

18/06/2021

Aeotec Door Window Sensor 7 Basic guide : Aeotec Help Desk

https://help.aeotec.com/support/solutions/articles/6000230382-door-window-sensor-7-basic-user-guide-zwa011-zwa041-

7/9

Remove the cover of Door / Window Sensor 7

Press and hold tamper switch for 5 seconds until the red LED blinks.

Release the tamper switch

Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.

Association Groups.

Association groups allow Door Window Sensor 7 to directly control Z-Wave devices without the use of a Z-Wave
Controller to maximize communication efficiency. 

Group Number Max Nodes Description
1

5

Lifeline 

2

5

Control devices when a magnet or external dry
contacts trips

 

3

5

Sends our alarm message when magnet controlled or
external dry sensor trips.

 

4

5

Sends alarm messages when tamper is tripped

 

Parameter Configurations.

Parameter 3: Door/Window State.

This parameter allows setting Door / Window Sensor 7 state when the magnet is close to the sensor.
Size: 1 Byte, Default Value: 0

Setting Description

0

closed when the magnet is near

1

opened when the magnet is near

Parameter 4: Visual LED Indications.

This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.
Size: 1 Byte, Default Value: 7, Range: 0 - 7

Setting Description

0

no indications

1

indication of opening/closing status change

2

indication of wake up (1 x click or
periodical)

4

indication of device tampering

Parameter 5: Range test after double click.

Allows enabling the activation of Z-Wave range test with double click of a Tamper Switch 2.
Size: 1 Byte, Default Value: 0

Setting Description

0

Disable

1

Enable

Parameter 6: Group 2 Association Triggers.

Содержание Door / Window Sensor 7

Страница 1: ...chnology and S2 framework You can find out more about Door Window Sensor 7 https aeotec com z wave door window sensor Basic by following that link To see whether Door Window Sensor 7 Basic is known to...

Страница 2: ...d responsible for any loss or damage resulting from not following any instructions in this guide or in other materials Keep the product and batteries away from open flames and extreme heat Avoid direc...

Страница 3: ...h the holes inside the battery compartment If the tilt detection on a window only normal windows no roof windows shall be used the sensor device must be placed on the moving part of the window and the...

Страница 4: ...en from the mark on the Door Windows Sensor 7 Basic Adding your Door Windows Sensor 7 Basic to Z Wave network SmartStartInclusion YoucanusethismethodofinclusiononlyifyourZ Wavegateway controller hubsu...

Страница 5: ...f the inclusion it lights up once before it goes out 4 Close the cover Note Closing the cover is important If the housing is not closed the sensor is permanently awake Only when the cover is closed do...

Страница 6: ...nd a wake up notification In order to send your sensors new configuration commands from your Z Wave controller or gateway it will need to be woken up 1 Wake Up the device by removing the cover 2 The h...

Страница 7: ...ontrolled or external dry sensor trips 4 5 Sends alarm messages when tamper is tripped Parameter Configurations Parameter 3 Door Window State This parameter allows setting Door Window Sensor 7 state w...

Страница 8: ...ription 0 On 1 Off 2 On and Off Parameter 8 Values of ON command frame sent to Group 2 Association The value of 0 turns OFF the device 255 turns it On In the case of associating the Dimmer or Roller S...

Страница 9: ...Value 0 Setting Description 0 32400 Time in seconds Parameter 13 Reporting tamper alarm cancellation Reporting cancellation of tamper alarm to the controller and 3rd Association Group Size 1 Byte Def...

Отзывы: