![Aeotec Door / Window Sensor 7 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/aeotec/door-window-sensor-7/door-window-sensor-7_user-manual_2861206007.webp)
18/06/2021
Aeotec Door Window Sensor 7 Basic guide : Aeotec Help Desk
https://help.aeotec.com/support/solutions/articles/6000230382-door-window-sensor-7-basic-user-guide-zwa011-zwa041-
7/9
.
Remove the cover of Door / Window Sensor 7
.
Press and hold tamper switch for 5 seconds until the red LED blinks.
.
Release the tamper switch
.
Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.
Association Groups.
Association groups allow Door Window Sensor 7 to directly control Z-Wave devices without the use of a Z-Wave
Controller to maximize communication efficiency.
Group Number Max Nodes Description
1
5
Lifeline
2
5
Control devices when a magnet or external dry
contacts trips
3
5
Sends our alarm message when magnet controlled or
external dry sensor trips.
4
5
Sends alarm messages when tamper is tripped
Parameter Configurations.
Parameter 3: Door/Window State.
This parameter allows setting Door / Window Sensor 7 state when the magnet is close to the sensor.
Size: 1 Byte, Default Value: 0
Setting Description
0
closed when the magnet is near
1
opened when the magnet is near
Parameter 4: Visual LED Indications.
This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life.
Size: 1 Byte, Default Value: 7, Range: 0 - 7
Setting Description
0
no indications
1
indication of opening/closing status change
2
indication of wake up (1 x click or
periodical)
4
indication of device tampering
Parameter 5: Range test after double click.
Allows enabling the activation of Z-Wave range test with double click of a Tamper Switch 2.
Size: 1 Byte, Default Value: 0
Setting Description
0
Disable
1
Enable
Parameter 6: Group 2 Association Triggers.