6-11-2019
Radiator Thermostat user guide : Aeotec Group
https://aeotec.freshdesk.com/support/solutions/articles/6000224131-radiator-thermostat-user-guide
10/12
Inverts the LCD orientation.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Normal orientation
1
LCD content inverted
Parameter 2: LCD Timeout
Configures the timeout of the LCD.
Size: 1 Byte, Default Value: 0
Setting
Description
0
LCD always on
5 - 30
LCD timeout in seconds
Parameter 3: Backlight
Enables or disables the LCD-Backlight.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Backlight disabled
1
Backlight enabled
Parameter 4: Battery report
Enables or disables unsolicited battery reporting once a day.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Battery reporting disabled
1
Battery reporting enabled
Parameter 5: Measured temperature report
Reports the measured room temperature on change.
Size: 1 Byte, Default Value: 5
Setting
Description
0
Reporting disabled
1 - 50
Reporting Delta in 1/10 Celcius
Parameter 6: Valve percentage report
Reports the valve percentage on change.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Reporting disabled
1 - 100
Reporting Delta in percent
Parameter 7: Window open detection