![Aeotec AEOEZW132 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/aeotec/aeoezw132/aeoezw132_manual_2861285007.webp)
7-11-2020
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
7/10
Setting
Description
1
Send Meter Report of voltage (V)
2
Send Meter Report of current (A)
4
Send Meter Report of wattage (W)
8
Send Meter Report of energy (kWh)
256
Send Multi Channel Meter Report of wattage (W) on Channel 1
512
Send Multi Channel Meter Report of wattage (W) on Channel 2
2048
Send Multi Channel Meter Report of energy (kWh) on Channel 1
4096
Send Multi Channel Meter Report of energy (kWh) on Channel 2
65536
Send Multi Channel Meter Report of voltage (V) on Channel 1
131072
Send Multi Channel Meter Report of voltage (V) on Channel 2
524288
Send Multi Channel Meter Report of current (A) on Channel 1
1048576
Send Multi Channel Meter Report of current (A) on Channel 2
Parameter 110: Set parameter 111-113 to default value.
Set parameter 111-113 to default value.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Reset the parameter 111-113
Parameter 111: Set the interval of automatic report for Report group 1.
Set the interval of automatic report for Report group 1.
Size: 4 Byte, Default Value: 10
Setting
Description
1 - 2147483647
The range of interval time is 1 to 2147483647.
Parameter 112: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 2.
Size: 4 Byte, Default Value: 600
Setting
Description
1 - 2147483647
The range of interval time is 1 to 2147483647.
Parameter 113: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 3.
Size: 4 Byte, Default Value: 600
Setting
Description
1 - 2147483647
The range of interval time is 1 to 2147483647.
Parameter 120: Configure the external switch mode for S1.
Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Enter automatic identification mode
1
2-state switch mode
2
3 way switch mode
3
Momentary push button mode
Parameter 121: Configure the external switch mode for S2.
Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0